SLOT DIFFUSERS LINED COMBINED SERIES - ALUMINIUM CONSTRUCTION • he combined air supply and exhaust components are aesthetically T combined on the same diffuser, with the same 25 mm-wide slots. • he air supply and exhaust deflectors are separated by a discreet T partition in the diffuser to deliver one of the lowest recycling rates on the market. • ir supply side: adjustable deflectors enabling horizontal diffusion A in one or two directions or vertical diffusion depending on the slots. The deflectors are located in the centre of each slot to ensure excellent air diffusion by the Coanda effect and a seamless aesthetic finish. • xhaust side: on the opening version a filter can be installed to E ensure filtration of fresh air before it reaches the ventilation unit installed. Opening core mounted on hinges and push clip closing method (minimum 3 slots). • vailable in Standard, TP or Slim linear versions to adapt to A different ceiling types and integration styles. O: air supply + exhaust (opening for access to filter using push clip system). F: air supply + exhaust fixed (non-opening, no filter). FINISH • luminium deflectors, paint coating RAL 7024 anthracite grey or A RAL 9010 white 30% matt. • nodised aluminium body, natural satin hue (STANDARD models A only) or paint coating, RAL 9010 white 30% matt. • aint finish from RAL colour chart. View the list of available P colours in the Compulsor air diffusion appendix. • pecial finish on request. S • iffuser and dedicated plenum for combined and simultaneous air D supply and exhaust, for all ventilation applications, especially air conditioning. • xtremely low internal and external recirculation / bypass rate E (<5%**) delivering excellent air diffusion efficiency and ensuring thermal and acoustic comfort of occupants. • djustable diffusion using dirigible deflector in the centre of each A slot. Vertical airflow possible. • ossible to add a filter on the exhaust part to replace that of the P ducted convector fan for example. • ptional possibility to add fresh air connection on exhaust to O ensure new air inlet for a convection fan. • Ceiling-mounted. Lined Combined Standard Opening Exhaust side Lined Combined Slim Fixed Exhaust side ACCESSORIES • alvanised steel plate connection plenum fitted with dividing partition between G the air supply and exhaust airflows. Simple or insulated version (sound proofing or thermal-acoustic insulation). Equipped with brackets for attachment to concrete slab. • ptional fresh air connection on exhaust side. O • ptional damper included in plenum, accessible from front of diffuser on non-TP O versions and without filters. • 3 M1 filter included in exhaust part of plenum for opening diffusers. G For more information, refer to the Combined plenum page below. STANDARD DIMENSIONS • to 8 slots on LINED COMBINED O versions, Length 500-1500 mm (600 to 1500 3 on TP model). • to 8 slots on LINED COMBINED F versions, Length 500-2000 mm (600 to 1600 1 on TP models). For more information, refer to the Range page. TECHNICAL DETAILS • ee selection tables and scales on following pages. S ATTACHMENT • oncealed attachment to plenum, either adjustable and accessible C below the diffuser (type S3), or directly using self-tapping screws on the sides of the plenum (type S2). ** Internal and external recycling rate. Tests carried out on 1000-1400 mm models, 3-5 slots, using in-house lab, compared to market leaders in linear combined solutions (air su
Open the catalog to page 1DIFFUSERS WITH FIXED ALUMINIUM SLOTS 147 LINED COMBINED SERIES - ALUMINIUM DIMENSIONS Air supply side Lined Combined Slim Fixed Air supply side Lined Combined standard and Combined slim - fixed and opening Number of slots
Open the catalog to page 2SLOT DIFFUSERS LINED COMBINED SERIES - STEEL CONNECTION PLENUM DIMENSIONS Plenum USE • lenums for LINED COMBINED series slot diffusers. P • ombined air supply and exhaust: minimum recirculation / bypass C rate (<5%**). • Ceiling-mounted. CONSTRUCTION • lenum specific to LINED COMBINED performing air supply and P exhaust functions simultaneously. • he plenum is divided into 2 equal parts for air supply and T exhaust intake. • he exhaust part is fitted with a filter which can be accessed via T the front panel of the diffuser. • ade of galvanised steel plate. M • ir supply and exhaust...
Open the catalog to page 3LINED COMBINED SERIES - STEEL CONNECTION PLENUM Lined Combined TP Opening Exhaust side Lined Combined TP Fixed Air supply side Lined Combined TP - Fixed and Opening Number of slots A (mm) - Length of Length of TBAR Length of FLINE Length of plenum B (mm) - Width of ceiling slab slot (mm) slot (mm) (mm) ceiling slab
Open the catalog to page 4SLOT DIFFUSERS LINED - LINED TP - LINED SLIM - LINED COMBINED SERIES ATTACHMENT AND FILTER REPLACEMENT Lined diffuser • ttachment using self-tapping screws on side of plenum. A Note: this attachment method is recommended for suspended ceilings and is not compatible with plaster or BA13 plasterboard ceilings. S3 ATTACHMENT METHOD • oncealed, adjustable attachment to plenum under the diffuser. C Note: this attachment method is simple and quick to use, with the possibility of adjusting the diffuser position in order to position it flush with the ceiling. Recommended for plaster or BA13...
Open the catalog to page 5DIFFUSERS WITH FIXED ALUMINIUM SLOTS Linear model Code TP model Code Slim model Code LINED S 11002297 LINED TP S 11002307 LINED Slim S 11002294 LINED E 11002298 LINED TP E 11002308 LINED Slim E 11002295 LINED EO 11002299 LINED TP EO 11002309 LINED Slim EO 11002296 Plenum for LINED 11002135 Plenum for LINED TP 11002114 Plenum for LINED Slim 11002136 Combined opening model Combined plenum LINED Combined plenum LINED Combined Slim O 11002378 LINED Combined Slim plenum 11002198 LINED Combined TP plenum Combined fixed model Combined plenum LINED Combined plenum LINED Combined Slim F 11002388...
Open the catalog to page 6DIFFUSERS WITH FIXED ALUMINIUM SLOTS Data valid for a standard diffuser (with central partition, so air supply length = exhaust intake length) The Lw (dB(A)) values do not take into account any noise attenuation in the room . Vt = 0.37 m/s Tests conducted with standard plenum API = air supply only AP2 = exhaust air only AP3 = exhaust with filter
Open the catalog to page 7All ALDES catalogs and technical brochures
-
TWISTED
5 Pages
-
MR MAX
6 Pages
-
Bahia Curve
8 Pages
-
ColorLINE®
1 Pages
-
AIR INLET RANGE
16 Pages
-
PLAFONE
4 Pages
-
LINED
16 Pages
-
DESIGN, DECO, IN LINE Axial fans
12 Pages
-
VELONE
15 Pages
-
Bap Color
4 Pages
-
General-Catalogue
664 Pages
-
RESIDENTIAL CATALOGUE
220 Pages
-
OPTIFLEX
40 Pages
-
In Line
20 Pages
-
Nano Air 50
8 Pages
-
Dee Fly Cube 550
12 Pages
-
InspirAir
20 Pages
-
EasyHOME®
60 Pages
-
COMPULSOR Casings and HRV units
131 Pages
-
Air Distribution compulsor
229 Pages
-
Air Diffusion Compulsor
270 Pages
-
COMPULSOR
184 Pages
-
Compulsor Habitat Ed.II
431 Pages
-
COMPULSOR Fire Protection
176 Pages
-
International Catalogue 2012/2013
580 Pages
-
Bahia Optima
4 Pages
-
Dee Fly Cube
20 Pages