Product catalog summary
Overview: The document provides a comprehensive description of reversible outdoor heat pumps designed for residential, commercial, and industrial use. These units are constructed from galvanized steel with a polyester paint finish and are available in four versions: Standard, High Efficiency (A), Silenced High Efficiency (E), and Standard Silenced (L).
Features: The heat pumps operate efficiently in temperatures from -15°C to 49°C, producing hot water up to 60°C. They include dual-circuit systems for enhanced efficiency, use eco-friendly R32 refrigerant, and feature new condensing coils to reduce gas usage. An electronic expansion valve improves energy efficiency, particularly at partial loads. An optional integrated hydronic kit is available for cost savings and easier installation.
Control System: The PCO⁵ microprocessor control system features a 7" touch screen for easy navigation and parameter adjustment. It supports Master-Slave configuration, programmable timers, and integral proportional logic for temperature control. Additional features include floating HP control and Night Mode for improved efficiency and comfort.
Accessories: Available accessories include RS-485 and Ethernet interfaces, remote monitoring devices, flow switches, and anti-vibration supports. Factory-fitted options include devices for peak current reduction and power factor correction.
Configurator: The configurator section outlines customization options for the heat pumps, including size, operating field, model, heat recovery, version, coil materials, fan types, power supply, and integrated hydronic kits.
Specifications: The document details performance metrics such as SEPR (Seasonal Energy Performance Ratio) and efficiencies for different temperature applications (35°C and 55°C). It also includes electrical data, such as maximum and peak current values for sizes ranging from 0800 to 3600.
Technical Data: The compressors are scroll type with on-off regulation, using R32 refrigerant. The refrigerant load for different circuits is specified, with a global warming potential (GWP) of 675 kg CO2eq.
System Components: The heat exchangers are brazed plate type, and the fans are axial with asynchronous motors. Air flow rates and sound data, including sound power and pressure levels, are provided.
Dimensions and Weights: Dimensions and weights for different configurations, including those with integrated hydronic kits, are listed. The document specifies dimensions (A, B, C) and empty weights for each size.
Additional Information: Data is calculated without hydronic kits and accessories, and all information is subject to change without notice. Aermec reserves the right to make modifications as necessary.
See more

Catalog excerpts

NRG-1

Reversible air/water heat pump Cooling capacity 195,2 ÷ 639,6 kW Heating capacity 209,3 ÷ 674,2 kW • High efficiency also at partial loads • Reduced amount of refrigerant • Night mode Option integrated hydronic kit An optional, integrated hydronic kit containing the main hydraulic components, to obtain a solution that allows you to save money and to facilitate installation. It is available in different configurations with storage tank or with fixed pumps also inverter. CONTROL PCO⁵ Dual-circuit unit The units are dual-circuit, to ensure maximum efficiency both at full load and at partial load. The environmental impact of the units is reduced considerably owing to the last generation R32 refrigerant. Combining a reduced refrigerant load with a low global warming potential (GWP), these units boast low equivalent CO₂ values. ■ The leak detector is supplied as per standard. Use refrigerant fluid R32, whose classification according to ISO 817 is A2L (non-toxic, odourless and slightly flammable refrigerant). Working at full load up to -15 °C outside air temperature in winter, and up to 49 °C in summer. Hot water production up to 60 °C (for more details refer to the technical documentation). Operating field Microprocessor adjustment, with 7", touch screen keyboard, which allows to navigate intuitively among the various screens, allowing to modify the operating parameters and graphically view the progress of some variables in real time and the ad adjustment includes complete management of the alarms and their log. — Possibility to control two units in a Master-Slave configuration (from size 0800 to 2400) — The presence of a programmable timer allows functioning time periods and a possible second set-point to be set. — The temperature control takes place with the integral proportional logic, based on the water output temperature. — Floating HP control: available for all models with an inverter fan or DCPX. Thanks to continuous fan modulation, unit operation is optimised in every working position in cooling mode. The result is enhanced machine energy efficiency with partial loads. — "EASYLOG" data logger as per standard: allows all operating data read by the pCO5 to be stored on an SD card. — Night Mode: it is possible to set a silenced operation profile. Perfect for night operation since it guarantees greater acoustic comfort in the evenings, and a high efficiency in the time of greater load. The possibility to use electronic expansion valve, offers significant benefits, especially when the chiller is working with partial loads, increasing the energy seasonal efficiency of the unit. ° Standard A High efficiency E Silenced high efficiency L Standard silenced Electronic expansion valve Reversible outdoor heat pumps for the production of chilled/heated water designed to satisfy the needs of residential and commercial buildings, or for industrial applications. The base, the structure and the panels are made of galvanized steel treated with polyester paint RAL 9003. The whole range uses copper - aluminium condensation coils with reduced diameter rows, allowing a lower quantity of gas to be used compared to traditional coil

