Catalog excerpts
Safety Data Sheet Product Identifier: Mineral Fiber Acoustical Ceiling Tiles and Wall Panels (Class A) #1 * * *Section 1 - IDENTIFICATION* * * Material Name: Mineral Fiber Acoustical Ceiling Tiles and Wall Panels (Class A) #1 Chemical Family Man-made vitreous fiber ceiling tile Recommended Use acoustical ceiling tiles Restrictions on Use None known. Manufacturer Information Armstrong World Industries 2500 Columbia Ave. Lancaster, PA 17603 Phone #: 877-276-7876 Email: techline@armstrong.com Emergency #: 1-800-255-3924 (ChemTel) www.armstrong.com * * *Section 2 - HAZARD(S) IDENTIFICATION* * * Classification in accordance with 29 CFR 1910.1200. Not classified as hazardous GHS LABEL ELEMENTS Symbol(s) None Signal Word None Hazard Statement(s) None Precautionary Statement(s) During the installation be certain that the work site is well ventilated and avoid breathing dust. Avoid contact with skin or eyes. Wear long-sleeve, loose fitting clothes, gloves and eye protection. Cut and trim with knife, razor or hand saw. Do not cut with power equipment unless either a dust collector is used on the equipment or local exhaust is used and a NIOSH approved respirator is worn to prevent ovrexposure to airborne silica. Exposures to respirable crystalline silica are not detected in industrial hygiene testing on workers installing acoustical ceiling panels for an 8 hour work day and are not expected during the normal use of this product; however, actual levels must be determined by workplace hygiene testing. Prolonged and repeated exposure to airborne free respirable crystalline silica can result in lung disease (i.e., silicosis) and/or lung cancer. Panels do not release respirable dust in their installed state and therefore do not present any known health hazards when installed and properly maintained. Prevention Do not breathe dust, mist, fumes or vapors. Do not handle until all safety precautions have been read and understood. Wash thoroughly after handling. Wear protective gloves/clothing and eye/face protection. Obtain special instructions before use. Use only outdoors or in a well-ventilated area.
Open the catalog to page 1@fmstrong CEILINGS Safety Data Sheet Product Identifier: Mineral Fiber Acoustical Ceiling Tiles and Wall Panels SDS ID: ARM-003 (Class A) #1 Response IF exposed or concerned: Get medical advice/attention. IF INHALED: Remove person to fresh air and keep comfortable for breathing. IF ON SKIN: Wash with plenty of soap and water. If skin irritation occurs: Get medical advice/attention. Take off contaminated clothing and wash before re-use. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation...
Open the catalog to page 2Safety Data Sheet Product Identifier: Mineral Fiber Acoustical Ceiling Tiles and Wall Panels (Class A) #1 * * *Section 5 - FIRE-FIGHTING MEASURES* * * Suitable Extinguishing Media carbon dioxide, regular dry chemical, regular foam, water spray Unsuitable Extinguishing Media None known. Special Hazards Arising from the chemical Combustible dust. Avoid generating dust; fine dust dispersed in air in sufficient concentrations, and in the presence of an ignition source is a potential dust explosion hazard. Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low...
Open the catalog to page 3@)rn strong CEILINGS Safety Data Sheet Product Identifier: Mineral Fiber Acoustical Ceiling Tiles and Wall Panels SDS ID: ARM-003 (Class A) #1 Conditions for Safe Storage, including any Incompatibilities Store in a cool, dry place. Store in a well-ventilated place. Avoid contact with molten material. Keep separated from incompatible substances. Keep container tightly closed. Empty containers may contain product residue. Do not reuse empty containers without commercial cleaning or reconditioning. Store and handle in accordance with all current regulations and standards. Incompatibilities:...
