OnRak™ 3kW-35kW Sales Brochure (English)

OnRak™ 3kW-35kW Sales Brochure (English)
1 / 12 PagesView full catalog

OnRak™ 3kW-35kW Sales Brochure (English)

Product catalog summary
Overview: The document provides a comprehensive overview of the OnRak™ rear door heat exchanger, emphasizing its role in enhancing cooling efficiency in data centers. Key features include its energy efficiency, adaptability, and seamless integration with free-cooling chillers.
Specifications: The OnRak™ delivers up to 35kW of cooling capacity while adding only 200mm to rack depth. It incorporates EC axial fans for superior performance and energy savings, achieving an Energy Efficiency Ratio (EER) of up to 183.0 in n+1 configurations.
Energy Efficiency: The system can reduce power consumption by up to 88% compared to traditional CRAC units. When paired with a free-cooling chiller, it can achieve up to 50% energy savings, thereby lowering operating costs and carbon emissions.
Design and Flexibility: The OnRak™ is engineered to handle high discharge temperatures from servers, making it suitable for medium to high-density environments. It is adaptable to various rack sizes and features hot-swappable fans for uninterrupted operation.
Integration and Control: The system integrates with Airedale's free-cooling chillers and is managed by a sophisticated microprocessor, allowing for intelligent control of cooling duties, temperature, airflow, and pressure to optimize performance.
Case Study: At the University of Leeds, the OnRak™ effectively cooled high-density racks, offering a flexible solution that integrates with existing cooling loops and conserves space.
Testing and Quality Assurance: Airedale conducts rigorous testing in dedicated facilities to ensure quality, simulating various load conditions to verify performance and energy efficiency.
Introduction: The document also highlights Airedale's cooling systems and services, including customer testimonials, training opportunities, and support services.
Customer Testimonials: Testimonials from Yorkshire Building Society, EMIS, and the National Gallery commend Airedale's energy-saving solutions, reliable service, and UK-based support.
Training and Development: Airedale offers industry-recognized air conditioning and refrigeration courses, providing hands-on experience with advanced systems.
Support Services: Comprehensive aftersales support includes a 24/7 emergency helpline, remote monitoring, chiller sequencing, and live demonstrations.
Service Plans: Service plans offer preventative maintenance to enhance system efficiency, reduce energy costs, and ensure F Gas compliance, with a full parts and labor warranty for the first 12 months.
Contact Information: Airedale International Air Conditioning Limited, Leeds, England. Phone: +44 (0)113 239 1000, Email: [email protected]
Certifications: Airedale holds ISO 14001 and ISO 9001 certifications, ensuring adherence to quality and environmental management standards.
See more

Catalog excerpts

OnRak™ 3kW-35kW Sales Brochure (English)-1

Rear door Up to 35kW + EER up to 114.5 + Up to 88% less power input + Up to 50% saving in energy* * when integrated with a free-cooling chiller CHILLED WATER www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY

 Open the catalog to page 1
OnRak™ 3kW-35kW Sales Brochure (English)-2

Cooling hot spots Flexibly, where it matters The OnRak™ is a resilient rear door heat exchanger, designed to manage high discharge temperatures directly from the server into the aisle space. In dealing with the heat load closer to the source, the OnRak™ is highly efcient in both power usage and oor space, and is ideal for targeting hot spots in medium to high density environments. The OnRak™ has a slim conguration which adds only 200mm to the depth of the rack, reducing the cooling space claim whilst providing up to 35kW of cooling. The OnRak™ offers an expandable, adaptable chilled water cooling...

 Open the catalog to page 2
OnRak™ 3kW-35kW Sales Brochure (English)-3

OnRak™ with EC fan compared with a conventional CW CRAC unit* 12,000 10,000 The OnRak™ has been engineered with very low air ow resistance and accommodates latest EC axial fan technology. This enables it to modulate fan speed in response to load uctuations and offer greatly enhanced fan efciency particularly at part load. Power consumption / year (kW/h) OnRak™ with EC fan 88% power saving Saving in power consumption: 88% annual power saving Conventional CW CRAC unit EER 17.0 * Both units running in same application and delivering same amount of cooling performance Reducing operating costs and...

 Open the catalog to page 3
OnRak™ 3kW-35kW Sales Brochure (English)-4

in high density areas In high density areas of over 20kW heat load per rack, hot spots abound and space is at a premium. Adding only 200mm to the depth of the server rack, the OnRak™ is perfect for dealing with hot spots. Temperature (C) The variable speed fans within the OnRak™ door respond seamlessly to load uctuations, pulling hot air directly from the server cabinet across the door’s high efciency heat exchangers. The compact hot aisle is therefore contained between the rack and the OnRak™, which means that the entire data centre is at server inlet temperature creating a more comfortable...

