Residential ventilation Selection guide H Design ^b Deco h In Line ^b Deco Design installation ^b In Line installation
Open the catalog to page 1SELECTION GUIDE Residential ventilation 4) 5 (A 4) Humidity detection Ideal for bathroom/ shower Occupancy detection Ceiling or wall Surface of room to ventilate or diameter of fan
Open the catalog to page 2Compliance • CE electrical safety. • Ng'WEEE recycling. Advantages • Ultra-flat design. • Silent from 26 dB(A). • Very low power consumption : from 5.6 W. • Available with occupancy detection. • Exists in 0 100, 125 and 150 mm V___J FIELD OF APPLICATION • Intermittent ventilation of a room. • Forced and intermittent air exhaust. DESCRIPTION • 3 diameters (mm): 100, 125 and 150. • Materials: outside wall terminal and body made of ABS. • Silent motor. • Removable backdraft damper at back of fan unit. • 4 operating modes: - Manual. - T = timer switch. - H = humidity detection (with timer...
Open the catalog to page 3DECO Compliance • CE electrical safety. • Ng'WEEE recycling. Advantages • Aesthetic and discreet. • Silent from 26 dB(A). • Very low power consumption : from 5.6 W. • White or aluminium finish. V_/ FIELD OF APPLICATION • Intermittent ventilation of a room. • Forced and intermittent air exhaust. DESCRIPTION • 2 diameters (mm): 100 and 125 • Material: ABS body, ABS grille with aluminium trim (for aluminium finish). • Silent motor. • Removable backdraft damper at back of fan unit. • White colour or aluminium finish. • 3 operating modes: - Manual. - T = timer switch. - H = humidity detection...
Open the catalog to page 4• CE electrical safety. • Ng'WEEE recycling. Avantages • Silent. • Air exhaust or air supply. • No fan in the room (fitted in the duct). FIELD OF APPLICATION • Intermittent ventilation of a room. • Used for exhaust or air supply. • Forced and intermittent operation. DESCRIPTION • 3 diameters (mm): 100, 125 and 150. • Material: ABS. • Silent motor. • Manual operation. • Supplied in cardboard box.
Open the catalog to page 5Axial fans DESIGN - DECO / DECO ALU INSTALLATION 1- Installation 2- Removable backdraft damper • onnection diameter: C Ø 100/125/150 mm (depending on model). • Fitted using 4 screws (supplied). • Wall or ceiling-mounted (fastening screws and plugs supplied). • Maximum temperature of exhaust air: 40°C 3- Wall or ceiling installation N Le produit doit être raccordé à un interrupteur (non fourni) N Le produit doitLe produit doit être raccordé à un(non fourni) (non fourni) être raccordé à un interrupteur interrupteur Le produit doit être raccordé à un Pour bien commencer... interrupteur (non...
Open the catalog to page 6Axial fans DESIGN - DECO / DECO ALU 5- Electrical connection and operation 1• Manual operation Immediate On/Off control using switch S. DECO 2 • Timed operation The extractor fan is activated using the switch S. Once turned off, the fan continues to operate for the time specified on the timer, between 2 and 30 minutes. DECO T Work with mains power off. Switch S not supplied.
Open the catalog to page 7Axial fans DESIGN - DECO / DECO ALU INSTALLATION 5- Electrical connection and operation (cont.) 3• umidity-controlled operation H DECO H The axial fan is activated using the switch S or when the humidity level H, pre-set between 60% and 90%, is exceeded. Once the fan is turned off or when the humidity level drops below the threshold, it continues to operate for the time specified on the timer (between 2 and 30 minutes). 4• Occupancy detection operation DESIGN P The fan is activated when movement of a person is detected within a radius of 1 to 4 m, within an angle of 100° horizontal to the...
Open the catalog to page 8Axial fans DESIGN - DECO / DECO ALU 6- Fresh air intake • equires an air inlet terminal (with air R passage S) or a door undercut (height H). Ø 7- Authorised installation locations • Prohibited in area 1. 8- Maintenance Work with mains power off. Clean regularly the fan grille with soapy water. Clean the fan unit using a soft damp cloth. Carefully wipe dry all surfaces. Do not submerge the unit in water.
Open the catalog to page 9IN LINE INSTALLATION 1- Installation 2- Installation on wall or ceiling Installation inside a duct. Maximum temperature of exhaust air: 40 °C Requires an air inlet terminal or door undercut for correct ventilation of the room. 4- Electrical connection and operation Manual operation Immediate On/Off control using switch S. A Work with mains power off. Switch S not supplied.
Open the catalog to page 10IN LINE6- Fresh air intake • Requires an air inlet terminal (with air passage S) or a door undercut (height H). 8- Maintenance A Work with Clean regularly the terminal with soapy water. Clean the fan unit using a soft damp cloth. mains power Carefully wipe dry all surfaces. off. Do not submerge the unit in water.
Open the catalog to page 11Residential ventilation DESIGN, DECO, IN LINE Axial fans Fields of application • Forced and intermittent air exhaust. Installation • Ideal for renovating existing buildings. • Can be installed on a wall, ceiling or in a duct. Advantages • Silent: from 26 dB(A). • Very low power consumption. • Easy to install and use. • Multiple operating modes. Extracteurs_Tech_Corp_Gb_1 - Aldes reserves the right to make changes to its products due to technical developments. - RCS Lyon 956 506 828
Open the catalog to page 12All ALDES catalogs and technical brochures
-
TWISTED
5 Pages
-
MR MAX
6 Pages
-
LINED COMBINED SERIES
7 Pages
-
Bahia Curve
8 Pages
-
ColorLINE®
1 Pages
-
AIR INLET RANGE
16 Pages
-
PLAFONE
4 Pages
-
LINED
16 Pages
-
VELONE
15 Pages
-
Bap Color
4 Pages
-
General-Catalogue
664 Pages
-
RESIDENTIAL CATALOGUE
220 Pages
-
OPTIFLEX
40 Pages
-
In Line
20 Pages
-
Nano Air 50
8 Pages
-
Dee Fly Cube 550
12 Pages
-
InspirAir
20 Pages
-
EasyHOME®
60 Pages
-
COMPULSOR Casings and HRV units
131 Pages
-
Air Distribution compulsor
229 Pages
-
Air Diffusion Compulsor
270 Pages
-
COMPULSOR
184 Pages
-
Compulsor Habitat Ed.II
431 Pages
-
COMPULSOR Fire Protection
176 Pages
-
International Catalogue 2012/2013
580 Pages
-
Bahia Optima
4 Pages
-
Dee Fly Cube
20 Pages