neon AMR Masonry Reinforcement Fabricated steel reinforcement, located in the bed joint to strengthen masonry panels without thickening the wall The longitudinal steel wires are flattened to ensure good mortar cover is maintained, even when lapped or used with wall ties Materials Stainless steel, galvanised steel Wire Diameters 3.0, 3.5, 4.0, 4.5, 5.0mm (equivalent diameter after flattening) Depth Flattened to less than 3mm Minimise wall thickness. ~ ~ Maximise structural performance. v v www.ancon.co.uk BUILDING PRODUCTS
Open the catalog to page 1Ancon AMR Masonry Reinforcement Ancon AMR is used to improve the structural performance of masonry walls, in accordance with BS5628-2: 2005, by providing additional resistance to lateral loads e.g. wind. It can also be used to reduce the risk of cracking either at stress concentrations around openings or as a result of movement, in accordance with BS5628-3: 2005. Available in various standard configurations, the Ancon AMR suits a wide range of structural load conditions and wall widths. The longitudinal wires have a minimum characteristic yield strength of 500N/mm2. Materials Ancon AMR is available...
Open the catalog to page 2Design Sheet - Masonry Panel Design to BS EN 1996 (UK National Annex) Please ensure all fields marked with an asterix * are completed. 1. CONTACT DETAILS * Contact name. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . * Single Leaf or Cavity Wall * Project name and town. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Note: The information that you provide below will be applied to both the inner and outer leaves unless otherwise specified. EXAMPLE SKETCH select from the following materials: Clay brick Calcium silicate brick Aggregate concrete...
Open the catalog to page 3Design Sheet - Masonry Panel Design to BS EN 1996 (UK National Annex) Only for use as a continuation page to an Ancon design sheet and where all loads and wall construction details are unchanged COMPANY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PROJECT NAME & TOWN . . . . . . . . . . . . . . . . . . . . . . . . . . . . Add all support conditions and dimensions PANEL REF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Add all support conditions and dimensions Faxback to +44 (0) 114 276 8543 or email: [email protected]...
Open the catalog to page 4Ancon AMR eXtra Masonry reinforcement with cross wires which offer something extra Industry concerns over the build quality of reinforced masonry panels have led Ancon to develop the innovative AMR-X. This new product features shaped cross wires which ensure the longitudinal wires are located in the centre of a bed joint. AMR-X: • Accelerates construction times • Improves build quality • Reduces site supervision requirements Masonry Reinforcement with the ‘X’ factor AMR-X has been designed to be installed either way up and is available in two wire diameters and two widths.
Open the catalog to page 5Ancon AMR-X When compared to other ladder-type reinforcement, Ancon AMR-X can accelerate the speed of construction, improve build quality and reduce the requirement for site supervision. Ladder-type reinforcement is located in bed joints to provide additional resistance to lateral loads and improves the structural performance of a masonry wall. It is important that the steel is surrounded by mortar to ensure the designed performance is achieved on site. A number of construction managers have expressed their concerns to Ancon that standard masonry reinforcement can easily be installed incorrectly....
Open the catalog to page 6Product Datasheet Ancon AMR-CJ for Collar Jointed Walls Ancon AMR-CJ masonry reinforcement allows the construction of collar-jointed walls i.e. two leaves of thin masonry used in place of a single leaf of wider, heavier blockwork. Ancon AMR-CJ is used to tie the two leaves together, so it acts as a single unit. The product consists of 20 x 2.5mm flat ties welded to flattened longitudinal wires at 450mm centres. The longitudinal wires have a minimum characteristic yield strength of 500N/mm². Product Width AMR-CJ is supplied in a standard width of 175mm to suit wall widths of 215mm comprising two...
Open the catalog to page 716 Pages
12 Pages
10 Pages
1 Page
12 Pages
28 Pages
16 Pages
4 Pages
2 Pages
2 Pages
6 Pages
8 Pages
2 Pages
12 Pages
12 Pages
8 Pages
24 Pages
12 Pages
20 Pages
16 Pages
16 Pages
2 Pages
12 Pages
12 Pages
32 Pages
8 Pages
20 Pages