1. Catalogs
  2. ASTRON
  3. PRODUCT SPECIFICATIONS
video corpo

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS
1 / 28 PagesView full catalog

PRODUCT SPECIFICATIONS

Product catalog summary
General Overview

Origins of Astron
The Astron system is produced by Lindab S.A. in Luxembourg, Lindab Buildings s.r.o in the Czech Republic, and Lindab Buildings LLC in Russia.

The Product
Astron includes a variety of components such as primary and secondary framing, roof and wall cladding, thermal insulation, and accessories like doors and windows. Crane beams and mezzanines are also available.

The Range of Astron
Astron buildings are customizable with configurations like AZM1, AZM2, AZM3, AZM4, AS, AE, AL, AP, and AT, each with specific characteristics and limitations.

Mezzanines
Mezzanines can be integrated into buildings, available in metal decking, precast concrete panels, or hollow core concrete slabs.

Terms Defining Astron Buildings
Key terms include steel line, span, length, and eave height.

Common Dimensions
Bay spacing ranges from 5 to 12 meters, with specific dimensions for each building type.

Static Calculations, Drawings, and Guarantees
Erection drawings and calculation notes are provided, with guarantees detailed in the "Terms and Conditions" document.
Design Calculations

General
Design follows Eurocodes and Nationally Determined Parameters, with local legal adjustments.

Loads Taken into Account
Loads include dead load, snow/sand load, wind load, and additional loads like occupancy and crane loads, following national codes.
The Structure

Terminology
Primary framing transfers exterior loads to foundations, while secondary framing supports roof and wall sheeting.

Stability
Stability is ensured through frame rigidity and wind bracing, with specific requirements for mezzanines and crane rail beams.

Material Specifications
Materials include S355 J2+N steel for primary framing, S235JRH for pipe columns, and S390 GD + Z 275 for cold-formed components. High-strength bolts are used for connections.

Corrosion Protection
Primary framing components are shot blasted and coated with rust protection, with various colors and protection levels available.
Primary Framing
Components can be hot-dipped galvanized for special applications. Anchor bolts are unprimed and unpainted, while bracing rods have a 45-micron metallic coating.
Secondary Framing
Purlins and girts in Z and C profiles are made from galvanized material per EN 10326, with 275 g/m² zinc coating.
Wall Sheeting and Roofing
Astron offers five types of wall sheeting and three types of roof sheeting, which can be combined based on aesthetics and technical needs. Inside wall sheeting can be perforated for acoustical absorption.
Wall and Roof Systems
LPA 900 Wall Type: Ribbed steel panels with superpolyester coatings.
POLAR SA Wall Type: Sandwich panels with polyurethane foam insulation.
SINUTEC Wall System: Sinusoidal steel panels installed horizontally.
SINUTHERM Wall System: High wave corrugated sandwich panels.
LPR1000 Roof System: Steel ribbed panels.
LMR600 Roof System: Factory roll-formed panels with a double-lock seam.
POLAR SR Roof System: Sandwich panels with polyurethane foam insulation.
Material Specifications
Stainless steel screws and tape sealers are used, with specific distributions based on panel type.
Double Skin Roof System (DSR)
Consists of an inner panel fixed to purlins and an outer skin fitted to omega spacers and rails, with ASTROTHERM insulation in between.
Inner Panel LPS1000
Made from steel quality S550 GD or S350 GD, with various finishes available.
Inner Perforated Panel LPG1000
Similar to LPS1000 but perforated for acoustical applications.
Bridge System
An insulation spacing system designed to minimize cold bridging.
LPI1200 – Interior Sheeting
Ribbed steel panel used for interior sheeting.
ASTROTHERM – Thermal Insulation
Flexible fiberglass blanket with a vapor barrier, available in various thicknesses.
Accessories
Astron provides a range of accessories for roof and wall systems, including windows, doors, skylights, and safety systems certified according to EN13374 and EN 795.
See more

Catalog excerpts

PRODUCT SPECIFICATIONS-1

Product specifications

 Open the catalog to page 1
PRODUCT SPECIFICATIONS-3

Origins of Astron The name Astron defines a system of metal buildings made from elements which are fabricated by the company Lindab S.A. based in Diekirch, in the Grand Duchy of Luxembourg or by the company Lindab Buildings s.r.o based in Prerov (Czech Republic) or by the Company Lindab Buildings LLC based in Yaroslavl (Russia). The Product Astron incorporates all the elements of the framework; primary and secondary framing (including bolts, clips, flange bracing, etc.), roof and wall cladding (including screws, closures, sealers, flashings, etc.) the thermal insulation ASTROTHERM (see sub-heading...

 Open the catalog to page 3
PRODUCT SPECIFICATIONS-4

Astron buildings allow the integration of mezzanines; these can be installed in any part or over the whole building and generally have only one floor. Several mezzanine systems are available: metal decking, precast concrete panels, hollow core concrete slaps available. 1.5. Terms defining Astron buildings • The steel line of an Astron building is, by definition, the line representing the outer surface of the secondary framing (purlins and girts, in principle). • The span of an Astron building is the distance between the sidewall steel lines of the building. • The length of a building is the distance...

