The QuietAir fan warranty is valid in the UK for two years, extendable to three years with registration on the Airflow website. It covers the product only, excluding installation costs, and is contingent on proper installation, use, and no unauthorized modifications.
General Information
This document provides safety and operational instructions for the QuietAir 100mm Axial Fan, model QT 100HT. It stresses adherence to safety regulations and proper installation for optimal performance and safety. The fan is intended for air extraction in living spaces and must comply with relevant standards and regulations.
Installation Instructions
Installation requires site preparation, correct cable exit, drilling, and securing the fan to the wall or ceiling. It should be installed after other work is completed to prevent damage. Detailed steps for cable connections are provided, emphasizing the need for a certified electrician.
Electrical Connection
Electrical connections must be isolated from the power supply and performed by a certified electrician according to the wiring diagram. The fan is IPX5 rated and complies with safety class II standards.
Cleaning and Maintenance
Regular cleaning and maintenance are essential for longevity and performance. The fascia can be dismantled for cleaning.
Fault Diagnostics
A troubleshooting section addresses common operational issues.
Environmental Considerations
Dispose of the product responsibly following local recycling guidelines for electrical equipment.
Installation and Operation Instructions
1. Installation Guidelines
Ensure pre-cut drillings are punched through when installing in the ceiling to prevent condensate formation. The guide vane with a back draught shutter can be mounted or omitted as needed. Ensure vertical affixation of rubber foam and a 7 mm clearance for the fascia.
2. Electrical Connection
All electrical work must be isolated from the power supply and performed by a certified electrician. The fan should not be used with transformer controllers. Follow all safety regulations and national standards. The electronic control board includes automatic humidity control and a timer in a splash-proof casing. Additional suppression shielding may be needed for electromagnetic compatibility.
3. Cleaning and Maintenance
Isolate the fan from the power supply before cleaning. Use a damp cloth only. The fan is maintenance-free. To dismantle the fascia, isolate the device, remove the fascia with a screwdriver, and unfasten the control board cover screws.
4. Troubleshooting
Common issues include thermal protection trips due to dirt or high winding temperature, abnormal noises from worn bearings, vibrations from an unbalanced impeller, and performance reduction due to high resistance in the ventilation system.
5. Wiring and Functionality
The fan requires a permanent supply voltage of 230v/1Ph/50-60 Hz connected to terminals N and L. Terminal 1 provides a 2-minute delay start, 15-minute timer overrun, and humidity sensor activation. Terminal 2 allows operation at a second speed via a second switch. Both terminals can be used for combined functionality. The fan enters test mode for 1 minute upon initial start-up, and the humidity sensor requires about 1 hour to calibrate.
6. Additional Functionality
The humidity sensor can be temporarily deactivated for 1 hour with a short switch pulse. Terminal speeds can be adjusted between 75m³ and 90m³. DIP switch settings can be changed to modify functionality, such as disabling the time delay or adjusting humidity levels. Always isolate the unit from the mains before making changes.
7. Important Notes
When connecting the fan to the light switch, use a double-pole switch. Wiring in series of more than one fan is not permitted.
See more

Catalog excerpts

QuietAir 100mm Axial Fan-1

Model_QT_100HT 29/07/2009 18:22 Page 1 Warranty: Applicable to units installe! and used in the United Kingdom. Airflow's Warranty covers the QuietAir fan for TWO years. The Warranty can be upgraded to THREE years from date of purchase against faulty material or workmanship by registering on our web site at www.airflow.com. The Warranty covers the product only and not the installation cost.. In the event of any defective parts being found, Airflow Developments Ltd reserve the right to repair or at our discretion replace without charge provided that the unit 1. Has been installed and used in accordance with the fitting and wiring instructions supplied with each unit 2. Has not been connected to an unsuitable electrical supply 3. Has not been subjected to issue, neglect or damage. 4. Has not been modified or repaired by any person not authorised by Airflow Developments Ltd. 5. Has been installed in accordance with latest Building Regulations and IEE wiring regulations. Airflow Developments shall not be liable for any loss, injury or other consequential damage, in the event of a failure of the equipment or arising from, or in connection with, the equipment excepting only that nothing in this condition shall be construed as to exclude or restrict liability for negligence. This warranty does not in any way affect any statutory or other consumer rights. AIRFLOW O SPECIALISTS IN AIR MOVEMENT TECHNOLOGY Airflow Developments Limited Lancaster Road, Cressex Business Park High Wycombe, Buckinghamshire HP12 3QP, United Kingdom E-mail: [email protected] Telephone: +44 (0) 1494 525252 Facsimile: +44 (0) 1494 461073 airflow.com