Open the catalog to page 4@rmstrong CEILINGS Safety Data Sheet Product Identifier: Mineral Fiber Acoustical Ceiling Tiles and Wall Panels SDS ID: ARM-003 (Class A) #1 Ensure that dust-handling systems (such as exhaust ducts, dust collectors, vessels, and processing equipment) are designed in a manner to prevent the escape of dust into the work area (i.e., there is no leakage from the equipment). Use only appropriately classified electrical equipment and powered industrial trucks. Individual Protection Measures, such as Personal Protective Equipment Eyes/Face Protection Wear splash resistant safety goggles with a...
Open the catalog to page 5@mstrong® CEILINGS Safety Data Sheet Product Identifier: Mineral Fiber Acoustical Ceiling Tiles and Wall Panels SDS ID: ARM-003 (Class A) #1 Hazardous Decomposition Combustion: Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. **~*Section 11 - TOXICOLOGICAL INFORMATION* * * Acute Toxicity No information available for the product. See component data. Component Analysis - LD50/LC50 The components of this material have been reviewed in various sources and the following selected endpoints are published: Quartz(inbound)...
Open the catalog to page 6Safety Data Sheet Product Identifier: Mineral Fiber Acoustical Ceiling Tiles and Wall Panels (Class A) #1 A Human Carcinogen (biopersistent, related to Glass wool fiber) OSHA: Present (related to Glass wool fiber) ACGIH: A4 - Not Classifiable as a Human Carcinogen Aluminium hydrous silicate: Kaolin clay (1332-58-7) ACGIH: A4 - Not Classifiable as a Human Carcinogen DFG: Category 3B (could be carcinogenic for man) ACGIH: A2 - Suspected Human Carcinogen IARC: Monograph 100C [2012]; Monograph 68 [1997] (Group 1 (carcinogenic to humans)) NTP: Known Human Carcinogen...
Open the catalog to page 7@rnstrong CEILINGS Safety Data Sheet Product Identifier: Mineral Fiber Acoustical Ceiling Tiles and Wall Panels SDS ID: ARM-003 Disposal Methods Dispose in accordance with all applicable regulations. Regulations vary. Consult local authorities before disposal. Component Waste Numbers The U.S. EPA has not published waste numbers for this product's components. Disposal of Contaminated Packaging Dispose of waste material according to Local, State, Federal, and Provincial Environmental Regulations. * * *Section 14 - TRANSPORT INFORMATION* * * US DOT Information Not regulated as a hazardous...
Open the catalog to page 8All Armstrong ceilings - USA catalogs and technical brochures
-
CEILING & WALL LOOK BOOK 2023
16 Pages
-
Ceiling & Wall Guide
24 Pages
-
Ultima+ brighten your space
6 Pages
-
PRELUDE 24 - TL2
4 Pages
-
Laminated Ceiling Solutions
15 Pages
-
ABOOK 2018
47 Pages
-
THE WINNING CHOICE
8 Pages
-
LUXURY FLOORING
40 Pages
-
VINYL plank flooring
24 Pages
-
LUXE PLANK®
28 Pages
-
ALTERNA™ & ALTERNA RESERVE
56 Pages
-
Inspiring Great Spaces
8 Pages
-
WoodHaven Ceiling Planks
3 Pages
-
METALLAIRE™
6 Pages
-
Custom creation
6 Pages
-
Room dividers
18 Pages
-
Retail Ceiling Guide
28 Pages
Archived catalogs
-
CEILING & WALL LOOK BOOK
16 Pages
-
Metallaire Styles
6 Pages
-
Custom Creations Brochure
2 Pages
-
Contractor Series
8 Pages
-
HomeStyle® Ceilings
8 Pages
-
Tin Look™ Paintable Ceilings
6 Pages
-
WoodHaven™ Ceiling Planks
8 Pages
-
basement inspiration
8 Pages
-
DECORAT I V E C E I L I N G
8 Pages
-
Definitions Room Dividers
18 Pages
-
Metallaire Ceilings
6 Pages
-
Decorative Ceilings
6 Pages
-
WoodHaven Ceilings
6 Pages
-
Tin Look
4 Pages
-
Retail Ceiling Guide
8 Pages