video corpo

FIREFLEX FLYER
2Pages

{{requestButtons}}

Catalog excerpts

FIREFLEX FLYER - 1

F ANOR OR EXUS E COBU IST W NSILD INGITH TR IN B IN UCG U UIL 6M TI ND DIN O ON E G F R THE MARKET LEADING FIRE RATED TEMPORARY MODULAR BUILDING SOLUTION Fireflex® is an evolution of our extremely popular Moduflex open plan temporary building solution with the added benefit of having a fire rated performance to protect your people on site. The Elliott Fireflex modular building system has been specifically designed to provide enhanced fire protection to help operators meet the requirement of The Joint Code of Practice on the Protection from Fire of Construction Sites and Buildings Undergoing Renovations publication entitled “Fire Prevention on Construction Sites”, 9th Edition. The structure of Fireflex forms a fire rated enclosure to the module which exceeds the requirements of the Joint Code of Practice (JCOP) with each element of the building providing a minimum performance of 60 minutes and provides a high level of fire protection to both the occupants of the modular structure and adjacent buildings and properties. Fireflex has been independently assessed by Exova Warringtonfire. It is for use as single, two or three-storey buildings in applications exempt from the requirements of local Building Regulations and Standards. It is perfect for use as an open plan complex on a construction site. 360° Service Range We have a wide range of 360° Service Solutions for use with your Fireflex building including: • Fire extinguishers including water, CO2, powder and foam. • Fire accessories include stands, trolleys and fire blankets. • Fire & smoke alarms. • Fire safety training and fire risk assessments. For more information Freephone 0844 264 0874 or visit : www.e

Open the catalog to page 1
FIREFLEX FLYER - 2

Behaviour in relation to fire Fireflex is capable of exceeding the minimum requirements of the Fire Prevention on Construction Sites Joint Code of Practice, 9th Edition providing a minimum performance of 60 minutes from inside to out. Strength and stability Fireflex has adequate strength and stability and has been assessed in accordance with Eurocode UK National Annexes in one, two and three storey configurations. Thermal insulation Roofs, walls, floors are insulated to exceed the minimum requirements stated in BS6767-1:1999, Transportable Accommodation Units. Weather tightness and...

Open the catalog to page 2

All Algeco catalogs and technical brochures

  1. ANTI VANDAL+

    1 Pages

  2. Infrastructure

    20 Pages

  3. Retail

    20 Pages

  4. CONSTRUCTION

    20 Pages

  5. Education

    20 Pages

  6. RENTAL-SYSTEMS

    12 Pages

  7. iBex

    1 Pages

  8. Progress

    1 Pages

  9. RENTAL-SYSTEMS

    12 Pages

Archived catalogs