 Open the catalog to page 4
PRODUCT SPECIFICATIONS-5

DESIGN CALCULATIONS Structural elements of Astron buildings are designed by the engineering teams and correspond to the requirements of the national standards. All European countries involved in the “European Implementation Timetable” use so called Eurocodes. The Eurocodes were implemented between 2001 and 2007 as 58 individual parts. These parts were published under the 10 area headings referred to as “Eurocode 0” to Eurocode 9”. The formal prefixes for the codes are “EN 1990” to “EN 1999”. The national implementation comprises the full, unaltered text of the particular Eurocode preceded by...

 Open the catalog to page 5
PRODUCT SPECIFICATIONS-6

Terminology A general distinction is made between the primary and secondary framing, as follows: The primary framing consists of all of the structural elements which transfer the exterior loading to the foundations. Therefore it includes the intermediate frames, the rafter and columns of the endwall, jackframes and the supported rafters, wind portal frames, crane rail beams, wind bracing, and all of the various components usually associated with the above mentioned, e.g., anchor bolts, crane brackets. Also included under "primary framing" are items such as mezzanines beams and welded beams in...

 Open the catalog to page 6
PRODUCT SPECIFICATIONS-7

3.2.4. Mezzanines The structure of the mezzanines is fabricated out of hot-rolled beams or welded sections, partially supported by the framing of the building, and/ or by additional columns. The mezzanines are stabilized by their connections to the building frames, or by an independent wind bracing system. 3.2.5. Crane rail beams for bridge cranes The crane rail beams are made from hot-rolled profiles; generally they are supported by crane brackets. The crane rail beams can be made as simple supported or as continuous beams. 3.2.6. Stability of endwalls As a general rule the endwall frames consist...

 Open the catalog to page 7
PRODUCT SPECIFICATIONS-8

3.3. Material specifications 3.3.1. Built up-welded primary framing members The welded elements which are used principally for the primary framing are made from S355 J2+N steel conforming to EN 10025, part 2. Its main properties, for thicknesses lower than 16 mm, are: ■ Yield strength: 355 N/mm2 ■ Elongation at rupture: 22% minimum The welding of the elements is carried out in accordance with DIN 18800, part 7, resp. EN 1090-2 if introduced officially.. The web to flange welding is done automatically by submerged arc welding (under flux). The welding rod and the flux conform with norm EN iSo...

 Open the catalog to page 8
PRODUCT SPECIFICATIONS-9

The connection of purlins and girts to each other and to the primary framing is made using M12 bolts of steel quality minimum 4.6 conforming to EN ISO 4017 and 4018 except for the dimensions of the head and the nut conforming to the DIN 558 and 933. 3.3.6. Bracing The steel rods which act as ties in the windbracing are made from steel quality 6.8 for 0 18 & 24, and 5.8 for 0 30. The threads on the rods are produced by rolling. Three diameters of rods are used to produce M18, M24 and M30 threads respectively. 3.3.7. Anchor bolts The anchor bolts are produced from the same material as the wind...

 Open the catalog to page 9
PRODUCT SPECIFICATIONS-10

WALL SHEETING AND ROOFING General Astron supplies five types of wall sheeting and three of roof sheeting. The various roof and wall types are generally combinable. The choice of one or other combination will depend on criteria such as aesthetics, technical considerations, etc. In addition, Astron offers inside wall sheeting which can be perforated to improve acoustical absorption. There are also two roof panels specially designed for built-up roof construction: - Multitec - with purlins - Spacetec - without purlins. 4.1.1. Description Ribbed steel panel, colour-coated, produced by cold roll forming....

 Open the catalog to page 10
PRODUCT SPECIFICATIONS-11

Distribution of screws: ■ For fixation to girts: 1 per rib, i.e. 3 per panel ■ For stitching panel sidelaps: 1 per 500 mm 4.1.4. The LPA wall The first girt is located 2.2 m from the ground with successive girts placed at intervals of not more than 1.8 m. One can place ASTROTHERM insulation (See sub-heading below) between the girts and the LPA900 sheeting. One can also fix interior LPI1200 or LPG1000 sheeting (See sub-headings below) on the other side of the girt resulting in a double skin wall and providing an attractive interior finish, added protection to the insulation and acoustical correction....

 Open the catalog to page 11
PRODUCT SPECIFICATIONS-12

Screw specification: ■ Lengths: ■ Diameter: ■ Material: Distribution of screws: ■ Fixed to girts: 4.3.4. POLAR SA walls Double threaded self-drilling screws according to panel thickness 6.3 mm galvanized hardened steel Depending on panel type The distribution of the girts is a function of the thickness of the sandwich panel and the local design loads. POLAR walls offer a high degree of insulation, as well as an attractive interior/exterior finish. 4.4. SINUTEC wall system (PT) 4.4.1. Description Sinusoidal steel panel, colour-coated, produced by cold roll forming. The principal characteristics...

 Open the catalog to page 12

All ASTRON catalogs and technical brochures

  1. Car Parks

    12  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.