Split System^
Open the catalog to page 1The Aermec philosophy A complete range, capable of resolving every air conditioning problem: this is Aermec for room conditioners. Completeness not only for models but with options and possibilities: cooling only andheat pump versions; environmentally friendly refrigerants; advanced technology, such as inverters which allow optimisation of performance in relation to temperature setpoints at all times and to obtain significant energy savings; installation versatility, to solve every space problem in the best way. Aermec is a business leader in the Italian and European air conditioning market....
Open the catalog to page 2Split System and VRF system Guide This document offers and overall view of the Aermec range for residential and commercial applications. It contains a large variety of internal unit types with wall, floor, ceiling and ducted units, available in heat pump versions both with on/off and inverter technology. This split system and VRF system guide replaces all previous editions. For more detailed information please refer to the individual product technical and commercial documentation available on our website www.aermec.com. Aermec head office – Bevilacqua (VR) - Italy
Open the catalog to page 3Summary Green Line Monosplit Inverter Wall mounted: SI, HWI . . . . . . . . . . . . . . . . . . . . . . pag. 9, Ducted: LCI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. pag. Cassette: LCI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. Floor/Ceiling mounted: LCI . . . . . . . . . . . . . . . . . . . . . . . pag. Monosplit On/Off Ducted: DXE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 14 Multisplit Inverter MKM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 16 Green Line - VRF Systems MDW . . ....
Open the catalog to page 5Green Line Inverter, greater comfort, lower consumption Today offers electronic technology applied to air conditioning. It is system controlled by “Fuzzy” logic, capable of maintaining the ideal comfort conditions in the space by operating the air conditioner at variable “speed” and capacity, without the continuous stops and starts from traditional units: maximum speed and power when required, gradual and automatic reduction to constantly adapt to the ambient conditions without fluctuations. This means improved comfort obtained by the absence of temperature fluctuations and a significant seasonal...
Open the catalog to page 8Split system air conditioner and heat pump Wall mounted monosplit DC Inverter Technology and air ioniser standard R410A Regulation (EU) N. 206/2012 Delegated Regulation (EU) N. 626/2011 Features •Available in 4 different capacity sizes. •Refrigerant R410A •Heat pump operation with reversible refrigerant cycle and defrost control •Tangential type fan with 4 speeds: - 3 speeds directly selected (Minimum, Medium, Maximum) - One Super High speed when the Rapid Cooling/ Heating (TURBO) function is activated, to achieve the required temperature as quickly as possible •DC Inverter rotary compressor...
Open the catalog to page 9Green Line Split system air conditioner and heat pump Wall mounted monosplit with DC Inverter Technology and air ioniser standard R410A NEW N! DESIG Regulation (EU) N. 206/2012 Delegated Regulation (EU) N. 626/2011 •Available in 4 different capacity sizes •Refrigerant R410A •Heat pump operation with reversible refrigerant cycle and defrost control •Tangential type fan with 4 speeds: - 3 speeds directly selected (Minimum, Medium, Maximum) - One Super High speed when the Rapid Cooling/ Heating (TURBO) function is activated, to achieve the required temperature as quickly as possible •DC Inverter...
Open the catalog to page 10Monosplit air conditioner and heat pump split system DC Inverter Technology R410A LCI_D Regulation (EU) N. 206/2012 Delegated Regulation (EU) N. 626/2011 Features The LCI series consist of an external Inverter unit connected to 3 types of internal units External unit: • LCI: 8 sizes of different capacity with single phase power • LCI_T: 4 sizes of different capacity with three phase power Internal unit: • Cassette (False ceiling mounted) (600x600): LCI036CS - 051CS (It is required to connect with accessory LCIGL40S) • Cassette (False ceiling mounted) (840x840): LCI071C - 086C - 101C -121C (It...
Open the catalog to page 11Green Line Monosplit air conditioner and heat pump split system DC Inverter Technology Technical data Outdoor Unit (U.E.) LCI Indoor Unit (U.I.) LCI Cooling capacity Total power input SEER Energy efficiency class in cooling* Heating capacity Total power input SCOP Energy efficiency class in heating* Ø liquido inch Refrigerant connections Ø gas inch *Seasonal Energy Efficiency. See technical data Outdoor Unit (U.E.) LCI Indoor Unit (U.I.) LCI Cooling capacity Total power input SEER Energy efficiency class in cooling* W Heating capacity Total power input SCOP Energy efficiency class in heating*...
Open the catalog to page 12Dimensional Data - Outdoor Unit Outdoor Unit Mod. Width Height Depth Weight Dimensional Data - Indoor Unit Cassette Mod. Width Height Depth Weight Height Width Depth Weight Height Width Depth Weight Compatibility Mandatory Accessories for Indoor Unit Cassette - Grid Dimensions grid (mm) Dimensions Cassette Indoor units (mm) 600 x 600
Open the catalog to page 13Green Line Air cooled heat pump unit in two sections. Horizontal ducted installation Features •Available in 4 sizes •Manufactured with refrigerant R410A •Heat pump versions •Auto-Restart (function can be disabled) •Condensation control device as standard for operation in cooling down to -15°C external air temperatureserie. Internal Unit (DXE E): •Ducted unit for horizontal installation •Units supplied with two air sensors: one on the wired control panel and one on the internal unit air intake. Selected from the wired control panel •Metal casing in galvanised sheet steel •Double inlet centrifugal...
Open the catalog to page 14Technical Data Outdoor Unit Indoor Unit Cooling capacity Total power input cooling mode Heating capacity Total power input heating mode nominale nominale nominale nominale Ø (gas) Ø (liquido) Refrigerant connections Dimensional Data (Indoor Unit) DXE (Indoor Unit) Height Width Depth Weight Dimensional Data (Outdoor Unit) Dimensional data DXE (outdoor unit) Height Width Depth Weight Maximum ove
Open the catalog to page 155 Pages
5 Pages
9 Pages
4 Pages
9 Pages
7 Pages
9 Pages
8 Pages
5 Pages
21 Pages
6 Pages
10 Pages
20 Pages
12 Pages
40 Pages
92 Pages
8 Pages
8 Pages
15 Pages
8 Pages
2 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
16 Pages
404 Pages
48 Pages
194 Pages
4 Pages
2 Pages
4 Pages
2 Pages