Catalog excerpts
Thermal Windpost (TWP2) Thermal Efficiency: the new revolution in windposts
Open the catalog to page 1The Ancon Thermal Windpost (TWP2) The patented Ancon Thermal Windpost (TWP2) is designed to span vertically between floors, to provide additional lateral support for panels of masonry. It has been engineered after extensive research and testing, with a variety of features to improve the thermal performance and repeatability of the junction. Why is the Thermal Windpost revolutionary? The first of its kind, and beneficial for both contractors and designers alike, the Thermal Windpost has been designed unlike any other windpost seen on the market. Thanks to its robust integral non-combustible...
Open the catalog to page 2Minimising thermal transmission The use of thinner gauge stainless steel reduces the amount of highly conductive material penetrating the insulation layer. The additional inclusion of a thermal slot array within the insulation zone slows the rate of thermal flux locally and in turn further reduces transmission through that part of the web. This is particularly efficient when fully surrounded by insulation. Ancon Thermal Windpost (TWP2) Standard angle section windpost Ensuring repeatability Gaps between the cavity insulation panels and the post have a detrimental effect on the thermal...
Open the catalog to page 3Ancon Thermal Windpost (TWP2) The importance of thermal specification An increasing focus on thermal bridging and energy efficiency means that components now have to go above and beyond in order to achieve the often tight thermal specification requirements. Windposts are structural members which inevitably create a discontinuity in the insulation layer; Angle sections almost fully penetrate the inner leaf of the wall and part of the insulation, and channel sections can sometimes bridge the insulation layer. The small voids that are created within and around the post as a result of this can...
Open the catalog to page 4Comparison between TWP2 and WP2 in sensitivity to gaps and variations in installation of insulation adjacent to the post (Assumes 75mm partial fill insulation and insulation installed behind the flange) Traditional WP2 sections in 75mm thick partial fill insulation Thermal Windpost TWP2-165-A/B/C/D in 75mm thick partial fill insulation The Thermal Windpost (TWP2) is much less sensitive to variations, maintaining performance better than the default value of 0.18W/mK irrespective of minor variations. Design and Installation Thermal Windposts are installed into the inner leaf of blockwork in a...
Open the catalog to page 5Ancon Thermal Windpost (TWP2) Load Capacity Tables (for posts built in to a solid mortar joint) Ancon Windposts are designed as ‘simply supported beams’ with a maximum deflection of span/360. The tables below include examples of the Ancon Thermal Windposts maximum design loads to BS EN 1993 (Eurocode 3) when built in to a mortar joint. The design resistances shown should be compared to factored loads. Ancon Windposts comply with all UKCA & CE marking requirements of BS EN 1090-1, including designs to EN 1993 (Eurocode 3) and external certification of our factory production controls by an...
Open the catalog to page 6Design Charts for the Built in Case The charts below provide loading information for four popular partial fill insulation thicknesses to aid specification. Leviat can provide custom charts for a given depth on request, please contact our Technical Services Team for more information. Limited by wall ties Post Depth = 165mm (Typically 75mm partial fill insulation) Post Depth = 190mm (Typically 100mm partial fill insulation) Total Design Resistance (kN ULS, uniformly distributed) 26.00 Total Design Resistance (kN ULS, uniformly distributed) Limited by wall ties Post Depth = 215mm (Typically...
Open the catalog to page 7For more information on these products, contact: Leviat President Way President Park Sheffield, S4 7UR United Kingdom Tel: +44 (0) 114 275 5224 Fax: +44 (0) 114 276 8543 Email: info.ancon.uk@leviat.com For sales enquiries: Email: sales.ancon.uk@leviat.com For technical enquiries: Email: tech.ancon.uk@leviat.com Ancon.co.uk Leviat.com Imagine. Model. Make. Leviat.com Leviat.com
Open the catalog to page 8All Ancon Building Products catalogs and technical brochures
-
Eazistrip
16 Pages
-
Tapered Thread Couplers
12 Pages
-
MBT MechanicallyBolted Couplers
10 Pages
-
Staifix HRT4 Wall Tie
1 Pages
-
2019 Staifix Wire Balloons
1 Pages
-
Stainless steel wall ties
1 Pages
-
EC2-Compliant Design Method
12 Pages
-
Reinforcing Bar Couplers
28 Pages
-
Tension and Compression Systems
16 Pages
-
Restraint System
4 Pages
-
Ancon Thermal Breaks
2 Pages
-
Gauge Tape
2 Pages
-
Non-Drill Wall Ties
6 Pages
-
Refractory Fixings
8 Pages
-
Staifix Wall Ties
2 Pages
-
Special Fabrications
12 Pages
-
Punching Shear Reinforcement
12 Pages
-
Starter Bar Systems
8 Pages
-
KSN Anchors
24 Pages
-
Lockable Dowels
12 Pages
-
DSD/ESD Shear Load Connectors
20 Pages
-
Masonry Reinforcement
16 Pages
-
Tension and Compression Systems
16 Pages
-
Corner Guards
2 Pages
-
Hidden Strength
7 Pages
-
Stainless Steel in Construction
12 Pages
-
12 Page Product Guide
12 Pages
-
Wall Ties and Restraint Fixings
32 Pages
Archived catalogs
-
2016 Staifix Wire Balloons
1 Pages
-
Channel and Bolt Fixings
20 Pages
-
Windposts and Parapet Posts
8 Pages