LINED
16Pages

{{requestButtons}}

Catalog excerpts

LINED - 1

Diffusers with adjustable aluminium slots LINED Linear series Assemblies LINED TP series LINED Slim series Connection plenum ^b LINED Combined series ^B Fixings ^B Range H Graphs H Selection

Open the catalog to page 1
LINED - 3

LINED Linear series - aluminium USE • Air supply or exhaust depending on model. • Adjustable diffusion using dirigible deflector in the centre of each slot. Vertical airflow possible. • Opening exhaust models with filter to replace that of ducted convector fan. • Ceiling-mounted. • Possibility of aesthetic linear strips (except opening versions). CONSTRUCTION • Body and deflectors made of extruded aluminium. • Frame 25 mm wide. Slot 25 mm wide. • LINED S: air supply model with dirigible deflectors. • LINED E: exhaust model with fixed deflectors. • LINED EO: exhaust model with fixed...

Open the catalog to page 3
LINED - 4

LINEAR STRIPS • Possibility of creating linear strips (alignment profiles supplied) or continuous arrangements with aesthetic corner pieces (non-diffusing). • Beyond 2000 mm, the diffuser is made up of 2000 middle sections with two ends of equal length always between 1000 and 2000 mm. For an order for a full linear strip: • L = Lm + 2 x Lgd. • Overall = Lm + 2 x Lgd + a. For an order for separate components: • Overall middle section = Lm. • Overall left or right section = Lgd + a/2. Note: LINED profile: a=20. Lm > 2000 mm. 1000 > Lgd > 2000. Size Whole section Middle section without end...

Open the catalog to page 4
LINED - 5

USE • Air supply or exhaust depending on model. • Adjustable diffusion using dirigible deflector in the centre of each slot. Vertical airflow possible. • Opening exhaust models with filter to replace that of ducted convector fan. • Diffusers planned to replace a standard suspended ceiling tile, Tbar or Fine-line. CONSTRUCTION • Body and deflectors made of extruded aluminium. • Ceiling compensation plate, galvanised steel. • Slot width 25 mm. • LINED S TP: air supply model with dirigible deflectors. • LINED E TP: exhaust model with fixed deflectors. • LINED EO TP: exhaust model with fixed...

Open the catalog to page 5
LINED - 6

USE • Air supply or exhaust. • Adjustable diffusion using dirigible deflector in the centre of each slot. Vertical airflow possible, • Opening exhaust models with filter to replace that of ducted convector fan, • Ceiling-mounted, • Possibility of aesthetic linear strips (except opening versions), • Diffuser designed without frame for perfect integration in metal ceilings. CONSTRUCTION • Body and deflectors made of extruded aluminium, • Slot width 25 mm, • LINED Slim: air supply model with dirigible deflectors, • LINED E Slim: exhaust model with fixed deflectors, • LINED EO Slim: exhaust...

Open the catalog to page 6
LINED - 7

USE • Plenums for slot diffusers LINED, LINED TP AND LINED SLIM series. • Air supply or exhaust. • Ceiling-mounted. • Possibility of linear strips. CONSTRUCTION • Made of galvanised steel sheet. • At base supply branch connection 300 to 1500 mm long and two supply branch connections 1505 to 2000 mm long. • Possibility of adding connections upon request. ATTACHMENTS • S2: concealed attachment of the diffuser to the plenum using a screw accessible by the sides of the diffuser. Caution: this attachment is not compatible with plaster or BA13 plasterboard ceilings. • S3: concealed attachment of...

Open the catalog to page 7
LINED - 8

LINED Combined series - aluminium USE • Combined air supply and exhaust for all ventilation and air conditioning applications • Adjustable diffusion using dirigible deflector in the centre of each slot. Vertical airflow possible, • Possibility of adding a filter on the exhaust section to replace, for example, that of the connected ducted convector fan, • Ceiling-mounted, • Diffuser designed for simultaneous air supply and exhaust thanks to its specific plenum (see next page). CONSTRUCTION • Body and deflectors made of extruded aluminium, • Slot width: 25 mm • LINED SO: LINED linear air...

Open the catalog to page 8
LINED - 9

USE • Plenums for slot diffusers LINED Combined series, • Combined air supply and exhaust, • Ceiling-mounted. CONSTRUCTION • Plenum specific to the LINED Combined performing air supply and exhaust simultaneously. • The plenum is divided into two for the air supply and exhaust, • The exhaust section is fitted with a filter that can be accessed from the front panel of the diffuser, • Made of galvanised steel sheet. • An air supply branch connection and an exhaust branch connection of same diameter. ATTACHMENTS • S2: concealed attachment of the diffuser to the plenum using a screw accessible...

Open the catalog to page 9
LINED - 10

Diffusers with adjustable aluminium slots LINED - LINED TP - LINED Slim - LINED Combined series attachments and filter replacement LINED diffuser • ttachment by self-tapping screws on the sides of the A plenum. NB: this attachment method is recommended for suspended ceilings and incompatible with non-removable ceilings (plaster or BA13 plasterboard). S3 ATTACHMENT • oncealed attachment to plenum adjustable and C accessible via the underside of the diffuser. NB: this attachment allows simple and rapid installation, with the possibility of adjusting the position of the diffuser to pin it...

Open the catalog to page 10
LINED - 11

RANGE WITH CHOICE OF OPTIONS Not available in models with filter.

Open the catalog to page 11
LINED - 12

CORRECTIONS FOR OTHER VT CORRECTIONS FOR DAMPER CORRECTIONS FOR VERTICAL AIR SUPPLY A T°(°K)

Open the catalog to page 12
LINED - 13

CORRECTIONS FOR OTHER LENGTHS HEAD LOSSES WITH FILTER G3 INCLUDED

Open the catalog to page 13
LINED - 14

The values Lw (dB (A)) do not take into account any attenuation by the building itself. AP2=with filter G3 included. Tests conducted with the standard plenum.

Open the catalog to page 14
LINED - 15

SELECTION - AIR SUPPLY + EXHAUST FOR LENGTH 1 M WITH CEILING EFFECT Ak (m2) Data valid for a diffuser with centred partition (air supply length = exhaust length). Please consult us for other configurations. The values Lw (dB (A)) do not take into account any attenuation by the building itself. Tests conducted with the standard plenum. AP1 = air supply only AP2 = exhaust only AP3 = exhaust with filter SPECIFICATION TEXT • The ceiling diffusers will be linear with slots 25 mm wide and with adjustable deflectors allowing horizontal or vertical diffusion or air exhaust. • They may be opening...

Open the catalog to page 15

All ALDES catalogs and technical brochures

  1. TWISTED

    5 Pages

  2. MR MAX

    6 Pages

  3. Bahia Curve

    8 Pages

  4. ColorLINE®

    1 Pages

  5. PLAFONE

    4 Pages

  6. VELONE

    15 Pages

  7. Bap Color

    4 Pages

  8. OPTIFLEX

    40 Pages

  9. In Line

    20 Pages

  10. Nano Air 50

    8 Pages

  11. InspirAir

    20 Pages

  12. EasyHOME®

    60 Pages

  13. COMPULSOR

    184 Pages

  14. Bahia Optima

    4 Pages

  15. Dee Fly Cube

    20 Pages