Maukatherm T iQ+ - 1

Maukatherm T iQ+ PIR sandwich panel Standard colors Hairexcel® 60 Metallic color Finishing Flashings Short lengths EXTRA Maukatherm T iQ+ is aesthetic and presents the advantage of a warm roof that is easy to install. Its installation requires 2.5 times less time than that of a conventional zinc standing seam roof. Please note: as for zinc roofing, Maukatherm T iQ+ presents an unavoidable phenomenon of oil canning (warped appearance, scattered warping). Panel characteristics Panel nominal thickess (mm) 70 Thickness of the outer / inner facing (mm) Overall length (mm) End cuts (mm) Aspect of the outer facing Standing seam Aspect of the inner facing Weight (kg/m²) Reaction to fire Thermal transmittance Uc (W/m².k) Linear heat loss y (W/m.K) Surface loss coefficient Up (W/m2.K) Thermal resistance R (m².K/W) • 1 repartition plate and 1 screw on end support • 1 repartition plate and 2 screws on intermediate support Roof sandwich panels ArcelorMittal Construct

Open the catalog to page 1
Maukatherm T iQ+ - 2

Maukatherm T iQ+ PIR sandwich panel Application table for nominal panel thickness of 70 mm Admissible spans in meters for facings tickness 0.60 / 0.50 mm. Please note: For suction, the maximum load to be retained, fixings included, corresponds to the lowest value in the row. Wind loads on panels and fixings are defined in our Climatic and seismic actions guide. Panel alone Nominal thickness 70 mm Multiple span Single span Loads (daN/m2) 2 supports Pressure Suction Pressure Suction Pressure Suction Pressure Suction Pressure Suction Pressure Suction Pressure Suction Pressure Suction Pressure...

Open the catalog to page 2
Maukatherm T iQ+ - 3

Maukatherm T iQ+ PIR sandwich panel Application table for nominal panel thickness of 100 mm Admissible spans in meters for facings tickness 0.60 / 0.50 mm. Please note: For suction, the maximum load to be retained, fixings included, corresponds to the lowest value in the row. Wind loads on panels and fixings are defined in our Climatic and seismic actions guide. Panel alone - Nominal thickness 100 mm Multiple span Single span Loads (daN/m2) Wind resistance of fixings Roof sandwich panels ArcelorMittal Construction France 5 supports and more Pk/gm: 248 minimal Pressure Suction Pressure...

Open the catalog to page 3