Catalog excerpts
Product Guide BRITISH MANUFACTURER ENERGY EFFICIENCY
Open the catalog to page 1Quick reference Find the right solution for your application Six product ranges supported by an extensive number of alone, but when integrated, they share intelligence and further models and exceptional conguration exibility means that reduce energy through combined efciencies. when selecting an Airedale system, your choice of variants is Our breadth of expertise enables us to engineer innovative, considerable, enabling you to precisely match your application. integrated cooling solutions across commercial and public We apply the latest technology led by smart control logic to sectors - in...
Open the catalog to page 2Total support, whenever you need it Ultima™ Compact 30 - 450kW Ult. Compact FreeCool 75 - 450kW FREE Complete control of your site • Intelligent component optimisation Ultima™ Remote Air Cooled & Ultima™ Water Cooled 75 - 450kW • Energy analysis and monitoring • ACIS™ building management system • Chiller sequencing, networking, integration • Remote monitoring across sites • Control/component/switchgear upgrades HEAT PUMP FREE COOL • Flexible service and maintenance plans; F Gas compliance • On call engineers for immediate response • Energy saving upgrades PAGE 10 • Flat pack solutions/unit...
Open the catalog to page 346% energy saving in free-cooling dual cool variant Up to 88% saving in power input with hot gas re-heat option + DX air cooled (16 - 140kW); water cooled (50 127kW); chilled water (11 - 233kW) and freecooling models; single and dual circuits + Up to 6 stages of tandem scroll compressor DX cooling 50 - 100% variable capacity control with suction throttle valve option Up to 70% more efciency with EC fans optional upgrade on all indoor and outdoor units + 76 DX (38 air cooled and 38 water cooled) and 34 chilled water models, in 6 case sizes + Tandem scroll compressors for reduced sound and...
Open the catalog to page 4Up to 30% increase in system efciency with optional electronic expansion valves + DX, chilled water and glycol free-cooling systems + 102 models in 5 case sizes + AV mounted fans + Direct drive, speed controllable fans (models 9 19kW) + Reduced sound and vibration emission levels + Single, dual and triple circuit systems for stage cooling control + Variable humidication for precisely conditioned air FREE COOL + G4 as standard lter; optional G3/F6 for higher efciency ltration Ecotel™ 5 - 19kW FREE COOL AIR Up to 70% energy saving with free-cooling mode + Energy efcient outdoor cabin cooler +...
Open the catalog to page 5OnRak™ 3 - 35kW 88% saving in power input an OnRak™ with EC fan and an EER of 144.7 n+1 fan conguration for increased efciency and resilience Over 50% saving in energy when integrated with a free-cooling chiller + Efcient rear door heat exchanger with 200mm footprint + Two congurations: (n) 35kW cooling (100% air volume); optional (n+1) 30kW cooling (75% air volume) + Designed to t 42 - 47U racks + Supplied with integrated rack or adapted to t a customer specic rack, with simple connections + Pressure differential management - maintaining pressure in the rear of the rack within the server...
Open the catalog to page 6ECHO High efciency IT cooling system 67% energy saving compared with a conventional downow system 50% less air volume, using less power EC Up to 95% free-cooling per annum + Ensures the correct air quantity, temperature and pressure is fed to the server inlet + Variable rack load densities to a maximum of 20kW per rack + No chilled water/refrigerant connections at the rack or in the IT space + Control is led from rack level, rescheduling the Airedale ECHO CRAC and free-cooling chiller to optimise performance Dynamic fan oor tile Boosts cooling efciency via active air distribution Four model...
Open the catalog to page 7A highly versatile range of air handling units, including R410A, free-cooling and indirect adiabatic cooling systems, maximising efciency and minimising operational costs for data centre, retail and commercial environments. FREE COOL Indirect adiabatic AHU No potential contaminants enter the data centre Optimised for supply air temperature of 26°C / 27°C + Two model congurations, roof or wall mounted; 100kW 4.1m x 5m x 2.3m (h x l x w) and 150kW 4.1m x 5m x 3.4m (h x l x w) – units can be matched to 300kW + Integrated inlet for fresh air for room pressurisation and air quality (F7...
Open the catalog to page 8Up to 70% more efciency with EC fans 0 - 100% free-cooling as standard using full design air volume Smaller models t the space of a standard ceiling tile measuring 600mm2 + 11 models for exibility in heating, cooling and air ow FREE COOL + Available in 2 pipe and 4 pipe congurations + Cooling and heat pump variants + Efcient AC backward curved fan technology + 57 - 75kW heating capacity with reverse cycle (dual circuit heat pump variant only) HEAT PUMP + ETL listed* (models featuring an inverter-driven condenser fan and return air fan) + Packaged or split modules (evaporator / condenser) +...
Open the catalog to page 9Chillers Scroll DeltaChill™ (DCC) 110 - 1010kW TurboChill™ (TCC) 200 - 1775kW DeltaChill™ FreeCool (DCF) 140 - 1080kW TurboChill™ FreeCool (TCF) 200 - 1830kW ESEER up to 5.03 with EC fan option MICRO FREE COOL OPTIONS + Up to 95% free-cooling with DCF + Up to 38% more cooling/m2 than Airedale’s previous generation free-cooling chillers + Low sound ranges: Quiet and Extra Quiet + E-coated micro-channel coils reduce life cycle costs and footprint (all DCF models and DCC 450 - 960kW) + Modular, efcient ‘V’ frame fan coil module + Direct Effect Life Cycle (DELC) CO2 equivalent emissions of...
Open the catalog to page 10OptiChill™ (OPC) 500 - 1140kW OptiChill™ FreeCool (OFC) 750 - 1330kW ESEER up to 4.21 with OPC, for optimum operating efciency Up to 30% increase in system efciency with electronic expansion valves (option) FREE COOL + ETL listed* (all OPC models) + 52 models (OPC) and over 200 models (OFC) + Quiet and Extra Quiet ranges + Dual independent refrigeration circuits for resilience + Up to 95% free-cooling with OFC + 12.5°C increase in operational evaporating temperature range allowing supply water temperatures to be increased, thus raising the freecooling threshold and giving enhanced...
Open the catalog to page 11All Airedale International Air Conditioning catalogs and technical brochures
-
TurboChill-Hydro-Brochure
12 Pages
-
InRak™
8 Pages
-
SmartCool™ i-drive Inverter
12 Pages
-
TurboChill™ Water Cooled
8 Pages
-
Condensing Unit
16 Pages
-
Ultima Compact Chiller
8 Pages
-
OnRak™
12 Pages
-
Ecotel™
12 Pages
-
EasiCool™
12 Pages
-
SmartCool™CW
16 Pages
-
TurboChill™ -en
8 Pages
-
DeltaChill R32
2 Pages
-
InRak™
8 Pages
-
AireWall™
2 Pages
-
Precision Air Conditioning CW
16 Pages
Archived catalogs
-
AireTile™
4 Pages