DMX512 Interface LXU03
12Pages

{{requestButtons}}

Catalog excerpts

DMX512 Interface LXU03 - 1

LXU03 DMX512 INTERFACE Operating Instructions LIGHTING

Open the catalog to page 1
DMX512 Interface LXU03 - 3

PREFACE PRECAUTIONS The LXU03 is DMX512 to ASTEL protocol multi-light converter with 3 outputs to control 3 groups of RGB multi-color lights of METEOR series with built-in ASTEL protocol. The DMX512 control of single-color lights METEOR series is enabled by using the PWM dimmer LDU13 with built-in ASTEL protocol. FEATURES 3 Control Outputs DIP-switch Programmable Low Speed Mode Wide Range Power Supply Low Power Consumption Polarity Protection Transient Protection Short Circuit Output Protection Simple Installation 3 The DMX512 Interface LXU03 has to be installed and used in accordance with...

Open the catalog to page 3
DMX512 Interface LXU03 - 4

CONTROLS AND CONNECTORS DMX512 Interface LXU03 5 P CH - 2 8 9 SERIAL NUMBER: ASTEL MARINE P CH - 3 7 4 P CH - 1 6 3 3 J2 1 2 CONTROL DC IN 1 2 (1) CONTROL The 3-pole terminal block connector to connect DMX512 line. (2) DC IN Terminal-block connector to connect 12-24Vdc power supply. (3) J2 Jumper for termination of DMX512/RS485 line. (4) CH-1 Control output to connect the +Control (P) and GND Control (-) wires of multi-color RGB lights Meteor series or PWM dimmer LDU13. (5) CH-2 Control output to connect the +Control (P) and GND Control (-) wires of multi-color RGB lights Meteor series or...

Open the catalog to page 4
DMX512 Interface LXU03 - 5

INSTALLATION The DMX512 Interface LXU03 kit consists of the following components: DMX512 Interface LXU03 2 x cable gland M12 Operating Instructions with Declaration of Conformity and Warranty conditions The LXU03 has to be installed on a suitable location. Avoid the installation in extremely hot places and near appliances generating strong magnetic fields. The installation has to be realized by a qualified personnel. Note: The main DC power supply has to be switched off before installation. D D+ GND DMX512 LINE ASTEL P CH - 3 P CH - 2 CONTROL GND CONTROL GND 1 2 CONTROL 3 CONTROL GND P CH -...

Open the catalog to page 5
DMX512 Interface LXU03 - 6

SET-UP The DMX512 Interface LXU03 set-up is enabled by adjusting the DIP-switches SW1, SW2 and SW3: SW1 – SW2 – SW3 switches 1-2-3-4-5-6-7-8 OFF-OFF-OFF-OFF-OFF-OFF-OFF-OFF ON -OFF-OFF-OFF-OFF-OFF-OFF-OFF ON –ON -OFF-OFF-ON -OFF-ON -ON OFF-ON –ON –ON –ON –ON –ON -ON ON –ON –ON –ON –ON –ON –ON -ON 0 1 211 254 255 SW1 – to set-up the mode of operation and programming SW1 switches 1-4 5 6 7 8 VALUE FUNCTION Mode of operation not used not used Programming trigger Programming mode SW2 – to set-up the communication parameters SW3 – to set-up the communication parameters The set-up procedure: 1....

Open the catalog to page 6
DMX512 Interface LXU03 - 7

CH-1 DMX address The DMX address is 9 bit long. The LSB part is in SW3 - lowest 8 bits , MSB part is SW2 – the 9th bit This address is used as base address for CH-1 in DMX packet. CH-2 DMX offset address This is the offset address of the CH-2. The address for CH-2 in DMX packet is the sum of the CH1 DMX address and CH2 offset. CH-3 DMX offset address This is the offset address of the CH-3. The address for CH-3 in DMX packet is the sum of the CH-1 DMX address and CH-2 offset CH-1 number of addressable lights This defines how the CH-1 is acting. There are two basic modes: -non addressable -...

Open the catalog to page 7
DMX512 Interface LXU03 - 8

CH-2 data type As described for the CH-1. CH-3 data type As described for the CH-1. Set default Sets the parameters to their default values: Parameter DMX address DMX CH2 offset DMX CH3 offset CH1 number CH2 number CH3 number CH1 type CH2 type CH3 type Value 0 0 0 0 0 0 2 2 2 Programming the light address The set up procedure: 1. Connect the light to the DMX512 interface LXU03 – CH-1 2. Connect the light to the power supply 3. Switch-on the light – the light must light! 4. Switch-off the light – the light must NOT light! 5. Disconnect the light from power supply 6. Connect the DMX interface...

Open the catalog to page 8
DMX512 Interface LXU03 - 9

55 APPEARANCE 21 80 21 53 23 TECHNICAL SPECIFICATIONS Input voltage Consumption Operating temperature Casing Protection Dimensions Weight 12-24 Vdc max. 50 mAdc -10C - +50C ABS IP 65 max. 106x122x55.5mm 0.2 kg Design and specifications subject to change without notice. 9 30

Open the catalog to page 9
DMX512 Interface LXU03 - 10

WARRANTY 1. The equipment manufactured by ASTEL d.o.o. is warranted to be free from defects in workmanship and materials under normal use and service. 2. This Warranty is in effect for of two years from the date of purchase by the user. Proof of purchase must be included, to establish that it is inside the warranty period. 3. This Warranty is transferrable and covers the product for the specified time period. 4. In case any part od the equipment proves to be defective, other than those parts excluded in paragraph 5 below, the owner should do the following: (a) prepare a detailed written...

Open the catalog to page 10
DMX512 Interface LXU03 - 11

DECLARATION OF CONFORMITY according to IEC Guide 22 and EN 45014 Manufacturer's Name: ASTEL, Podjetje za projektiranje, proizvodnjo in trgovino, d.o.o. Manufacturer's Address: Dutovlje 138 6221 Dutovlje Slovenija declares that the products Item, Product Name and Model Number: 1. DMX512 Interface LXU03 conform to the following Product Specifications: EMC: EN 55022 (CISPR 22: 1993) EN 50130-4: 1994 Safety: EN 60950 EN 60529 Supplementary Information: The products herewith comply with the requirements of the following Directives and carry the CEmarking accordingly: - the EMC Directive...

Open the catalog to page 11

All ASTEL LIGHTING catalogs and technical brochures

  1. Meteor XP

    12 Pages

Archived catalogs

  1. LRMN Niche

    4 Pages

  2. LCPNXP Niche

    4 Pages

  3. LCFN Niche

    4 Pages