Heating

Heating
1 / 80 PagesView full catalog

Heating

Product catalog summary
Overview
This document provides comprehensive technical specifications and performance data for various heat pump models, including PAC BT Monobloc and Split systems, as well as PAC HT high-temperature heat pumps. These systems are designed for both cooling and heating applications, suitable for new constructions and refurbishments.
Specifications
  • Monobloc Systems: Available in low and high-temperature variants, with capacities ranging from 5 kW to 16 kW for low temperature and up to 18 kW for high temperature.
  • Split Systems: Designed for both new builds and refurbishments, offering similar capacities as Monobloc systems.
  • Operating Temperatures: Heating mode operational down to -20°C outdoors, cooling mode up to 46°C.
  • Energy Efficiency: High COP (Coefficient of Performance) up to 4.85 and EER (Energy Efficiency Ratio) up to 4.55, with energy efficiency class A++.
Features
  • DC Inverter compressor for high flexibility.
  • Digital display for mode selection, weekly timer, and diagnostics.
  • Compact design with safety features like safety valve and expansion tank.
  • Auxiliary heat resistance included in some models.
Performance Data
  • Heating capacities range from 4.58 kW to 16.33 kW depending on the model and water regime.
  • Cooling capacities range from 4.55 kW to 15.1 kW.
  • Graphs illustrate capacity variations with outdoor temperature changes for both heating and cooling modes.
Technical Data
  • Single-phase and three-phase models available, with different power inputs and COP values.
  • Refrigerant type used is R410A.
  • Sound levels vary between 61 dB(A) to 71 dB(A) depending on the model and mode.
  • Dimensions and weight specifications provided for each model.
Recommendations
  • Ideal for replacing old monobloc heat pumps with a "Plug & Play" solution.
  • Suitable for radiant panel heating and cooling, low-temperature heaters, or fan-coil units.
Installation and Protection Recommendations
The document emphasizes the importance of installing a dirt separator and filter sieve upstream of the heat pump to prevent molding and ensure optimal thermal exchange. A drain valve is recommended at the buffer volume's bottom for sediment evacuation.
Manometers on Circulators
Each circulator should have a manometer with two isolating valves to measure pressure and evaluate flow based on the circulator's specific curve.
General Recommendations
Before starting up, ensure the system is complete, the refrigeration circuit is emptied and charged, and the water circuit is loaded and vented. Electrical connections should be checked. Protection against temperatures below 15°F is advised, and a water softener may be necessary. To prevent freezing, lay tubes below the frost line and provide windbreaks.
Domestic Hot Water Requirements
Hot water requirements vary based on the number of occupants. Average daily consumption is estimated per person for bathroom and kitchen use, with low, medium, and high categories. An auxiliary cylinder can be added for high demand.
System Components
The document lists various components such as dirt separators, water filters, pressure gauges, descaler protection, solar pumps, and expansion tanks. Each component has a specific role in maintaining system efficiency and safety.
Zone Control and Energy Saving
The air/air heat pump system features zone control, allowing temperature regulation in up to six rooms. Energy savings are achieved through an inverter system and motor speed reduction when the desired temperature is reached.
Design and Installation Features
The DLSE Plus VAV system includes a unique V shape coil for performance and compact design, a horizontal fan for higher air volume, and easy installation features such as simple wiring and built-in water pump and overflow switch.
Ordering and Accessories
For installation, select the damper type and main controller setup. Accessories like motorized round dampers and plenums are available for customization.
Environmental Considerations
The document mentions Airwell's eco-environmental approach, including life cycle analysis and compliance with ISO standards for environmental performance.
Additional Products
Information on thermodynamic water heaters is included, detailing features such as anti-legionella functions, safety measures, and ease of installation. Technical data for different models are provided, including COP, heating capacity, and dimensions.
See more

Catalog excerpts

Heating-2

Contact Us An international sales network www.airwell-res.com Contact details [ HEADQUARTERS ] 3, avenue du Centre - Les Quadrants - Batiment A 78280 Guyancourt - FRANCE [ DOCUMENT LIBRARY ] http://lh.airwell-res.com [ COMMERCIAL ] E-mail: [email protected] Tel: +33 (0)1 76 21 82 00 [ AFTERSALES ] SPARE PARTS ORDERS ■ E-mail: [email protected] TECHNICAL SUPPORT ■ E-mail: [email protected] Tel: +33 (0)1 76 21 82 95 Monday to Friday: from 9:00 am to 12:30 pm and from 2:00 to 5:00 pm

 Open the catalog to page 2
Heating-3

/\iriueIL Just feel Weii Table of contents ; PAGE HISTORY 4 AIR TO WATER HEAT PUMPS RANGE 20 PAC BT Split Low temperature heat pump with DHW tank included 32 AIR TO AIR HEAT PUMPS RANGE DLSE+VAV Ducted medium static pressure monosplit THERMODYNAMIC WATER HEATERS RANGE TDF 190/1.5 180-L ducted water heater TDF 300/3.5 280-L ducted water heater ICONS GUIDE

 Open the catalog to page 3
Heating-5

Just feel well The beginning of the Airwell’s story, a french air conditioning brand. The firm developed and began the mass production of the first window unit, to offer exceptional climate conditions, mainly dedicated to European and African markets. Airwell developed a split system unit by splitting its core window unit in two parts. It was the first to produce wall split systems in Europe. Implantation of historical plant Tillières-sur-Avre in France. The company designed and produced the first European wall split system range including electronic remote control, a high technology cross-flow...

