video corpo

Secura Lath ®
1 /12Pages

Secura Lath ®

Secura Lath ®
1 /12Pages

Catalog excerpts

Secura Lath ®-1

Secura Lath ALABAMA METAL INDUSTRIES CORPORATION GIBRAL ALT INDUSTRIE CORPOR TRIES ORPORA GIBRALTAR INDUSTRIES CORPORATION Physical Security Penetration Barrier for Plaster and Stucco Applications

 Open the catalog to page 1
Secura Lath ®-2

SECURA LATH® SECURA LATH INSTALLATION GUIDELINES PRODUCT DEVELOPMENT Secura Lath was born out of necessity. After the development of AMICO Security Mesh, specifiers requested that we develop a product that would provide a superior penetation barrier for plaster and stucco applications. After years of lab and field testing, Secura Lath was ready for market and was introduced in 1994 at the Construction Specifications Institute trade show. Since then hundreds of thousands of square feet of Secura Lath have been installed to the satisfaction of owners, designers, specifiers, and contractors. PRODUCT...

 Open the catalog to page 2
Secura Lath ®-3

SECURA LATH® SUSPENDED CEILING FRAMING INSTALLATION The Supporting Framework AMICO Secura Lath serves as a structural base for the stucco or plaster, and the framing structure is the foundation for the lath. Because Secura Lath is somewhat stouter , the framing system has been strengthened and should be installed as follows: 1. Use 8GA 0.1620-inch (4.12mm) galvanized hanger wire for suspension of hangers. 2. Mechanically anchor hanger wires to the ceiling or sub-floor system, by use of drilled and inserted anchors or pre installed loops embedded in the concrete. See ASTM C1063 for other acceptable...

 Open the catalog to page 3
Secura Lath ®-4

SECURA LATH® Lath Preparation Secura Lath may be cut with abrasive metal cutting blades in a circular saw, with a power shear , and for small areas with hand held channel nippers or bolt cutters which have been ground to fit the diamond shaped openings. When cutting ASL with power tools one should wear goggles, mask and ear protection, so as to avoid injury. Suspended Ceiling SECURA LATH INSTALLATION ASTM C1063 requires that metal lath be lapped a minimum of ½ inch (12.7mm) on the sides and 1-inch (25.4mm) on the ends. ASL should be installed with the long way of the diamond (long way of the...

 Open the catalog to page 4
Secura Lath ®-5

SECURA LATH® Note: It is imperative that all openings are cased with X-66 casing bead attached to the Secura Lath to completely isolate the plaster membrane from all protrusions and dissimilar material. Ceiling Perimeter Expansion Many designers are concerned by the 3/8-inch (9.5mm) space which remains between the edge of the casing bead and the wall with ceiling applications.This could easily be a hiding place for contraband. HoweverAMICO recommends , the use of a light 30Ga or less wall angle, 1½” x 1” (38.1mm x 25.4mm) to close this gap. Refer to the details on pages 8 and 12. Due to the flexibility...

 Open the catalog to page 5
Secura Lath ®-6

SECURA LATH® the stucco membrane at a rapid rate, causing the stucco to become weak and brittle. Allow sufficient time between coats to permit each coat to cure or develop enough rigidity to resist cracking or other physical damage when the next coat is applied. Contact EIFS finish manufacturers for information on recommended curing times for the brown coat of stucco, before the application of the acrylic finish. Additives It is our recommendation that AR (Alkali resistant) fibers be used in the scratch coat to give extra strength to the stucco. We also recommend that an acrylic modifier product...

 Open the catalog to page 6
Secura Lath ®-7

SECURA LATH® SECTION 09 57 53 PHYSICAL SECURITY PENETRATION BARRIER FOR PLASTER AND STUCCO APPLICATIONS 1.1 DESCRIPTION OF WORK Included work is not limited to the supply and installation of a complete in place security lath structural base for portland cement stucco or high strength gypsum plaster plus all complimentary accessories. 2.1 MANUFACTURER Physical penetration barrier shall conform to ASL .50-16R as manufactured by Alabama Metal Industries Corporation (AMICO), Birmingham, Alabama. Security Products Department: Telephone 800/366-2642. Facsimile 205/786-6527 www.amico-securityproducts.com...

 Open the catalog to page 7
Secura Lath ®-8

SECURA LATH CEILING PERIMETER EXPANSION CONTROL Uplift Control Mechanism Alabama Metal Industries Corporation

 Open the catalog to page 8
Secura Lath ®-9

CEILING EXPANSION JOINT DETAILS CLINCH SPLICE TIES ONLY _ SNUG ENOUGH TO ALLOW WIRE TIED TO THE FLANGES OF THE CONTROL JOINT WITH 16GA GALVANIZED WIRE. MAIN RUNNER CHANNEL CONTROL JOINT FURRING CHANNEL RUNNER CHANNEL CONTROL JOINT IS WIRE-TIED USING 16 GA GALVANIZED WIRE. CLINCH SPLICE TIES ONLY SNUG ENOUGH TO ALLOW FOR TELESCOPING, WHILE NOT RESTRICTING EXPANSION. FURRING CHANNEL PERIMETER RELIEF MINIMUM 1" CLEARANCE FOR MAIN RUNNERS FROM WALLS AND ALL PROTRUSIONS. CONTROL JOINT. SECURA LATH IS CUT AND WIRE TIED JOINT WITH 16 GA GALVANIZED OR DOUBLE LOOPED 18 GA WIRE. CONTROL JOINT CONTROL JOINT...

 Open the catalog to page 9
Secura Lath ®-10

SECURA LATH CEILING DETAILS CHANNEL MAIN RUNNER %' COLD ROLLED AMICO SECURA LATH- TYPICAL LAP JOINT WIRE-TIED Cut Casing Bead base flange only (do not cut 1/4" reveal flange) and bend cas- ing to 90° and carry terminal end at least 6 inches beyond the corner . Flatten bulged reveal at corner with light ham- mer taps to straighten and flush up with straight length to reveal. Wire-tie casing bead on top of casing security mesh. Place Secura Lath on top of casing the bead wing and wire-tie casing bead in conventional manner. If light fixtures, security grills, sprinkler pipes, or other penetrating...

 Open the catalog to page 10
Secura Lath ®-11

LIGHT & HVAC FIXTURES ISOLATED IN STUCCO CEILING PREFERRED METHOD Main Runner Light Fixture Furring Channel Flexible Caulk Required space Casing Bead Notes: 1) Casing Bead To Completely Isolate The Ceiling From All Vertical protrusions. 2) Light Fixture Or Diffuser Should Not Have Built In Casing Bead. Alabama Metal Industries Corporation

 Open the catalog to page 11
Secura Lath ®-12

Perimeter Ceiling Expansion Using AMICO X-66 Casing Bead and Galvanized Steel Angle SOFT GALVANIZED STEEL CASING BEAD The AMICO X-66 Casing Bead and Angle are designed for use as a perimeter closure for use with the AMICO Secura Lath ceiling system. X-66 Casing Bead is available with grounds up to 1%". VA" x 1" galvanized Angle must be 30GA or lighter to provide adequate flexibility and the cavity should remain unfilled. Traditionally a minimum of 3/8" to V£ gap must be left between the ceiling and the intersecting walls on all suspended ceiling applications. This gap is generally not acceptable...

 Open the catalog to page 12

All AMICO - Alabama Metal Industries catalogs and technical brochures

  1. Security Mesh

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.