Catalog excerpts
Continuity Systems BUILDING PRODUCTS
Open the catalog to page 1Other Rebar Continuity Systems Ancon manufactures other reinforcement continuity systems for use when bar diameters exceed 16mm, lap lengths do not fit within an Eazistrip box and onsite bar straightening is keen to be avoided. KSN Anchor System Here, Ancon KSN threaded anchors are supplied fixed to a galvanised steel casing and used in conjunction with Bartec parallel threaded reinforcing bars. Standard anchors are available to accept bars of 12mm, 16mm and 20mm diameter in a lap length to suit the application. Starter Bar System This system consists of a Starter Bar which is supplied...
Open the catalog to page 2Ancon designs and manufactures high integrity steel products for the construction industry. Through continuous programmes of new product development, inward investment and employee advancement, the company is committed to maintaining the highest level of customer service within a dynamic and challenging industry. Masonry Support Systems Masonry Reinforcement Windposts and Parapet Posts Wall Ties and Restraint Fixings Channel and Bolt Fixings Tension and Compression Systems Insulated Balcony Connectors Shear Load Connectors Punching Shear Reinforcement Continuity Systems Stainless Steel...
Open the catalog to page 3Eazistrip Reinforcement Continuity Systems EAZISTRIP REINFORCEMENT CONTINUITY SYSTEMS The Eazistrip Reinforcement Continuity System is a quick and easy to install method of maintaining continuity of reinforcement at construction joints in concrete. It consists of a galvanised steel casing with a dimpled surface to provide an effective concrete bond. Pre-bent bars are housed within the casing and are enclosed by a protective cover. Each end of the unit is sealed with a polystyrene block in order to prevent the ingress of concrete. The complete unit is nailed to the formwork. Alternatively it...
Open the catalog to page 4STANDARD RANGE CONFIGURATIONS Type 80 When the stirrup width exceeds 220mm, units will be supplied as two single overlapping hooks, to be positioned side by side. *Other centres are available Notes: Units containing 16mm bars are nominally 50mm deep. On 16mm Ø Type U boxes, the stirrup may be achieved using two shape code 21 bars. These are referenced DH.
Open the catalog to page 5Eazistrip Reinforcement Continuity Systems STANDARD RANGE SPECIFICATIONS U TYPE BOX DIMENSIONS The following tables give details of the Eazistrip purpose made units to suit their particular application. In order to meet this requirement I Ancon will manufacture according to your f == h \ specific bar arrangement. The most common [ I_\ shapes are shown on page 10. For further details please contact Ancon Building Products. ~ Part No. Box Width Box Rebar Dia Centres Stirrup Stirrup Leg mm Length mm mm mm Height (h) mm Width (b) mm Length (I) mm Bars / Box Notes: Those sizes shown in bold are...
Open the catalog to page 6Continental Range Dimensions Part No. Box Width Box Rebar Dia Centres Stirrup Stirrup Leg mm Length mm mm mm Height (h) mm Width (b) mm Length (I) mm Bars / Box Notes: Dimensions shown in the above table are nominal. Heights and lengths may typically vary by one bar diameter. Maximum box length is 3m dependant upon weight. Boxes with a DH reference contain double hook bars rather than a single U bar. Units containing 16mm bars are nominally 50mm deep (d).
Open the catalog to page 7Eazistrip Reinforcement Continuity Systems INSTALLATION 1 Nail the Eazistrip through the casing to the formwork or alternatively securely tie the projecting anchorage reinforcing bars back to the main reinforcement. In both cases the Eazistrip box should be securely fixed to avoid displacement during concreting. The casing should be tight against the formwork. Pour concrete. 2 Strike the formwork to reveal the cover. 3 BAR STRAIGHTENING The bars in the Eazistrip box must be straightened using the appropriate sized Ancon Eazistrip re-bending tool. This is a steel tube designed to fit over...