 Open the catalog to page 4
OnRak™ 3kW-35kW Sales Brochure (English)-5

Using heat to increase free-cooling The OnRak™ delivers even greater efciency when integrated with one or more Airedale free-cooling chillers. Free-cooling saves vast amounts of energy, particularly when room temperatures are high. For free-cooling to operate, the temperature difference between the ambient air and hot return water can be as little as 1°C. Concurrent free-cooling Airedale chillers offer concurrent free-cooling which is active whenever the ambient temperature is below the return water temperature.The system controls constantly monitor the temperature differences and will only switch...

 Open the catalog to page 5
OnRak™ 3kW-35kW Sales Brochure (English)-6

Intelligent controls Seamlessly managing your system The control centre of each of our cooling systems is a sophisticated electronic microprocessor with control logic specially developed by Airedale. The microprocessor uses sensors to send and receive messages to and from active components such as compressors, fans and pumps so they interact with each other, balancing cooling duty, temperature, air ow and pressure to exactly match the application. Resilience is designed into OnRak™ units from day one and is managed by advanced controls logic to maintain cooling and give you complete condence...

 Open the catalog to page 6
OnRak™ 3kW-35kW Sales Brochure (English)-7

Data centre management Taken to another level ACIS™ building management system developed by Airedale, enables you to manage smart cooling and other building services, from any manufacturer, in a single, integrated system across multiple sites and communication protocols. ACIS™ sits at the front end of a building system, putting you in control of reducing operating costs. Generator/ UPS/Server Energy Manager Sequencer With the click of a button on a PC, tablet or phone, valuable and intelligent information can be pulled back automatically for remote 24/7 monitoring and maintenance, enhanced system...

 Open the catalog to page 7
OnRak™ 3kW-35kW Sales Brochure (English)-8

Specications at a glance Simple connections to customer-specic rack To apply the OnRak™ to a customer-specic rack with a different width and /or U size, the OnRak™ can be supplied with an appropriate mating frame which is tted to the rack cabinet. The OnRak™ door is then simply dropped onto the frame via lift-off hinges. Power supply Two exible, stainless steel braided hoses connect the coil to the chilled water supply. The exibility of the hoses allows the OnRak™ door to be easily opened for accessing hardware within the server cabinet, without the need to disconnect services or disrupt cooling....

 Open the catalog to page 8
OnRak™ 3kW-35kW Sales Brochure (English)-9

OnRak™ standard door size Nominal cooling capacity in kW Chilled water cooling Case width in centimetres LogiCool OnRak OnRak™ technical specications: Model no. 1) Nominal cooling capacity based on 14 / 20ºC water and 46ºC air on temperature Performance data calculated in accordance with BSEN 14511-2011 and Eurovent 6/6 OnRak™ in action University of Leeds data centre The challenge Higher densities in the high performance computing (HPC) facility of the University of Leeds have created an extra 30kW of load per 42U rack, which could not be cooled by conventional CRAC units since this would involve...

 Open the catalog to page 9
OnRak™ 3kW-35kW Sales Brochure (English)-10

Performance tested And proven Quality is assured by our on-site, worldclass testing and production facilities and the application of the latest manufacturing techniques and continuous improvement. Airedale’s dedicated test facility is the only purpose-built one of its kind in the UK. Here all our product lines are performance tested for a global market. Accurate test data is produced anywhere from -5°C to +55°C in controlled ambient environments. The climate test chambers include a hemi-anechoic chamber for accurate measurement of product sound data. A factor inuencing selection of Airedale was...

 Open the catalog to page 10
OnRak™ 3kW-35kW Sales Brochure (English)-11

Total support Whenever you need it At Airedale, we don’t just manufacture and supply cooling and refrigeration products; we also provide a broad range of supporting services to ensure our customers receive the best possible aftersales care. With more than 40 years’ experience in business critical cooling, investing in an Airedale cooling or refrigeration solution means that you can benet from our advice, expertise and technical support too. From design and selection, through to commissioning and beyond, we make sure your system reduces your total cost of ownership, whilst providing maximum availability...

 Open the catalog to page 11

All Airedale International Air Conditioning catalogs and technical brochures

  1. InRak™

    8  Pages

  2. Condensing Unit

    16  Pages

  3. OnRak™

    12  Pages

  4. Ecotel™

    12  Pages

  5. EasiCool™

    12  Pages

  6. SmartCool™CW

    16  Pages

  7. InRak™

    8  Pages

  8. AireWall™

    2  Pages

  9. Product guide

    20  Pages

Archived catalogs

  1. AireTile™

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.