Catalog excerpts
COMPULSOR Fire Protection Compartmentalisation Mechanisms Surface-mounted ISONE+ dampers Flush-mounted ISONE+ dampers ISONE 1500 dampers MINiSONE dampers Terminal dampers
Open the catalog to page 1Fire protection Compartmentalisation Fire dampers Leader in the French market, ALDES has already delivered more than a million fire dampers, which have includes a variety of innovative features, such as: - A surface-mounted version, which can be installed without having to be sealed, thus remaining removable, - An unequalled ability to upgrade the ISONE mechanism, - A new range - subjected to fire resistance testing at 1500 Pa, - An 'ALDES Control' pack to simulate the Fire Safety Control Unit (CMSI) prior to finalising the connections. ALDES also supplies fire dampers for specific uses such as...
Open the catalog to page 2The regulatory environment for fire dampers is changing For over 10 years, the European Union has been gradually implementing the "Construction Products" directive on a product by product basis. Today, it is the turn of fire dampers to respect marking. This new regulation may disrupt the habits of stakeholders in the fire protection industry. In particular these changes concern: • New fire resistance testing and classification methods. • New European vocabulary concerning fire resistance. Fire protection FROM A TECHNICAL STANDPOINT, WHAT CHANGES AFFECT FIRE DAMPERS? The answer is...
Open the catalog to page 3Fire protection Compartmentalisation ISONE mechanisms : fully adaptable in just a few minutes! Since 1984, all ALDES dampers have been upgradeable. This means that, once installed, the damper mechanism can be improved by fitting an electromagnetic tripping device, one or more signalling contacts and a reset motor. The dampers can therefore be adapted to match changing regulatory requirements and operational needs. With the ISONE mechanism, upgradeability is simplified to the limit! Thanks to plug-in, tool free fittings, the ISONE mechanism can be transformed into its most complete version...
Open the catalog to page 4EHOP 30S remote reset motor Ensure the damper is in safety position prior to any intervention. Attention: To reset the damper, the airflow must be zero. Pin descends into housing 2 Characteristics • Voltage: 21 to 53 V DC and AC. • Maximum current: - 0.7 A under 24 V, - 0.35 A under 48 V. REMINDER: the power supply must be Very Low Safety Voltage. • Reset in 10 sec. • Automatic stop at end of cycle. • 2 seconds of stop time between 2 cycles. • Operating temperatures: -10 to +50 °C. • Service life: 1500 operations. • Maintenance-free. • The output impeller rotates freely when the motor is...
Open the catalog to page 5Fire protection Compartmentalisation ISONE fire damper mechanism ISONE+: fully adaptable in just a few minutes! Advantages • Upgradeable mechanism: all equipment can be installed/removed at any time; operations can be carried out single-handed without tools. • 24 or 48 V?: control errors rendered impossible by bi-voltage trip device. • Easy to connect: all ISONE terminals are fitted with fool-proof devices and can be disconnected without tools. • The ISONE mechanism can be fitted with all tripping, signalling & reset equipment, either in the factory or on-site at a later date. • All this...
Open the catalog to page 6Fire protection ISONE fire damper mechanism The signalling contacts are fitted to printed circuit boards. All boards are clipped into the mechanism housing and can be removed easily and quickly without tools. The connector terminals are fitted with fool-proof devices and can be removed easily. • PCB No.1 - FCU1 - DCU1 Reserved for dampers with Thermal Fuse (FTE) only. Includes a choice of: - End of travel contact FCU1 (shows that the damper is closed), - Start of travel contact DCU1 (shows that the damper is open), - Both contacts FCU1 + DCU1. • PCB No.2 - motor electromagnet Adapted to...