 Open the catalog to page 5
Heating-6

Services division The training solution for installers Training courses In partnership with its customers, Airwell Residential provides you with Airwell Academy centers for presentations and training, both in France and worldwide. Training courses are regularly offered to present the brand’s product range and unique solutions. New centers are due to open throughout the year. For all training requests, please contact us at the following e-mail address: n [email protected]

 Open the catalog to page 6
Heating-7

/\iriueIL Just feel Weii wAir conditioning • Residential air conditioning • Light commercial air conditioning • Air conditioning systems regulation Heating Residential heating Light commercial heating Heating systems regulation Statutory trainings Solutions for hospitals Solutions for hotels Residential solutions Anti-legionellosis solutions Water treatment Sales training Energy performance Design offices Installers Architects Read more on our website: ■ www.airwell-res.com

 Open the catalog to page 7
Heating-8

Services division Pre-sales Airwell Residential supports you throughout your projects (housing units, hotels, shops, industrial sites, etc.). Before your plans are implemented, the pre-sales department studies your residential or industrial project to recommend the best technical solution. Using selection software, the pre-sales engineer estimates and measures the dimensions of your air conditioning system. e-mail: [email protected]

 Open the catalog to page 8
Heating-9

Just feel well Installation / Commissioning CALL CENTRE q Quick, useful response from our experts q Multilingual call centre q Professionals who constantly benefit from training q A customer-based, service-orientated approach! q As much attention and help as required for the customer to be fully satisfied LOCAL AND REMOTE TECHNICAL SERVICE (WORLDWIDE) q pecialized and experienced technicians S q irect contact by telephone; on-site contact for VIP customers if required D Technical Station approved by SPARE PARTS SERVICE q lobal warehouse in France G Tel. +33 (0)1 76 21 82 95 SPARE PARTS ORDERS:...

 Open the catalog to page 9
Heating-10

unique heating range ■ Air to water heat pumps range ■ Air to air heat pumps range ■ Thermodynamic water heaters

 Open the catalog to page 10
Heating-11

/\iriueIL Just feel Weii The exclusive and unique solution thanks to a complete offer. q Modularity second to none q A global offer of products and services HEAT AND/OR DHW PRODUCTION

 Open the catalog to page 11
Heating-13

Just feel well Principle of the heat pump Heat pumps collect heat from outside the home, concentrate this heat and return it into the home. Heat exchanges in a heat pump are related to changes of state. W hen a liquid boils, it absorbs heat. W hen a gas condenses, it releases this heat. q he heat is drawn from the heat source: outside air. T q is therefore necessary to use a fluid which can change state at pressures that are compatible with It the operation of the temperature and pressure compressors. STANDARD REFRIGERANT CIRCUIT Heat pump COLD SOURCE Expansion valve starting temperature: from...

 Open the catalog to page 13
Heating-15

Just feel well HEAT PUMP SELECTION We recommend you to use a configuration with a back-up boiler (electrical or fossil energy) to optimize material cost and performances. q ACK-UP BOILER CONFIGURATION B An Airwell heat pump can adapt to any type of issuers, namely floor heating radiators at low/medium temperature (55°C) as well as for high temperature radiators (65°C). In the case of a heat pump with back-up* (electric or boiler) it is necessary to define what is known as the equilibrium point, which matches to the outdoor temperature below which the heat pump heats the home jointly with the...

 Open the catalog to page 15
Heating-16

Heat pumpsDHW POWER CALCULATION Needs for Domestic Hot Water Preparation with pure accumulation: the DHW is produced in 6 or 8 hours. Equivalent volume at 60°C : with: Tx : Storage temperature of the DHW tank Vx : water volume at storage temperature Tx Step 1: Drawn energy during the day It consists in calculating the maximum volume of hot water (equivalent to 60°C) drawn during the highest day of the year. The energy drawn via hot water is given by the formula: ( 'v with: Eacc = drawn energy during a full day in kW/h V60acc = total hot water drawn during a day, including all usage,...

 Open the catalog to page 16
Heating-17

Just feel well REGULATION OF LOW TEMPERATURE HEAT PUMP PAC BT T he PAC BT range is equipped by DC Inverter compressor to meet needs. Comfort and seasonal efficiency (Inverter compressor) CAPACITY MODULATION 14 Heat pump Compressor On-Off COP 2,7 Heating capacity [kVVt] • Optimized running at partial load = Higher COP • Heating capacity = Heating needs Inverter modulation zone Thermal load Hours of the occurrence of specific outside temperature PAC BT works for most of the time ith w COP etween 3 and 5 b Boiler back up regulation There are two possibilities to regulate with boiler back up: integration...

 Open the catalog to page 17

All AIRWELL catalogs and technical brochures

  1. PAC HT

    4  Pages

  2. PAC BT

    8  Pages

  3. 2019 HEATING

    56  Pages

  4. Air conditioning

    148  Pages

  5. NDLP

    1  Page

  6. DK-DN

    2  Pages

  7. X AR

    2  Pages

  8. AQVL/AQVH

    2  Pages

  9. CWP HP

    2  Pages

  10. MQL / MQH

    2  Pages

  11. VHF

    2  Pages

  12. XLM OG

    2  Pages

  13. AQU@FAN II

    2  Pages

  14. K OG

    4  Pages

  15. CRWC/CRWN

    16  Pages

Archived catalogs

  1. SAF 024-045

    2  Pages

  2. had

    2  Pages

  3. DAKOTA WDI

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.