Introduction
The document is a technical manual for TERAJOINT® and TERAJOINT® Strong, robust joint systems for concrete floors. These prefabricated systems include load transfer mechanisms and are made from recyclable materials, available in various finishes for different environments.
Product Properties
TERAJOINT® systems create shrinkage-free movement joints with heavy-duty armoring and load transfer capabilities, suitable for high flatness and superflat floor construction. They accommodate minor slab movements and transfer vertical loads between slabs.
Materials and Dimensions
Materials include cold drawn steel profiles and high-strength steel dowels, available in plain steel, galvanized, stainless, and acid-proof stainless steel. Dimensions vary by system type and version.
Resistances
Resistances are determined according to UK Concrete Society TR34.4, with tables detailing design resistances for various dowel types and slab thicknesses to meet load transfer and shear capacity requirements.
Selection Criteria
Selection is based on slab depth, joint opening, environmental conditions, and joint aspect ratio, with recommendations for different scenarios like internal floors and corrosive environments.
Installation and Design
Guidelines for installation and a design form assist in selecting the appropriate system based on slab thickness, joint opening, and environmental conditions. Material options and safety factors for concrete and steel are outlined.
Conclusion
TERAJOINT® systems provide versatile solutions for durable concrete floors, with comprehensive information on properties, materials, resistances, and selection criteria for optimal performance.
Load Specifications
Permanent loads have a safety factor of 1.35, imposed loads 1.50, point loads 1.50, and dynamic loads 1.60. Dynamic magnification factors are 1.4 for pneumatic tires and 2.0 for solid tires, with forklift specifications detailed for classes FL 1 to FL 6.
Installing TERAJOINT®
Installation involves protecting joints from weather, ensuring vertical installation, and following steps for sub-base preparation, joint location, sequential installation, and concrete pouring.
Revisions
The document includes a revision history detailing changes in materials, dowel types, and updates to resistances and design forms.
Design Tools and Support
Peikko offers design software, 3D components, installation instructions, and technical support, with approvals and certificates available online.
See more

Catalog excerpts

TJ6-230-3000-1

TERAJOINT® and TERAJOINT® Strong Free Movement Joints Robust Free Movement Joint Systems Version

 Open the catalog to page 1
TJ6-230-3000-2

TERAJOINT® and TERAJOINT® Strong Free Movement Joints Robust Free Movement Joint Systems • Prefabricated leave-in-place free movement joint system with a variety of integral load transfer mechanisms to suit all floor loadings. • Excellent performance with 40mm x 10mm cold drawn steel for extreme armoring of joint arrises. • TERAJOINT® is specially designed for moderate and medium loads • TERAJOINT® Strong is specially developed to meet heavy duty requirements • Suitable for the high flatness category floor and superflat floor construction. • Fast track installation with a selection of fixing methods...

 Open the catalog to page 2
TJ6-230-3000-4

About TERAJOINT® Free Movement Joint 1. Product Properties TERAJOINT® is a prefabricated leave-in-place joint system designed to create (construct) formed shrinkage free movement joints, consisting of heavy duty arris armoring, permanent formwork, and a load transfer system. The arris armoring is provided by 40 × 10 mm cold drawn steel profiles, which are connected by yieldable plastic bolts. The profiles are anchored into the slab by means of a number of 10 × 100 mm welded anchors, and one of the profiles is welded onto the steel divider plate, which has the load transfer system positioned and...

 Open the catalog to page 4
TJ6-230-3000-5

TERAJOINT® Dowel Types. Dowel Type Sleeve Color Adjustable Joint Opening Dowel Type Sleeve Color Adjustable Joint Opening Dowel Type Sleeve Color Adjustable Joint Opening Dowel Type Sleeve Color Adjustable Joint Opening Version: PEIKKO GROUP 06/2020

 Open the catalog to page 5
TJ6-230-3000-6

Table 2. Materials and standards of TERAJOINT® TJ5, TJ6, TJS6, TJS8. TERAJOINT® AND TERAJOINT® STRONG FREE MOVEMENT JOINTS

 Open the catalog to page 6
TJ6-230-3000-7

VERSION: PEIKKO GROUP 06/2020

 Open the catalog to page 7
TJ6-230-3000-8

Table 8. Dimensions [mm] of TERAJOINT® R-Section. Type NOTE: TERAJOINT® R-Sections are not standard products to be stored. They will be manufactured according to order. TERAJOINT® AND TERAJOINT® STRONG FREE MOVEMENT JOINTS

 Open the catalog to page 8
TJ6-230-3000-9

Information TERAJOINT® with foam Peikko can deliver TERAJOINT® with closed cell polyethylene foam to the places where slabs are cast in the cool condition and thermal expansion is significant. The thickness of the foam (tf) can be 5 / 10 / 15 mm. tf Peikko Group’s production units are externally controlled and periodically audited on the basis of production certifications and product approvals by various independent organizations. Version: PEIKKO GROUP 06/2020