Open the catalog to page 8Identify the location of the intended cut. 2 Slide the protective cover from the box and remove the bars which pass over the cut location. 3 Cut through the steel casing using a disc cutter. 4 Replace the bars to face the opposite direction to their original position. Cut the cover to the same lengths as the steel casing and replace to protect the bars. The ends of the boxes must be sealed, using polystyrene blocks, to prevent the ingress of concrete. Note: Protective gloves should be worn when removing covers, straightening bars, cutting boxes and during general handling of Eazistrip.
Open the catalog to page 9Eazistrip Reinforcement Continuity Systems ENQUIRY/ORDER FORM Please photocopy this page and use it to detail your enquiry/order. Ancon can be contacted by fax on +44 (0) 114 238 1240 or by email on concrete@ancon.co.uk h Type H Hook (standard in 80mm box) Type SH Angle with leg in horizontal plane Type U U Bar/ DH Double Hook (not available in 80mm box) Type S2 Double Straight Bar Type 2H Two Single Hooks used for boxes wider than 240mm b Type RA2 Double Angle Type RA1 Double Angle Item Type RA3 Double Angle Stirrup Type Type CS Closed Stirrup Stirrup Height h (mm) Re-bending Tool (1)...
Open the catalog to page 10EAZISTRIP WATER STOP OTHER ANCON PRODUCTS Where the potential for water ingress through the construction joint is a major concern, Eazistrip can be supplied with a Pentaflex hydrostatic seal. The seal is factory fitted inside and outside the box to provide double-sided protection against water or moisture permeation along the joint face. Reinforcing Bar Couplers The use of reinforcing bar couplers can provide significant advantages over lapped joints. Design and construction of the concrete can be simplified and the amount of reinforcement required can be reduced. The Ancon range includes...
Open the catalog to page 11Ancon Building Products President Way, President Park Sheffield S4 7UR United Kingdom Tel: +44 (0) 114 275 5224 Fax: +44 (0) 114 276 8543 Email: info@ancon.co.uk Visit: www.ancon.co.uk Follow: @AnconUK Ancon (Middle East) FZE PO Box 17225 Jebel Ali Dubai United Arab Emirates Tel: +971 (0) 4 883 4346 Fax: +971 (0) 4 883 4347 Email: info@ancon.ae Visit: www.ancon.ae Ancon Building Products 114 Kurrajong Avenue Mount Druitt Sydney NSW 2770 Australia Tel: +61 (0) 2 8808 1111 Fax: +61 (0) 2 9675 3390 Email: info@ancon.com.au Visit: www.ancon.com.au Ancon (Schweiz) AG Gewerbezone Widalmi 10 3216...
Open the catalog to page 12All Ancon Building Products catalogs and technical brochures
-
Eazistrip
16 Pages
-
Tapered Thread Couplers
12 Pages
-
MBT MechanicallyBolted Couplers
10 Pages
-
Staifix HRT4 Wall Tie
1 Pages
-
2019 Staifix Wire Balloons
1 Pages
-
Stainless steel wall ties
1 Pages
-
EC2-Compliant Design Method
12 Pages
-
Reinforcing Bar Couplers
28 Pages
-
Tension and Compression Systems
16 Pages
-
Restraint System
4 Pages
-
Ancon Thermal Breaks
2 Pages
-
Gauge Tape
2 Pages
-
Non-Drill Wall Ties
6 Pages
-
Refractory Fixings
8 Pages
-
Staifix Wall Ties
2 Pages
-
Special Fabrications
12 Pages
-
Punching Shear Reinforcement
12 Pages
-
Starter Bar Systems
8 Pages
-
KSN Anchors
24 Pages
-
Lockable Dowels
12 Pages
-
DSD/ESD Shear Load Connectors
20 Pages
-
Masonry Reinforcement
16 Pages
-
Tension and Compression Systems
16 Pages
-
Corner Guards
2 Pages
-
Hidden Strength
7 Pages
-
Stainless Steel in Construction
12 Pages
-
12 Page Product Guide
12 Pages
-
Wall Ties and Restraint Fixings
32 Pages
Archived catalogs
-
2016 Staifix Wire Balloons
1 Pages
-
Channel and Bolt Fixings
20 Pages
-
Windposts and Parapet Posts
8 Pages