Catalog excerpts
SAP-APPENDIX Q ELIGIBLE ovent hvs Continuous low cost ventilation for the whole house. Airovent HVS 10 is designed to provide extraction levels that comply with the latest Building Regulations 2010 (PART F). The HVS-10 is an exceptionally quiet and energy efficient whole house ventilation system. It has 14 easily adjustable speed settings for comprehensive control suited to the individual requirements of the dwelling. Model HVS-10 R comes with a remote control and built-in humidity sensor for full automation. By continuously extracting stale, moist air from the whole house, the Airovent ventilation system creates a healthier indoor environment. This helps to alleviate the problems of dampness and condensation, so benefiting both the fabric of the building and occupant health. Features: -Ultra low energy. -Designed for continuous operation. -Simultaneous extraction from multiple rooms. -14 speed settings for exceptionally close control. -Low noise, long life motors. -Four inputs for duct connections. -HVS-10R comes with a remote control module (with humidity sensor). -Optional accessories for humidity and timer control. -Ducting, grilles and flow control valves available. -Low specific fan power from 0.25 w/l/sec. Designed to provide efficient ventilation whilst saving energy, the ultimate solution for whole house ventilation... Key Features - 2 years warranty. - 14 step speed control. - Extracts air from multiple rooms simultaneously. - SAP Appendix Q Eligible Application For use in both new and refurbished houses, flats, apartments and sheltered accommodation. Airovent HVS-10 Part No: 72649601 Airovent HVS-10R (with remote control and humidity sensor) Part No: 72649701 For more information please visit airflow.com or email us at info@airflow.co.uk or call 01494 560800 AIRFLOW
Open the catalog to page 1Standard Assessment Procdure - Appendix Q Centralised MEV Product Data 01/05/2008 SAP Appendix Q Testing Results Central exhaust ventilation system packages used in a single dwelling Brand Name Airflow Model HVS-10 Model Qualifier (if applicable) Current Manufacturer and Contact Details Name Airflow Developments Ltd Address Lancaster Road Cressex Business Park High Wycombe HP12 3QP Telephone 01494 525252 Website www.airflow.co.uk Original Manufacturer (if different) First Year of Manufacture 2008 Last Year of Manufacture Testing Body BRE Date of test Serial Number of Product Tested...
Open the catalog to page 2Standard Assessment Procdure - Appendix Q Centralised MEV Product Data 01/05/2008 Results for SAP calculations (at minimum flow rate condition) This product has only been tested with rigid ductwork and it is not applicable for SAP _Appendix Q if installed with flexible ductwork._ Standard Assessment Procedure - Appendix Q Centralised MEV Product Data 01/05/2008 Table Q1 - Systems with rigid ductwork only Exhaust terminal Fan speed Specific fan Energy Saving Trust Best configuration setting power (W/l/s) Practice Performance Compliant Kitchen + 2 0.26 Yes 1 additional wet room Kitchen + 2...
Open the catalog to page 3Standard Assessment Procdure - Appendix Q Centralised MEV Product Data 01/05/2008 Table Q2 - Systems with flexible ductwork only Exhaust terminal configuration Fan speed setting Specific fan power (W/l/s) Energy Saving Trust Best Practice Performance Compliant Kitchen + 1 additional wet room N/A N/A N/A These figures are entered into either: (a) In the case of SAP software amended to SAP 2005 version 9.81 allowing direct entry of centralized MEV data, the SAP software, or (b) In the case of SAP software amended to SAP 2005 version 9.81 not allowing direct entry of MEV data, the SAP Q MEV...
Open the catalog to page 4Standard Assessment Procdure - Appendix Q Centralised MEV Product Data 01/05/2008 Results for Approved Document F (at maximum flow rate condition) Table Q3 Exhaust terminal Fan speed Total flow Total flow rate - % reduction configuration setting rate wind condition of total flow (l/s) (l/s) rate Kitchen + 2 29.3 27.4 6 1 additional wet room Kitchen + 2 29.3 27.4 6 2 additional wet rooms Kitchen + 3 37.9 36.3 4 2 additional wet rooms Kitchen + 4 45.7 43.7 4 2 additional wet rooms Comments Only figures from Table Q1 or Table Q2, not both, should be used with the SAP Q Calculation Spreadsheet...
Open the catalog to page 5Airovent HVS Why Ventilate? AIRFLOW fans exceed the requirements of the latest building rgulations helping to combat the harmful effects of dampness and condensation and by extracting airborne pollutants such as odours, cooking smells, humid and stale air. The potential hazards to health for occupants and possible damage to the fabric of the building can be largely eliminated. t-2DS- - IZJ- Unit Dimensions (mm) -r ,* .ni Electrical supply: 230 V/1PH/50Hz Accessories Airese flow control valves to regulate individual room extraction. For more information please visit airflow.com or email us...
Open the catalog to page 6All Airflow Developments catalogs and technical brochures
-
Instruments
4 Pages
-
Whole House Ventilation
5 Pages
-
iCONstant
4 Pages
-
Residential Heat Recovery
30 Pages
-
Hand Dryers
5 Pages
-
Industrial Fans
15 Pages
-
Commercial Heat Recovery
19 Pages
-
Residential Fans
32 Pages
-
LOOVENT eco
8 Pages
-
Ventilation solutions
8 Pages
-
Aura-eco 150HT
2 Pages
-
Aura-eco 100T
2 Pages
-
QuietAir 100mm Axial Fan
8 Pages
-
fans blowers
2 Pages
-
fans
2 Pages
-
flue diltution
6 Pages
-
flue dilution
6 Pages
-
Loovent CV
2 Pages
-
Aura-eco 150B
2 Pages
-
100B and 150B Basic Aura ECO
1 Pages
-
Aura In-line 100T
2 Pages
-
Aura B
2 Pages
-
iCON 60
2 Pages
-
iCON 15 Shower Kit
2 Pages
-
iCON 15
2 Pages
-
AVENTA TURBO
9 Pages
-
QuietAir QT100B
2 Pages
Archived catalogs
-
Residential Heat Recovery
16 Pages