

Catalog excerpts

U85 Agglomerated cork with recycled polyurethane foam and recycled rubber layer for impact noise insulation of floating screed P R O D U C T S P E C I F I C AT I O N "___mm resilient acoustic underscreed made of agglomerated cork, recycled polyurethane foam and recycled rubber with PU elastomer bonding agent for impact noise insulation of floating screeds, with a density between 280 and 400 kg/m³ and an impact noise reduction DLw of ___dB.” ▸▸ Impact noise reduction and thermal insulation properties ▸▸ Very easy to handle and long term resilience ▸▸ Produced from recycled and natural materials ▸▸ Very light and flexible material Thickness (mm) Width (m) x Length (m) Others sizes available upon request THERMAL PROPERTIES Thermal Conductivity (W/mK) PHYSICAL AND MECHANICAL PROPERTIES Specific Weight (Kg/m³) ➀ Tensile Strength (KPa) ➁ Recovery after 0.7MPa (%) ➂ ➀ ASTMF1315 ➁ ASTMF152 ➂ A
Open the catalog to page 1
Test procedure according to ISO 10140-1:2010; ISO 10140-3:2010; ISO 10140-4:2010 and ISO 717-2:2013 standards. ❶ Concrete floating screed with 70mm thickness ❷ Agglomerated cork, PU and rubber resilient layer with one face dimpled - U85 Normalized impact pressure level L [dB] ❸ Reinforced concrete slab of thickness 140mm 70 DYNAMIC STIFFNESS Dynamic Stiffness (MN/m³) ➀ 30 Normalized impact sound pressure level of the reference floor with the floor covering under test Ln,r,0 Normalized impact sound pressure level of the Lab reference floor ΔLw Impact sound pressure level reduction index of...
Open the catalog to page 2
G E N E R A L I N S TA L L AT I O N I N S T R U C T I O N S The following installation instructions are recommended by Amorim Cork Composites, but are not intended as a definitive project specification. They are presented in an attempt to be used with recommended installation procedures of the flooring manufacturers and screed. Room Conditions Temperature > -5ºC / Room moisture content < 75%. Subfloor All subfloor work should be structurally sound, clear and level. The moisture content of the subfloor should not be more than 2.5% (CM) by weight measured on concrete subfloors. Perimeter Insulation...
Open the catalog to page 3All Amorim Cork Composites catalogs and technical brochures
-
ACM30
1 Pages
-
YOGA COLLECTION
8 Pages
-
Let’s cork together
36 Pages
-
T92 selection
4 Pages
-
T04 maximum
5 Pages
-
T85 comfort
4 Pages
-
T27 force
4 Pages
-
T47 versatile
4 Pages
-
T51 protection
3 Pages
-
T56 endurance
4 Pages
-
T61 balance
5 Pages
-
T66 performance
4 Pages
-
UNDERL AYS
8 Pages
-
General brochure Acousticork EN
22 Pages