Product catalog summary
Overview: The document introduces a new commercial tile product with Diamond 10 Technology coating, offering significant maintenance cost savings compared to traditional VCT (Vinyl Composition Tile). The product reduces or eliminates the need for initial floor polish application and the stripping and recoating process, maintaining a newer appearance with enhanced resistance to scratches, stains, and scuffs.
Key Benefits:
  • Up to 40% savings on maintenance costs.
  • 50% reduction in initial polish application.
  • 50% fewer coats needed to achieve maximum gloss.
Packaging & Installation Recommendations:
  • Tiles are packaged face down, with a glossier back coating for structural balance.
  • Maintain installation area temperature between 65°F (18°C) and 100°F (38°C).
  • Acclimate product, adhesives, and subfloor for 48 hours before installation.
  • Conduct moisture, alkali, and bond tests on subfloor.
  • Ensure subfloor is free of contaminants for optimal adhesion.
Installation Tips:
  • Use sharp blades and replace trowels as needed due to product durability.
  • Ensure adhesive is dry-to-touch before setting tiles.
  • Roll installed tiles with a 100 lb. roller for better adhesion.
Post-Installation & Maintenance:
  • Use protective panels for heavy loads within 72 hours post-installation.
  • Initial maintenance includes sweeping and using a neutral detergent solution.
  • Long-term maintenance involves machine scrubbing and applying fewer coats of polish in high-traffic areas.
  • Proper furniture rests are crucial for maintaining floor appearance.
See more

Catalog excerpts

INSTALLATION TIPS FOR COMMERCIAL TILE WITH DIAMOND 10® TECHNOLOGY COATING-1

INSTALLATION TIPS FOR COMMERCIAL TILE WITH DIAMOND 10® TECHNOLOGY COATINGCommercial Tile Reinvented Save up to 40% on average compared to traditional VCT polished maintenance procedures - by reducing or eliminating the initial application of floor polish and reducing or eliminating the stripping and recoating process. With Diamond 10 Technology coating, floors look newer, longer with improved resistance to scratches, stains and scuffs vs. traditional VCT. S-515 Tile Strong™ S-525 BBT Bio-flooring Adhesive ✓ Eliminate or reduce initial application of polish by 50% ✓ Eliminate or reduce restorative stripping and recoating ✓ Maximize gloss level with 50% fewer coats of polish vs. traditional VCT Packaging & Recommended Adhesives Tiles may feature a back coating to ensure a balanced product structure, directly out of the box. The back of each tile will have a glossier appearance compared to traditional VCT as a result. Before installation, flip tiles. The tiles are packaged face down except for the last tile in the carton. Follow these steps to ensure a successful installation. Visit armstrongflooring.com for complete installation instructions. Before Installation ✓ HVAC The area to receive the resilient flooring should be maintained at a minimum of 65° F (18° C) and a maximum of 100° F (38° C). Installation conditions that are outside our recommendations or uncontrolled will result in a noticeable curl or dome. ✓ Acclimation ✓ Subfloor Testing ✓ Bond Test ✓ Subfloor Preparation Resilient flooring should only be installed in temperature-controlled environments. It is necessary to maintain a constant temperature before, during and after the installation. The product, adhesives, and subfloor must acclimate for 48 hours. Before installation of the finished flooring, moisture and alkali testing must be conducted. The surface of the concrete must have a pH of 9 or less. Bond tests must also be conducted for compatibility with the substrate. Skipping this step may result in subpar adhesion of the product to the subfloor. The surface should be free of dust, solvents, varnish, paint, wax, oil, grease, sealers, curing compounds, residual adhesive, adhesive removers, and other foreign materials. The high gloss surface of the product will make subfloor imperfections more noticeable.

 Open the catalog to page 1
INSTALLATION TIPS FOR COMMERCIAL TILE WITH DIAMOND 10® TECHNOLOGY COATING-2

INSTALLATION TIPS FOR COMMERCIAL TILE WITH DIAMOND 10® TECHNOLOGY COATING During Installation ✓ Cutting The superior durability of this product may result in the perception that this product is more difficult to cut. Armstrong Flooring’s expert installation team has reviewed the product and recommends standard installation tools. One suggestion is to make sure you use sharp blades and replace trowels as necessary. Do NOT set this product in wet adhesive. The adhesive must be dry-to-touch to reduce the possibility of the product moving during installation. Smaller tiles (usually on the perimeter)...

 Open the catalog to page 2

Archived catalogs

  1. BruceHardwood

    60  Pages

  2. A Book 2014

    50  Pages

  3. Wood Brochure

    17  Pages

  4. Bruce Laminate

    50  Pages

  5. Vinyl Sheet

    92  Pages

  6. MEDINPURE™

    8  Pages

  7. PRYZM

    8  Pages

  8. NexPro™ X

    2  Pages

  9. NexPro™

    2  Pages

  10. NexPro™ XL

    2  Pages

  11. Alterna

    48  Pages

  12. Vinyl Sheet

    56  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.