Introduction
The AMVIC ECOAIR™ Ground-Air Heat Exchange System is designed to provide efficient ventilation for homes and buildings. Proper maintenance is crucial to ensure its longevity and effectiveness, as well as to maintain the validity of the limited warranty provided by AMVIC Construction LLC.
Maintenance Recommendations
  • Annual inspection and cleaning by a qualified professional are recommended.
  • Change the air filter in the air inlet tower once or twice a year, depending on environmental conditions.
  • Avoid modifications to the system and refrain from using chemicals to clean the interior of the heat transfer pipes.
  • Exercise caution when digging near the system's pipes.
  • Follow all manufacturer recommendations for the building's ventilation system.
Air Quality and Safety
  • AMVIC does not guarantee air quality, which is influenced by ambient air conditions.
  • The system must be designed and maintained to minimize contaminants and microbial growth.
  • The silver-enabled inner surface of the pipes helps inhibit microbial growth but is not a substitute for proper system design and maintenance.
Filter Maintenance
  • The air inlet filter is a MERV 8 rated polyester fiber mesh. It should be inspected every six months and replaced at least once a year for systems with airflow rates less than 588 cfm.
  • Replacement filters can be purchased through the system installer or AMVIC dealers.
Professional Maintenance
  • Annual inspection and cleaning by a certified professional, such as a NADCA practitioner, are recommended.
  • For commercial buildings, follow ANSI/ASHRAE/ACCA Standard 180-2008 for HVAC system maintenance.
Warranty Information
  • The AMVIC ECOAIR PVC Pipe is warranted to be free of defects for ten years, and associated hardware for two years.
  • Warranty is void if the system is improperly handled, installed, or maintained.
  • Claims must be made within 30 days of a defect occurrence, and AMVIC must be allowed to inspect the system.
  • AMVIC's liability is limited to repair, replacement, or refund of the defective product.
See more

Catalog excerpts

Amvic EcoAIR Warranty-1

Unlimited Polymer Solutions AMVIC ECOAIR™ GROUND-AIR HEAT EXCHANGE SYSTEM MAINTENANCE GUIDE AND LIMITED WARRANTY

 Open the catalog to page 1
Amvic EcoAIR Warranty-2

Dear Homeowner/Building Owner: A AMVIC ECOAIR ground-air heat exchange system has been installed in your home or building. In order to ensure proper operation for the lifetime of the system and to ensure that the AMVIC limited warranty remains in effect, the following recommendations must be followed: − Arrange for annual inspection and, if necessary, cleaning of the AMVIC ECOAIR system by a qualified professional. − Change the air filter in the air inlet tower once or twice a year depending on air flow volume and environmental conditions. − Do not modify or alter the ground-air heat exchange...

 Open the catalog to page 2
Amvic EcoAIR Warranty-3

AMVIC makes no guarantees regarding the quality of air supplied by the AMVIC ECOAIR ground-air heat exchange system. The air quality is predominantly influenced by the ambient air. − It is the responsibility of the project owner and his/her designates to ensure proper ventilation is supplied to the building. − Ground-air heat exchange systems must be properly designed, installed and maintained to minimize entry of particulates, allergens and odors and to reduce the risk of microbial growth. − The unique silver-enabled inner surface of AMVIC ECOAIR pipe enhances the system’s ability to inhibit...

 Open the catalog to page 3
Amvic EcoAIR Warranty-4

maintenance owner responsibilities Proper maintenance of your AMVIC ECOAIR system will keep it operating efficiently for many years. Failure to change filters as necessary may reduce system efficiency and supply of fresh air. This air inlet filter is a polyester fiber mesh material that is rated as a MERV 8. Minimum Efficiency Reporting Value (MERV) is a measure of filter effectiveness as defined in ASHRAE Standard 52-2, table 12-1. MERV rating relates to the arrestance rating of the filter at three particle sizes ranging from 0.3-10 microns at a certain face velocity. Changing the Air Inlet...

 Open the catalog to page 4
Amvic EcoAIR Warranty-5

Purchasing Replacement Filters AMVIC provides high-efficiency replacement filters rated to European BS EN 779:2002 standard. The comparable ASHRAE standard is shown below. Filter Rating European BS EN 779:2002 Standard Comparable ASHRAE 52.1 Standard There are two approaches to filtration. One option is a filter set including one F6-rated fine filter that extends several feet down inside the tower and one G2-rated coarse filter that is positioned inside the tower cover. The other option is a single G4-rated medium filter that is positioned inside the tower cover. To purchase a new filter or filter...

 Open the catalog to page 5
Amvic EcoAIR Warranty-6

Arranging for Annual Professional Maintenance For best performance, owners should arrange for a qualified professional such as a certified practitioner of the National Air Duct Cleaners Association (NADCA) to inspect and, if necessary, to clean their AMVIC ECOAIR system at least once a year. For residential buildings, the National Air Duct Cleaners Association (NADCA) provides duct cleaning recommendations in ACR 2006 Assessment, Cleaning and Restoration of HVAC Systems. For commercial buildings, the relevant standard is ANSI/ASHRAE/ACCA Standard 180-2008, Standard Practice for Inspection and...

 Open the catalog to page 6
Amvic EcoAIR Warranty-7

AMVIC ECOAIR LIMITED WARRANTY Subject specifically to the terms of this Limited Warranty, AMVIC Construction LLC or AMVIC Industries Inc., as applicable, (“AMVIC”) warrants solely and specifically to: (a) the purchaser of Products (as defined below) from AMVIC, (b) the owner of the applicable real property at the time of the installation, and (c) the first transferee thereafter, provided the transfer of applicable real property occurs no later than five (5) years after the beginning of the warranty period, that: (i) AMVIC ECOAIR PVC Pipe (the “Pipe”) shall be free of defects in material and workmanship...

 Open the catalog to page 7
Amvic EcoAIR Warranty-8

For updates to this publication, visit amvicsystem.com/ecoair The information contained herein is believed to be reliable, but no representations, guarantees or warranties of any kind are made as to its accuracy, suitability for particular applications or the results to be obtained therefrom. © 2011 AMVIC www.amvicsystem.com [email protected]

 Open the catalog to page 8

All Amvicsystem catalogs and technical brochures

  1. Amvic ICF R30

    2  Pages

  2. Amvic ICF R22

    2  Pages

  3. AmDry Tile

    2  Pages

  4. THERMOQUIET®

    2  Pages

  5. Silverboard

    2  Pages

  6. ICF

    2  Pages

  7. Amvic ICF

    2  Pages

  8. EIFS

    2  Pages

  9. AmDrain

    2  Pages

  10. AmDock

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.