Group: ASTEL d.o.o.
Catalog excerpts
LXU01 DMX512 INTERFACE Operating Instructions LIGHTING
Open the catalog to page 1PREFACE PRECAUTIONS The LXU01 is DMX512 to ASTEL protocol converter with 1 output to control a groups of RGB multi-color lights of METEOR series with built-in ASTEL protocol. The DMX512 control of single-color lights METEOR series is enabled by using the PWM dimmer LDU13 with built-in ASTEL protocol. FEATURES 1 Control Output DIP-switch Programmable Multi - Speed Mode Wide Range Power Supply Low Power Consumption Polarity Protection Transient Protection Short Circuit Output Protection Simple Installation 3 The DMX512 Interface LXU01 has to be installed and used in accordance with the...
Open the catalog to page 3CONTROLS AND CONNECTORS DMX512 Interface LXU01 4 DMX SETTINGS ON 1 2 3 4 5 6 7 8 9 10 11 12 1 2 DC IN C DMX IN D D OUT 3 (1) DC IN Terminal-block connector to connect 12-24Vdc power supply. (2) OUT Control output to connect the +Control (P) and GND Control (-) wires of multi-color RGB lights Meteor series or PWM dimmer LDU13. (3) CONTROL The 3-pole terminal block connector to connect DMX512 line. (4) DMX SETTINGS DIP-switch to set the DMX512 and ASTEL protocol commmunication parameters. 4
Open the catalog to page 4INSTALLATION The DMX512 Interface LXU01 kit consists of the following components: DMX512 Interface LXU01 3 x terminal-block connectors Operating Instructions with Declaration of Conformity and Warranty conditions The LXU01 has to be installed on a suitable location. Avoid the installation in extremely hot places and near appliances generating strong magnetic fields. The installation has to be realized by a qualified personnel. Note: The main DC power supply has to be switched off before installation. D D+ GND DMX512 LINE F2A DMX SETTINGS ON 1 2 3 4 5 6 7 8 9 10 11 12 DC IN ASTEL PROTOCOL...
Open the catalog to page 5SET-UP The DMX512 Interface LXU01 set-up is enabled by adjusting the DIP-switch. ON 1 2 3 4 5 6 7 8 9 10 11 12 DIP-switch 1-2-3-4-5-6-7-8-9 DIP-switch 1-2-3-4 OFF-OFF-OFF-OFF ON –OFF-OFF-OFF OFF-ON –ON –ON ON –ON –ON –ON OFF-OFF-OFF-OFF-OFF-OFF-OFF-OFF-OFF ON -OFF-OFF-OFF-OFF-OFF-OFF-OFF-OFF ON –ON -OFF-OFF-ON -OFF-ON –ON -OFF OFF-ON –ON –ON –ON –ON –ON –ON -ON ON –ON –ON –ON –ON –ON –ON –ON -ON VALUE 0 1 14 15 VALUE 0 1 211 510 511 In normal operation the switches 1 - 9 define the DMX address! Note: The switch 12 must be in OFF position for normal operation! The DIP-switch is used to...
Open the catalog to page 6Speed mode Defines the ASTEL protocol communication baud rate. Value 0 1 2 FUNCTION LOW speed – 1200 bps MID speed – 2400 bps HIGH speed – 4800 bps Number of addressable lights This defines how the OUT is acting. There are two basic modes: -non addressable – all the lights on the control OUT light in the same way -addressable – there can be up to 15 address and each light connected to the OUT can have the address from 1 to 15 – each light with different address can light different. There can be more than one light with the same address – the number of the lights with the same address is not...
Open the catalog to page 7Programming the light address The set up procedure: 1. Connect the light to the DMX512 interface LXU01 2. Connect the light to the power supply 3. Switch-on the light – the light must light! 4. Switch-off the light – the light must NOT light! 5. Disconnect the light from power supply 6. Connect the DMX interface LXU03 to the power supply 7. Set the switch 12 to ON position 8. Set the programming mode – with the switches 5 – 8 to ON position 9. Set the light new address to 1-15 - with the switches 1 – 4 10. Connect the light to the power supply and IMMEDIATELY continue with step 11! 11. Set...
Open the catalog to page 8WARRANTY 1. The equipment manufactured by ASTEL d.o.o. is warranted to be free from defects in workmanship and materials under normal use and service. 2. This Warranty is in effect for of two years from the date of purchase by the user. Proof of purchase must be included, to establish that it is inside the warranty period. 3. This Warranty is transferrable and covers the product for the specified time period. 4. In case any part od the equipment proves to be defective, other than those parts excluded in paragraph 5 below, the owner should do the following: (a) prepare a detailed written...
Open the catalog to page 9DECLARATION OF CONFORMITY according to IEC Guide 22 and EN 45014 Manufacturer's Name: ASTEL, Podjetje za projektiranje, proizvodnjo in trgovino, d.o.o. Manufacturer's Address: Dutovlje 138 6221 Dutovlje Slovenija declares that the products Item, Product Name and Model Number: 1. DMX512 Interface LXU01 conform to the following Product Specifications: EMC: EN 55022 (CISPR 22: 1993) EN 50130-4: 1994 Safety: EN 60950 EN 60529 Supplementary Information: The products herewith comply with the requirements of the following Directives and carry the CEmarking accordingly: - the EMC Directive...
Open the catalog to page 10All ASTEL LIGHTING catalogs and technical brochures
-
Architectural Lighting 2024
43 Pages
-
Astel USA Brochure
2 Pages
-
Architectural Lighting 2023
56 Pages
-
Pool LED Lighting 2024
25 Pages
-
Meteor XP
12 Pages
-
METEOR_LSR36500manualENG_v2
12 Pages
-
METEOR_LSR36240manualENG_v2
12 Pages
-
METEOR_LSR1280manualENG_v2
12 Pages
-
METEOR_LSR0640manualENG_v2
12 Pages
Archived catalogs
-
ARCHITECTURAL LIGHTING 2020
60 Pages
-
SOMBRA_00XX manual
12 Pages
-
SOLEA_0XXX manual
12 Pages
-
LRMN Niche
4 Pages
-
METEOR_LSR0640manual
12 Pages
-
METEOR_LSR36240manual
12 Pages
-
METEOR_LSR1280manual
12 Pages
-
LCPNXP Niche
4 Pages
-
LCFN Niche
4 Pages
-
Architectural Lighting 2019
52 Pages
-
Architectural Lighting 2018
48 Pages
-
Underwater pool LED lights 2018
40 Pages
-
Surface Ground LED Light UFO
12 Pages
-
Inground LED Light VOLCANO
16 Pages
-
Wall LED Light SOMBRA
16 Pages
-
Flood - Path LED Light SIGMA
16 Pages
-
Flood LED Light SOLEA
16 Pages
-
Path LED Light SPARK
16 Pages
-
Architectural lighting 2017
48 Pages
-
Indoor LED Lighting 2016
8 Pages
-
Outdoor LED Lighting 2016
36 Pages
-
Indoor LED Lighting 2015
8 Pages
-
Linear Pool Niche LLPN
8 Pages
-
Concrete Pool Niche LCPN
4 Pages
-
Surface Mount Niche LSMN
4 Pages
-
PAR56 Adapter LPAR56
4 Pages
-
DMX512 Interface LXU03
12 Pages
-
PWM Dimmer LDU13
12 Pages
-
Synchonization Unit LSU08
12 Pages