U36 Agglomerated natural cork blended with high density PU foam and EVA for impact noise and thermal insulation P R O D U C T S P E C I F I C AT I O N “___mm resilient acoustic underscreed made of agglomerated cork and polyurethane foams (PU) with EVA for impact noise insulation of floating screeds, with a density between 370 and 500kg/m³ and an impact noise reduction ΔLw of___ dB.” ➀ as per ISO 10140-3 and ISO 717-2 ➁ ASTM E2179-03; ASTM E492-09; ASTM E989-18; ASTM E2235-04 ▸▸ Impact noise reduction and thermal insulation properties ▸▸ Long-term resilience ▸▸ Produced from recycled and natural materials ▸▸ Light and flexible material, easy to handle Width (m) x Length (m) Others sizes available upon request F I R E C L A S S I F I C AT I O N THERMAL PROPERTIES E/Efl ➀ Thermal Conductivity (W/mK) PHYSICAL AND MECHANICAL PROPERTIES Specific Weight (Kg/m³) ➀ Tensile Strength (KPa) ➁ Cp level (mm) ➂ ➀ ASTMF1315 ➁ ASTMF152 ➂ ISO 092/19 ➃ For both thicknesses 6/3 and 8/4 ➀ ➁ ➂ as per ISO 7322
Open the catalog to page 1PHYSICAL AND MECHANICAL PROPERTIES Normalized impact pressure level L [dB] Note: Following ISO8013-1998 measured in Cantilever Test System Normalized impact sound pressure level of the reference floor with the floor covering under test Ln,r,0 Normalized impact sound pressure level of the Lab reference floor T E S T A P PA R AT U S ( Δ L W ) ❶ Concrete floating screed with 70mm thickness ❷ Agglomerated resilient layer - U36 ❸ Reinforced concrete slab of thickness 140mm DYNAMIC STIFFNESS Thickness (mm) Dynamic Stiffness (MN/m³) ➀ ➀ as per ISO 9052-1:1989; ISO 7626-5:1994
Open the catalog to page 2G E N E R A L I N S TA L L AT I O N I N S T R U C T I O N S The following installation instructions are recommended by Amorim Cork Composites, but are not intended as a definitive project specification. They are presented in an attempt to be used with recommended installation procedures of the flooring manufacturers and screed. Room Conditions Temperature > -5ºC / Roommoisture content < 75%. Subfloor All subfloor work should be structurally sound, clear and level. The moisture content of the subfloor should not be more than 2.5% (CM) by weight measured on concrete subfloors. Perimeter...
Open the catalog to page 3All Amorim Cork Composites catalogs and technical brochures
-
ACM30
1 Pages
-
YOGA COLLECTION
8 Pages
-
Let’s cork together
36 Pages
-
T92 selection
4 Pages
-
T04 maximum
5 Pages
-
T85 comfort
4 Pages
-
T27 force
4 Pages
-
T47 versatile
4 Pages
-
T51 protection
3 Pages
-
T56 endurance
4 Pages
-
T61 balance
5 Pages
-
T66 performance
4 Pages
-
UNDERL AYS
8 Pages
-
General brochure Acousticork EN
22 Pages