 Open the catalog to page 9
TJ6-230-3000-10

Resistances of the TERAJOINT® dowels are determined according to UK Concrete Society TR34.4 published August 2013. Table 9. Load transfer and required verifications for single plate dowels. P Load transfer Punching shear at the face of the loaded area Punching shear on the critical perimeter Bearing/bending capacity of dowel Shear capacity of dowel TERAJOINT® and TERAJOINT® Strong Free Movement Joints

 Open the catalog to page 10
TJ6-230-3000-11

Table 10. Design resistance of single dowel in shear P, and bearing/bending P , [kN] according TR34.4 for Design resistance [kN/m] covers all required verifications listed in Table 9. The punching shear resistances are calculated for plain concrete without any kind of additional reinforcement and according to TR34.4 the same approach should also be used for steel and macro-synthetic fiber reinforced concrete. If resistances for other joint openings or concrete grades, or slabs thicker than 250 mm are needed, please contact Peikko Technical Support. VERSION: PEIKKO GROUP 06/2020

 Open the catalog to page 11
TJ6-230-3000-12

Selecting TERAJOINT® Free Movement Joint TERAJOINT® is selected according to following criteria: • • • Slab depth. It is recommended that the joint depth, TERAJOINT® height, is at least 10 mm shallower than the slab depth. Advisable slab depths are stated in Tables 4 and 5. Designed joint opening. For joint openings of up to 15 mm wide, we recommend TERAJOINT® TJ5 or TERAJOINT® TJ6. For joint openings from 20 to 30 mm wide, TERAJOINT® TJS8 is recommended. Whereas for pile supported slabs, we would only recommend the use of TERAJOINT® TJS8. Environment. For internal floors, we would suggest the...

 Open the catalog to page 12
TJ6-230-3000-13

Appendix A - TERAJOINT® Design formBasic dimensions Thickness of the slab h = Pre-opening of joint: Thickness of foam f = Type of Peikko flooring product = Maximum length of slab A = Difference of temperatures of slab At = (recommended value 0 ~ 20 mm, maximum allowed value 30 mm) (default value 0 mm, available 5/10/15 mm) TERAJOINT® for joint opening < 15 mm or TERAJOINT® Strong for joint opening < 30 mm (maximum length of slab perpendicular to TERAJOINT® connection) - maximum At or A2 recommended value = 1.50 Standard, HDG, Stainless or Acid proof recommended value = 1.15 (based on soil type)...

 Open the catalog to page 13
TJ6-230-3000-14

Loads Permanent loads Characteristic permanent load gk = kN/m2 Partial safety factor for permanent load yg = Characteristic imposed load qk = kN/m2 Partial safety factor for imposed load yq = Characteristic value of point load Qp = kN Partial safety factor for point load yQp = Partial safety factor for dynamic load yQk = Dynamic magnification factor q> = Characteristic axle load of forklift Qk = Width of contact area = Distance between middle of contact areas a = value 1.4 for pneumatic tires and value 2.0 for solid tires based on type of forklift (FL 1~6) recommended value 200 mm based on type...

 Open the catalog to page 14
TJ6-230-3000-15

Installing TERAJOINT® Free Movement Joint General The handling of TERAJOINT Free Movement Joins must be done by following safety instructions. The free movement joints on site must be protected from weather, damage during handling and possible damage during removal on the packing. Joints should be stored in dry and sheltered conditions. Before use, the free movement joints are inspected visually for completeness and any signs of damage that might have occurred during transport or storage. The assessment of the products is based on the assumption that during the estimated working life no maintenance...

 Open the catalog to page 15

All Archflex (ARDEX DESIGN) catalogs and technical brochures

  1. D 1600

    2  Pages

  2. D 1500

    3  Pages

  3. D 1400

    2  Pages

  4. D 1350

    2  Pages

  5. D 1000

    2  Pages

  6. CW

    4  Pages

  7. CC

    4  Pages

  8. D 1100

    3  Pages

  9. WTZ

    3  Pages

  10. FB

    2  Pages

  11. ST 1000

    2  Pages

  12. R 2001

    3  Pages

  13. TJ6-245-3000

    20  Pages

  14. TJ6-215-3000

    20  Pages

  15. TJ6-185-3000

    20  Pages

  16. TJ5-160-3000

    20  Pages

  17. TJ5-135-3000

    20  Pages

  18. TJ5-115-3000

    20  Pages

  19. TJ5-90-3000

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About ArchiExpo
ArchiExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. ArchiExpo is an entity of VirtualExpo Group.