Open the catalog to page 7• Isone+ EM or FDP fire dampers can house the BF/ BLF mechanism. • The BF/BLF motor moves the damper to the operating position at the same time as tensioning the return spring. The damper is turned back to the safety position by spring energy when the supply voltage is interrupted. • Thermo-electric fuse 72°C (BAE72) for BF/BLF mechanism. • Manual or motorize reset. • 24 V or 230 V. • IP 54 • FC/DC signalling contacts (open/closed position). Fire protection ISONE+ fire dampers can house the BF/BLF mechanism! BF/BLF Mechanism BLF 24 V - Contacts are illustrated on standby BLF 230 V -...
Open the catalog to page 8Summary table of fire resistance properties of ISONE+ fire dampers Type of Fire damper Thin plasterboard partition wall EI 90 S (CF 1h30) 500 Pa Ve (1hr or 2 hr wall) o i Fire protection Rectangular surface-mounted ISONE+ Type of Fire damper 110 mm concrete EI 120 S (CF 2hr) 500 Pa Ve (wall) Ho (slab) o i EI 120 S (CF 2hr) 500 Pa Ve (wall) Ho (slab) o i EI 90 S (CF 1h30) 500 Pa Ve (wall) o i Vane axis: horizontal EI 120 S (CF 2hr) 1500 Pa Ve (wall) Ho (slab) up to 600 x 600 o i Vane axis: horizontal Supplement for COMPULSOR Fire Protection Edition n° 8 Circular surface-mounted ISONE+
Open the catalog to page 9Fire protection Compartmentalisation surface mounted fire damper Circular & rectangular surface-mounted ISONE+ Advantages • Easy and cheap to install, no sealing or suspension elements required. • On 70 mm plasterboard tiles. • On lightweight plasterboard partitions. • Onto offset GEOSTAFF ducts. • Airtight - Class B from EN 1751. AVAILABLE OPTIONS • Compartmentalisation of commercial premises (Public buildings, High rise buildings, commercial or industrial premises etc.). • EI 60 S - on CF 1h wall. • EI 90 S - on plasterboard + rail wall 1hr30 or 2hr. • EI 120 S on offset GEOSTAFF duct. •...
Open the catalog to page 10surface mounted fire damper Fire protection MECHANISM POSITIONING UNIMPORTANT INSTALLATION PRINCIPLES Supplement for COMPULSOR Fire Protection Edition n° 8 • Installation on plasterboard partitions with metallic rails. See page 11. • Installation on plasterboard tiles. See page 14. • Installation on offset ducts. See page 15. • Aeraulic connection. The two metallic sleeves on the ISONE are both MALE. The sleeves should be attached without mechanical pressure and should enable perfect alignment of the ducts with the damper. • The installation of the ISONE Ap requires no sealing, suspension...
Open the catalog to page 11All ALDES catalogs and technical brochures
-
TWISTED
5 Pages
-
MR MAX
6 Pages
-
LINED COMBINED SERIES
7 Pages
-
Bahia Curve
8 Pages
-
ColorLINE®
1 Pages
-
AIR INLET RANGE
16 Pages
-
PLAFONE
4 Pages
-
LINED
16 Pages
-
DESIGN, DECO, IN LINE Axial fans
12 Pages
-
VELONE
15 Pages
-
Bap Color
4 Pages
-
General-Catalogue
664 Pages
-
RESIDENTIAL CATALOGUE
220 Pages
-
OPTIFLEX
40 Pages
-
In Line
20 Pages
-
Nano Air 50
8 Pages
-
Dee Fly Cube 550
12 Pages
-
InspirAir
20 Pages
-
EasyHOME®
60 Pages
-
COMPULSOR Casings and HRV units
131 Pages
-
Air Distribution compulsor
229 Pages
-
Air Diffusion Compulsor
270 Pages
-
COMPULSOR
184 Pages
-
Compulsor Habitat Ed.II
431 Pages
-
COMPULSOR Fire Protection
176 Pages
-
International Catalogue 2012/2013
580 Pages
-
Bahia Optima
4 Pages
-
Dee Fly Cube
20 Pages