1. Catalogs
  2. Asio
  3. as-shower

as-shower

as-shower

Product catalog summary
Introduction
The document discusses the AS-SHOWER heat exchanger, a device designed to recover heat from wastewater to save energy in domestic hot water production. It claims to save up to 45% of energy typically wasted.

Specifications
The exchanger is suitable for wastewater heat recovery with a maximum water pressure of 16 bars and a temperature of 90°C. It is designed to work with shower water temperatures ranging from 37°C to 40°C.

Functionality
The AS-SHOWER exchanger uses corrugated stainless steel plates to transfer heat from wastewater to fresh water. This preheats the cold water, reducing the need for hot water and thus saving energy.

Installation Recommendations
The exchanger should be installed under or near the shower pan on a horizontal surface. It requires connections for both wastewater and clean water, with specific recommendations for pipe types and connection methods.

Maintenance
Regular cleaning is necessary to maintain efficiency. Environmentally friendly cleaning solutions are recommended to remove deposits from the exchanger and drain pipes.

Technical Parameters
- Maximum water pressure: 16 bar
- Maximum water temperature: 90°C
- Exchanger casing: ABS plastic
- Absorber: Stainless steel (AISI 316 Class)
- Wastewater connection: DN40
- Clean water connection: G ¾”
- Dimensions: 552 x 144 x 87 mm

Contact Information
ASIO Ltd., Kšírova 552/45, 619 00 Brno, Czech Republic
Phone: +420 548 428 111
Email: [email protected]
Website: www.asio.cz
See more

Catalog excerpts

as-shower-1

A heat exchanger in your bathroom … an elegant solution saving up to 45% of energy spent for the domestic hot water production. The exchanger is intended for wastewater heat recovery up to the maximum water pressure of 16 bars and temperature 900C. For showering, hot water from 370C to 400C is normally used. Out of this hot water, we are able to use for showering about 50C, which accounts for 10% only. The remaining water (at the temperature of 350C) ends without any use in a sewer. This means that 90% of energy we use for heating of the water is wasted. The new shower exchanger AS-SHOWER can reduce such losses very efficiently. It can use 45% of energy for preheating of cold water and decrease thus the hot water consumption. The exchanger working part, i.e. the absorber, is formed of corrugated plates made of polished stainless steel sheets. Fresh water flows through a system of channels inside the plates and gets warm by taking the heat from the wastewater flowing over the absorber surface. As the fresh water temperature from the water mains is about 100C, it can draw some 12 to 140C from the wastewater warm at 350C. If the lukewarm water, preheated in the exchanger, is brought to the mixing valve, then the hot water stream is blended here with it (instead of the cold water coming directly from the mains) to provide warm water at the temperature usually used for showering. In this way, the hot water consumption drops down even by 45%, and this represents the savings offered by the AS-SHOWER exchanger. The necessary showering comfort is then provided with automatic water blending in a thermostatic mixing valve. Placements The exchanger installation should be considered before your bathroom retrofitting or fitting a new bathroom. According to space requirements and possibilities, it is advisable to place the exchanger under the shower pan or as close as possible to it. The exchanger must be always laid on a horizontal surface. It is necessary to have accessible both drain and cold water inlet. Connections Wastewater flows over the drain trap to the exchanger and then it continues to a sewer. A DN40 plastic pipe should be used for the wastewater connection. The exchanger is a counter-current type and the clean water inlet is always closer to the wastewater outflow. Flexible armoured hoses with cap nuts and flat gaskets can be suitably used for the clean water connection. For more details, see the Installation & Operating Instructions. Clean working surfaces of the exchanger are the basic precondition for the heat transfer. During regular cleaning of the shower pan siphon the deposits formed in the draining pipe and in exchanger should be removed. We advise to use environmentally friendly, biological based preparations, where bacteria consuming the impurities existing in the drain will do the cleaning work for you. All you have to do is to pour the cleaning solution into the shower pan siphon. Technical parameters Water pressure Water temperature Exchanger casing Absorber Wastewater connection Clean (cold) water connection Dimensions clean preheated water - outlet max. 16 bar max 90°C ABS plastic (vacuum forming) Stainless steel pressed sheet (AISI 316 Class) DN40 G ¾” 552 x 144 x 87 mm wastewater - inlet from the siphon clean cold water - inlet wastewater - outlet ASIO Ltd. Kšírova 552/45, 619 00 Brno, Czech Republic Phone: +420 548 428 111 E-mail: [email protected], www.asio.cz

 Open the catalog to page 1

All Asio catalogs and technical brochures

  1. as-plurafit

    2  Pages

  2. as-rewa

    4  Pages

  3. as-asli

    2  Pages

  4. as_rewa_

    4  Pages

  5. AS-FAKU

    6  Pages

Archived catalogs

  1. IFAT

    1  Page

  2. IFAT1

    1  Page

  3. IFAt 2

    1  Page

  4. IFAT 3

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.