SmartCool™ 16-233kW Sales Brochure (English)
16Pages

{{requestButtons}}

Catalog excerpts

SmartCool™ 16-233kW Sales Brochure (English) - 1

SmartCool™ 16 - 233kW INCLUDES NEW 16 – 60KW RANGE: + 17% more cooling kW/m2 + EER 34% more efcient* * Compared with our previous generation CRAC units WATER COOLED CHILLED WATER SCROLL COMPRESSOR INVERTER COMPRESSOR DUAL COOL FREE COOL FREE-COOLING www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY

Open the catalog to page 1
SmartCool™ 16-233kW Sales Brochure (English) - 2

Precision air conditioning Taking efciency even further The SmartCool™ is a next generation, highly efcient, indoor packaged unit providing extremely precise, reliable climate control. Applied cutting edge technology enables the SmartCool™ to quietly and precisely control room temperature, humidity and air quality to ensure efcient, reliable, 24/7 operation of sensitive systems in data centres and other critical applications. Optimise your unit selection The SmartCool™ gives you the exibility to optimise unit selection to match the considerations of your specic project – whether a new or...

Open the catalog to page 2
SmartCool™ 16-233kW Sales Brochure (English) - 3

Energy saving with free-cooling* Free-cooling, dual cool SmartCool™ less energy Saving up to £8,000/year or 31,000kg of CO2 compared with a standard DX system (£0.11/kWhr) Free-cooling dual cool * Annual cumulative kW hours based on a constant 50kW load and average ambient figures for London, UK at 24ºC/45% RH Saving energy and carbon, reducing operating costs Designed for maximum efciency, SmartCool™ precision air conditioning pays for itself by reducing operating costs and carbon footprint. Whether the data centre is new and underpopulated or density and heat loads are increasing, the...

Open the catalog to page 3
SmartCool™ 16-233kW Sales Brochure (English) - 4

Precise conditioning Intuitive climate control Sensitive computer equipment operates best within tight environmental tolerances, yet thermal loads in data centres are continually uctuating and many servers are under-utilised. Rather than wasting power by working at full load, the SmartCool™ anticipates and responds immediately to expected or unforeseen load variations, managing specic temperatures within ± 1°C accuracy. Balancing room temperature and humidity The balance between temperature and relative humidity is intrinsically linked. By precisely controlling temperature, the SmartCool™...

Open the catalog to page 4
SmartCool™ 16-233kW Sales Brochure (English) - 5

Air ow management The SmartCool™ delivers cold air through oor-mounted grilles directly to the front of the server racks. By presenting the right amount of air ow, at the correct temperature to the server inlet, the SmartCool™ ensures optimum air ow management and eliminates hot spots. Typically a 50% drop in air volume results in an 83% reduction in fan power input SmartCool™ 60 – 233kW CW models Ideal for large data centre applications, these models offer up to 10% more cooling/m2 for the same footprint*. The air ow design with large slab coil and fans located in the base of the unit give...

Open the catalog to page 5
SmartCool™ 16-233kW Sales Brochure (English) - 6

Intelligent controls Seamlessly managing your system CONTROLS The control centre of each of our cooling systems is a sophisticated electronic microprocessor with control logic specially developed by Airedale. As an intelligent stand-alone unit or when networked with up to eight units, the SmartCool™ adapts to your data centre’s particular requirements. Its compact, modular design makes it easy for multiple units of different size and capacity to be added as load increases or to eliminate hot spots. Smartly networked standby units ensure 24/7 availability. The microprocessor uses sensors to...

Open the catalog to page 6
SmartCool™ 16-233kW Sales Brochure (English) - 7

Building management Taken to another level ACIS™ building management system developed by Airedale, enables you to manage smart cooling and other building services, from any manufacturer, in a single, integrated system across multiple sites and communication protocols. ACIS™ sits at the front end of a building system, putting you in control of reducing operating costs. Generator/ UPS/Server Energy Manager Sequencer With the click of a button on a PC, tablet or phone, valuable and intelligent information can be pulled back automatically for remote 24/7 monitoring and maintenance; enhanced...

Open the catalog to page 7
SmartCool™ 16-233kW Sales Brochure (English) - 8

Flexible systems To t your specic operation Single circuit Single circuit The SmartCool™ X100/X200 is an air cooled, direct expansion (DX), single circuit system linked to a separate, remotely mounted air cooled condenser. Optimised for heat transfer using energy efcient refrigerant R410A in each circuit, the SmartCool™ system is located within the conditioned space, absorbing room heat and transferring it outside to the condenser. By using one or more same/dissimilar sized scroll compressors across the circuit, part load efciency can be maximised and capacity more precisely matched to...

Open the catalog to page 8
SmartCool™ 16-233kW Sales Brochure (English) - 9

DUAL COOL Airedale condenser Dual cool Dual circuit DX air cooled and chilled water (X2C0) For redundancy in critical applications, the SmartCool™ dual cool X2C0 offers two different cooling mediums, air cooled DX and chilled water, within the same case. The X2C0 system is managed by the AireTronix microprocessor to select which medium acts as the primary source of cooling or which acts as back-up, should the primary source fail or is unable to cope with the heat load. Suitable for applications favouring reduced refrigerant charges, the SmartCool™ W2W2 is a double circuit system featuring...

Open the catalog to page 9
SmartCool™ 16-233kW Sales Brochure (English) - 10

Specications at a glance SmartCool™: Optimising the key drivers in efcient building operation • Excellent part load performance from staged cooling • Minimum space claim • Low sound minimised by scroll compressors and optimised setpoint management particularly during part load • Resilience ensuring 24/7 availability • Fans and all main components accessible from front for easy access / maintenance • Precongured, packaged units with optional, colour touch screen microprocessor display for seamless ne-tuning • Fits through a standard door (16 – 150kW) units • Free-cooling dual cool variant...

Open the catalog to page 10
SmartCool™ 16-233kW Sales Brochure (English) - 11

Air cooled (R410A) / Water cooled (R410A) Chilled water Compressors per circuit Inverter compressor No option Air cooled (R410A) / Water cooled (R410A) Free-cooling / Chilled water Compressors per circuit Inverter compressor Decimetre case width (dm) SmartCool / SmartCool long coil Nomenclature explained SC/SL/SN/SR/SD Mono / Dual Mono / Dual Case size Electrical & Controls • Advanced AireTronix controls technology managing and optimising the system’s performance Optional • ACIS™ building management integrates cooling and other building services, improves data and reduces operating costs •...

Open the catalog to page 11

All Airedale International Air Conditioning catalogs and technical brochures

  1. InRak™

    8 Pages

  2. OnRak™

    12 Pages

  3. Ecotel™

    12 Pages

  4. EasiCool™

    12 Pages

  5. SmartCool™CW

    16 Pages

  6. InRak™

    8 Pages

  7. AireWall™

    2 Pages

  8. Product guide

    20 Pages

Archived catalogs

  1. AireTile™

    4 Pages