
Monobloc 400º/2H exhaust hood EXCLUSIVE SHIELD DESIGN TO PREVENT FUME BACKFLOWFUMÉE BUILT-IN 400º/2H FAN WHERE AN EXTRACTOR HOOD CANNOT BE INSTALLED REMOTELY UV Possibility of installing UV filtration Possibility of installing automatic flow regulation Possibility of installing integrated luminaires Installing fire extinguishing system available MONOBLOC 400º/2H extractor hood, with all visible parts made of AISI.304 stainless steel with a fine, polished finish (approved by the EEC for food handling). The hood's shape has been especially studied to make the ensemble as rigid as possible, with metal sheet folds strategically placed to avoid any flat horizontal surface that would lead to condensation and grease drippings. It has a built-in attachment system to facilitate assembly. All of the extractor hood's visible parts were assembled with bolts welded on the inside, thus making it possible to disassemble the ensemble if necessary (so it fits through a small door, or to expand it) and a great finish with no visible rivets or screws. Top safety with a U-shaped reinforcement gutter around the perimeter, with folded rounded sheet metal to prevent cuts. It has a series of galvanised mesh filters measuring 390x490x50. It has a fan with a built-in motor 400ºC/2H, with Applus certification
Open the catalog to page 1Monobloc 400º/2H exhaust hood FAN 400ºC/200 H Enclosure in galvanized steel sheet. Turbine with forward blades, in galvanized steel sheet. External connection box. Homologation according to EN 12101-3: 2002, with certification Nº370-CPD-0580 and CPF Applus Finish: Anticorrosive in galvanized steel sheet MOTOR H-Class motors, continuous use S1 and emergency S2 use, with ball bearings. Three-phase 230/400v 50 Hz (up to 3/4 hp) and 400/690V 50 Hz (Powers higher than 3/4 hp) and Single-Phase 230v 50 Hz Maximum air temperature to be transported: Service S1-20ºc + 60º C continuous, Service S2 400º...
Open the catalog to page 2DRAINAGE SYSTEM Drainage system to collect grease held by the filter collector, with threaded metallic plug outlet. Gutter around the perimeter to collect condensation from inside the shield or protector and sides. MONOBLOC 400º / 2H LONGITUDES / LONGUEURS / LENGTHS FONDO/ PROFONDEUR/ DEPTH PARED / MURALE / WALL 1000 1200 1500 1700 2000 2200 2500 En un solo tramo En une seule pièce In a single piece Medidas superiores, múltiplos de estas Mesures supérieures, multiples de ces CENTRAL / CENTRALE / ISLAND 1200 1500 1700 2000 2200 En un solo tramo En une seule pièce In a single piece Medidas superiores,...
Open the catalog to page 3LONGITUDES / LONGUEURS / LENGTHS PROFONDEUR / DEPTH PARED / MURALE / WALL 1000 En un solo tramo En une seule pièce Monobloc / Monobloc 400º In a single piece 1200 Pared / Adossês / Wall Medidas superiores, múltiplos de éstas Mesures supérieures, multiples de ces Multiple of these for different lengths CENTRAL / CENTRALE / ISLAND 2200 En un solo tramo En une seule pièce In a single piece Medidas superiores, múltiplos de éstas Mesures supérieures, multiples de ces Multiple of these for different lengths PERFORMANCE CURVES Curvas de rendimiento email: [email protected]
Open the catalog to page 43 Pages
3 Pages
3 Pages
6 Pages
9 Pages
9 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages