“Data Centre Cooling Product of the Year” Indirect adiabatic cooling for resilient, optimised data centre cooling g + Delivers all year round free-cooling* + Zero air mixing ensures no contaminants enter your data centre + No requirement for internal CRAC units maximises your IT footprint + Adiabatic system with full UV sterilisation *Based on 26°C supply temperature and above and a London ambient prole COOL FREE-COOLING CHILLED WATER INVERTER COMPRESSOR www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY
Open the catalog to page 1Next generation data centre cooling Unparalleled efciency Available in ve footprints between 100kW and 440kW, with either wall or roof optimised connections, the AireFlow™ is a versatile free cooling and indirect adiabatic air handling unit (AHU), designed to make your data centre more productive and efcient. Reduced operating costs & carbon footprint By selecting the AireFlow™ you are investing in an AHU that will signicantly reduce your running costs and carbon footprint. The AireFlow™ is congured to optimise free-cooling potential even in high ambient temperatures. Using fresh air as the...
Open the catalog to page 2Based on London, UK ambient temperatures, systems can achieve 100% free-cooling year round (operating inside the ASHRAE recommended X axis: DRY BULB TEMPERATURE (°C) N + 1 fan configuration enhanced by smart control logic and EC fan technology, give the AireFlow™ built-in redundancy and excellent part load efficiencies
Open the catalog to page 3Resilient, powerful indirect adiabatic cooling For your data centre Wetted media versus spray systems – the benets Reduced risk of corrosion With the wetted media system, water is contained within the media and stainless steel drip tray itself, inherently resulting in a reduced risk of corrosion. Conversely, with a spray system, water coats all internal metal work in the adiabatic section, increasing the risk of corrosion damage. 37.5% less water storage required – 6m3 versus 9.6m3
Open the catalog to page 4Less water consumption The AireFlow™ consumes just 0.25m³ of water per hour whereas typically a spray system will use up to 0.40m³ of water per hour at peak UK ambient temperatures. Typical water consumption for a 1MW data centre in London A sterile environment The AireFlow™ unit is designed to ensure a sterile environment. Circulating water is constantly passed through a UV system to sterilise it and kill any bacteria and the self-cleaning adiabatic system automatically drains itself periodically. would be 600m³ per annum.* * Based on a datacentre with N+1 redundancy, operating with a 12K...
Open the catalog to page 5Brilliantly engineered For increased reliability High efciency air-toair aluminium plate heat exchanger A robust construction of aluminium with an epoxy coating ensures signicantly increased thermal conductivity, over plastic or composites, along with protecting against corrosion and high relative humidity on the ambient side. Designed for airows from 3m3/s up to 21m3/s, its sealed and alternate air paths prevent mixing, and gives a large heat exchange surface area for increased cooling capacity. Wetted media adiabatic system N+1 fan conguration for increased efciency and uptime The wetted...
Open the catalog to page 6Adaptive energy efcient operation Three distinctive operating modes Free Cooling – 0˚C – 15˚C Dry bulb temperature At low ambient temperatures the AireFlow™ can achieve 100% free cooling. The heat exchanger requires less ambient airow to deliver the cooling capacity, resulting in a lower power input. Adiabatic Free Cooling – 15˚C – 35˚C Dry bulb temperature (Max wet bulb approx. 24˚C) As the ambient temperature begins to increase, the heat exchanger requires more airow to deliver the required cooling, the ambient fans ramp up accordingly. Top up Operation (Concurrent Mechanical & Free...
Open the catalog to page 7AireFlow™ - standard case sizes *A = 2300mm (165kW), A = 3400mm (220kW) The AireFlow™ is available in two case sizes, suitable for both roof or wall mounted connections, and units can be positioned next to each other, by having a left and right handed unit respectively giving a space claim reduction. Mechanical • Available in ve footprints between 100kW and 440kW, with either wall or roof optimised connections • Two case sizes (H x L x W) 165kW – 4.1m x 5.0m x 2.3m, (H x L x W) 220kW – 4.1m x 5.0m x 3.4m • Painted galvanised steel casing for corrosion protection • Adiabatic wetted media...
Open the catalog to page 8Nominal capacities Range Nomenclature Nominal capacities are based upon the Nomenclature explained following conditions and delivering 100% free-cooling: 23.4°C (Extreme max. Gatwick Airport) None / Top-up / Back-up Not Present / Present Left / Right AireFlow™ - technical specications: Aireow Conguration Cooling Density (kW/m²) Nominal capacity is given at 39°C return air temperature, 27°C supply air temperature, and 33.7°C DB/23.4° WB ambient temperature. • Zero air mixing ensures no contaminants enter your data centre • 400V / 3Ph / 50Hz single power supply • Mains isolator switch •...
Open the catalog to page 9Intelligent controls Seamlessly managing your system The control centre of each of our cooling systems is a sophisticated electronic microprocessor specially developed by Airedale. The intelligent microprocessor uses sensors which allow active components to interact. By interacting and sequencing components, the Generator/ UPS/Server Energy Manager controller manages and optimises the system’s performance, availability and power draw, giving the operator complete Building lighting system control. Fully-programmable via the control panel’s user-friendly display, the microprocessor can be...
Open the catalog to page 10Total support Whenever you need it At Airedale, we don’t just manufacture and supply cooling and refrigeration products; we also provide a broad range of supporting services to ensure our customers receive the best possible aftersales care. With more than 40 years’ experience in business critical cooling, investing in an Service plans An Airedale service plan provides a planned, Maximising your system’s effectiveness 24/7 optimum efciency of your system, enabling the user preventative maintenance package to sustain the to see real savings in energy costs and reduced carbon emissions. With...
Open the catalog to page 11All Airedale International Air Conditioning catalogs and technical brochures
-
TurboChill-Hydro-Brochure
12 Pages
-
InRak™
8 Pages
-
SmartCool™ i-drive Inverter
12 Pages
-
TurboChill™ Water Cooled
8 Pages
-
Condensing Unit
16 Pages
-
Ultima Compact Chiller
8 Pages
-
OnRak™
12 Pages
-
Ecotel™
12 Pages
-
EasiCool™
12 Pages
-
SmartCool™CW
16 Pages
-
TurboChill™ -en
8 Pages
-
DeltaChill R32
2 Pages
-
InRak™
8 Pages
-
AireWall™
2 Pages
-
Precision Air Conditioning CW
16 Pages
-
Product guide
20 Pages
Archived catalogs
-
AireTile™
4 Pages