 Open the catalog to page 1
QuietAir 100mm Axial Fan-2

Model_QT_100HT 29/07/2009 18:22 Page 2 9041265 RF SPECIALISTS IN AIR MOVEMENT TECHNOLOGY Installation and Operating Instructions QuietAir 100mm Axial Fan MODEL:QT 100HT - Two Speed Fan (75/90m3/hr) with Delay Start, Automatic Humidity control and Timer Low Energy Օ Whisper Quiet Long Life Օ Extra Safe Delay Start IP45Aըh ec a 11 w RANGE

 Open the catalog to page 2
QuietAir 100mm Axial Fan-4

Model_QT_100HT 29/07/2009 18:22 Page 4 Installation and Opration Instructions QuietAir 100HT CHAPTER1 INSTALLATION AND OPERATING 1.0 Important information To ensure safety and correct opration please read and observe the following instructions carefully before proceeding. The electrical connection must be fully isolated from the supply up to the final assembly ! Keep the installation and operating instructions as a reference at the device. After the final assembly the document must be handed out to the operator (tenant/owner). 1.1 Warning and safety instructions Accompanying symbol is a safety-relevant...

 Open the catalog to page 4
QuietAir 100mm Axial Fan-5

Model_QT_100HT 29/07/2009 18:22 Page 1 Installation and Operation Instructions 1.10 Electrical connection All work must be carried out with the equipment fully isolated from the power supply. The electrical connection are to be carried out in accordance with the relevant wiring diagram and are only to be done by a certified elec-trician. The electrical connection must be fully isolated from the supply up to the final assembly ! All relevant safety rgulation, national standards and norms are to be adhered to. An appliance is required for eut off from the supply with a minimum of 3 mm contact opening...

 Open the catalog to page 5
QuietAir 100mm Axial Fan-6

Model_QT_100HT 29/07/2009 18:22 Page 2 Installation and Operation Instructions 3.3 Wall or ceiling installation With installation of the device, the guide vane (5) must be mounted jvertically (as shown). Snaps into place every 90° rotation. Break out entry knockout for cable. fig.4 Affix the rubber foam Back draught shutter (6) removable Guide vane (5) removable If installed in the ceiling the pre-cut drillings (2) must be punched through because of possible condensate formation. 3.4 Cable connections 1. Pull cable through grommet, don't cut open! 2. Cut cable at least to length 180 mm and remove...

 Open the catalog to page 6
QuietAir 100mm Axial Fan-7

Model_QT_100HT 29/07/2009 18:22 Page 3 Installation and Operation Instructions CHAPTER 4 4.0 Electrical connection ELECTRICAL CONNECTION All work must be carried out with the equipment fully isolated from the power supply. The electrical connection is to be carried out in accordance with the relevant wiring diagram and are only to be done by a certified electrician. The fan may not be operated with transformer controllers. All relevant safety rgulation, national standards and norms are to be adhered to. WARNING 4.1 Electronic control board PCB with automatic humidity control and timer. The control...

 Open the catalog to page 7
QuietAir 100mm Axial Fan-8

Model_QT_100HT 29/07/2009 18:23 Page 4 Installation and Opration Instructions Wiring diagram overview Connection client Internai functional principle / Jumper position SS-931 SS-919 NL 12 75(90) m*0@ 90(75) m3/h i] msnucu on WARNING Terminal N/L: A permanent supply voltage of 230v/1Ph/50-60 Hz should be connected to terminals N and L, for ALL installations. The unit is double insulated and does not require an earth. (drawing SS-919) You need an additional switched live to Terminal 1 OR/AND Terminal 2 to give your fan its functionality. Terminal 1 Functionality Factory set 2 minute delay start,15...

 Open the catalog to page 8

All Airflow Developments catalogs and technical brochures

  1. Instruments

    4  Pages

  2. iCONstant

    4  Pages

  3. Hand Dryers

    5  Pages

  4. Industrial Fans

    15  Pages

  5. LOOVENT eco

    8  Pages

  6. Aura-eco 100T

    2  Pages

  7. fans blowers

    2  Pages

  8. fans

    2  Pages

  9. flue dilution

    6  Pages

  10. Loovent CV

    2  Pages

  11. Aura-eco 150B

    2  Pages

  12. Aura B

    2  Pages

  13. iCON 60

    2  Pages

  14. iCON 15

    2  Pages

  15. AVENTA TURBO

    9  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.