WRL 026 -161
1 / 5Pages

Catalog excerpts

WRL 026 -161 - 1

Water cooled heat pump reversible water side Cooling capacity 6,6 ÷ 44,2 kW Heating capacity 7,5 ÷ 48,0 kW • High efficiency • Suitable for geothermal applications Version with Integrated hydronic kit Water-water offering chilled/hot water, designed to mit air conditioning needs in residential/commercial complexes or industrial applications. Indoor units with hermetic scroll compressors and plate heat exchangers. In the configuration with desuperheater, it is also possible to produce free-hot water. The technological choices made, always oriented to the highest quality, ensure very easy installation. In fact the electrical and hydraulic connections are all located in the upper part of the unit, facilitating the installation and maintenance operations and also reducing the technical gaps and their position in as little space as possible. ° Without storage tank A With storage tank FEATURES Operating field Full-load operation with the production of chilled water 4-18°C, and the possibility to produce also negative temperature water down to -8°C for the evaporator and hot water for the condenser up to 55 °C. (for more information, refer to the technical documentation). All the units are equipped with scroll compressors and plate heat exchangers; the base and panelling are made of steel treated with RAL 9003 polyester paints. The electric and hydraulic connections are all located on the upper part of the unit facilitating installation and maintenance. This allows reduced plant room space and installation in the smallest space possible. The heat pump can be supplied with all the components required for its installation in new systems and to replace other heat generators. It can be combined with low temperature emission systems such as floor heating or fan coils, but also with conventional radiators. The standard unit is supplied with a water filter, differential pressure switch and safety valve already installed on the service and source side (and also on the recovery side, if present). To obtain a solution that offers economic savings and facilitates installation, these units can be configured with an integrated hydronic kit on both hydraulic sides (service and source). Low-head and high-head pumps are available, along with a modulating 2-way valve that can only be applied on the source side to reduce consumption in applications with groundwater. MODUCONTROL CONTROL The command panel of the unit allows the rapid setting of the working parameters of the machine, and their visualisation. The display consists of 4 figures and various LEDs for indicating the type of operational mode, the visualisation of the parameters set and of any alarms triggered. The card stores all the default settings and any modifications. The regulation using an outside air temperature sensor (accessory) allows a dynamic control of the water temperature produced by increasing the energy efficiency of the system. AERSET: It makes it possible to automatically compensate for the operation setting of the unit to which it is connected, based on a 0-10V MODBUS input signal. Mandatory accessory MODU-485BL. KSAE: External air sensor. MODU-485BL: RS-485 interface for supervision systems with MODBUS protocol. PR3: Simplified remote panel. This makes it possible to carry out the unit's basic controls with the signalling of alarms. Can be made remote with shielded cable up to 150 m. VT: Anti-vibration supports. VPL: Pressure switch valve complete with connections, piloted directly in relation to condensation pressure; the valve modulates the volume of water needed to cool the condenser, thereby maintaining the condensation temperature unchanged.

Open the catalog to page 1
WRL 026 -161 - 2

ACCESSORIES COMPATIBILITY Model AERSET KSAE MODU-485BL PR3 Antivibration Integrated hydronic kit, Integrated hydronic kit, source side user side ° ° B,I,U,V N,P ° N,P B,I,U,V ° °,B,I,U,V °,N,P Integrated hydronic kit, source side ° U ° B,I,U,V B,I,V °,B,I,U,V Integrated hydronic kit, user side ° N,P N,P ° N,P °,N,P Pressure switch valve Ver °,A Description WRL Size 026, 031, 041, 051, 071, 081, 101, 141, 161 Operating field Standard mechanic thermostatic valve (1) Low temperature mechanic thermostatic valve (2) Model Heat pump reversible on the water side Version Without storage tank With...

Open the catalog to page 2
WRL 026 -161 - 3

PERFORMANCE SPECIFICATIONS WRL - ° Size Power supply: ° Cooling performance 12 °C / 7 °C (1) Cooling capacity Input power Cooling total input current EER Water flow rate source side Pressure drop source side Water flow rate system side Pressure drop system side Heating performance 40 °C / 45 °C (2) Heating capacity Input power Heating total input current COP Water flow rate source side Pressure drop source side Water flow rate system side Pressure drop system side Power supply: M Cooling performance 12 °C / 7 °C (1) Cooling capacity Input power Cooling total input current EER Water flow...

Open the catalog to page 3
WRL 026 -161 - 4

PERFORMANCE SPECIFICATIONS WRL ABP Size Power supply: ° Cooling performance 12 °C / 7 °C (1) Cooling capacity Input power Cooling total input current EER Water flow rate source side Useful head source side Water flow rate system side Useful head system side Heating performance 40 °C / 45 °C (2) Heating capacity Input power Heating total input current COP Water flow rate source side Useful head source side Water flow rate system side Useful head system side Power supply: M Cooling performance 12 °C / 7 °C (1) Cooling capacity Input power Cooling total input current EER Water flow rate source...

Open the catalog to page 4
WRL 026 -161 - 5

ELECTRIC DATA Size Electric data GENERAL TECHNICAL DATA Size Compressor Type Number Circuits Refrigerant Refrigerant charge Source side heat exchanger Type Number System side heat exchanger Type Number Source side hydraulic connections Connections (in/out) Sizes (in/out) System side hydraulic connections Connections (in/out) Sizes (in/out) Sound data calculated in cooling mode (1) Sound power level Sound pressure level (10 m) (1) Sound power calculated on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure (cold...

Open the catalog to page 5

All AERMEC catalogs and technical brochures

  1. FCZI-D

    5 Pages

  2. FCZ-D

    5 Pages

  3. NRG

    9 Pages

  4. HWF

    4 Pages

  5. WFGI

    9 Pages

  6. WFGN

    7 Pages

  7. WFI

    9 Pages

  8. WFN

    8 Pages

  9. BHP

    6 Pages

  10. DUALJET

    10 Pages

  11. ANK

    8 Pages

  12. ANLI

    8 Pages

  13. MGW

    2 Pages

  14. NSI

    4 Pages

  15. TA

    4 Pages

  16. TS

    2 Pages

  17. MHM

    4 Pages

  18. MHW

    2 Pages

  19. All product

    404 Pages

Archived catalogs