 Open the catalog to page 1
NRG-2

 — Low Superheat Control: Progressive superheating reduction in conditions of stability. This allows to increase energy performance: both in modulation and in full load conditions; — DLT control: Control of electronic valve at discharge temperature in certain operating conditions. This is demonstrated in an enhanced reliability of the control and a considerable expansion of the machine’s operating range, especially in heating mode. — AER485P1 — AERBACP — MULTICHILLER_EVO + AER485P1 In the 'J25-BMS2' port, the compatible accessories are: — AERNET — "BMS card" and "J25-BMS2" are two ports on the...

 Open the catalog to page 2
NRG-3

 Device for peak current reduction Ver °,A,E,L A grey background indicates the accessory must be assembled in the factory A grey background indicates the accessory must be assembled in the factory Power factor correction Ver °,A,E,L A grey background indicates the accessory must be assembled in the factory A grey background indicates the accessory must be assembled in the factory A grey background indicates the accessory must be assembled in the factory A grey background indicates the accessory must be assembled in the factory

 Open the catalog to page 3
NRG-4

(1) Water produced from 4 °C ÷ 20 °C (2) Water produced from 8 °C ÷ -10 °C (3) This option is not available with the Z operating field. The desuperheater must be intercepted in heating mode. In cooling mode, a water temperature no lower than 35°C must always be guaranteed on the heat exchanger inlet. (4) For all configurations including pump J please contact the factory. (5) Hydronic kit not available with sizes 0800 version °/L/A, 0900 version °, 1000 version °, 1800 version °. (6) For all possible configurations which include the “J” pump please be in touch with Aermec. Hydronic kit is not...

 Open the catalog to page 4
NRG-5

Size Cooling performance 12 °C / 7 °C (1) Cooling capacity Input power Cooling total input current EER Water flow rate system side Pressure drop system side Heating performance 40 °C / 45 °C (2) Heating capacity Input power Heating total input current COP Water flow rate system side Pressure drop system side (1) Data EN 14511:2022; Heat exchanger water (services side) 12°C / 7°C; outside air 35°C (2) Data EN 14511:2022; System side water heat exchanger 40 °C / 45 °C; Outside air 7 °C d.b. / 6 °C w.b. Size Cooling performance 12 °C / 7 °C (1) Cooling capacity Input power Cooling total input current...

 Open the catalog to page 5
NRG-6

Size Cooling performance 12 °C / 7 °C (1) Cooling capacity Input power Cooling total input current EER Water flow rate system side Pressure drop system side Heating performance 40 °C / 45 °C (2) Heating capacity Input power Heating total input current COP Water flow rate system side Pressure drop system side (1) Data EN 14511:2022; Heat exchanger water (services side) 12°C / 7°C; outside air 35°C (2) Data EN 14511:2022; System side water heat exchanger 40 °C / 45 °C; Outside air 7 °C d.b. / 6 °C w.b. Seasonal efficiency Size Fans: ° SEER - 12/7 (EN14825: 2018) (1) Calculation performed with FIXED...

 Open the catalog to page 6

All AERMEC catalogs and technical brochures

  1. FCZI-D

    5  Pages

  2. FCZ-D

    5  Pages

  3. HWF

    4  Pages

  4. WFGI

    9  Pages

  5. WFGN

    7  Pages

  6. WFI

    9  Pages

  7. WFN

    8  Pages

  8. WRL 026 -161

    5  Pages

  9. BHP

    6  Pages

  10. DUALJET

    10  Pages

  11. AERMEC FOR WINE

    20  Pages

  12. ANK

    8  Pages

  13. ANLI

    8  Pages

  14. MGW

    2  Pages

  15. NSI

    4  Pages

  16. TA

    4  Pages

  17. TS

    2  Pages

  18. Omnia Radiant

    4  Pages

  19. MHM

    4  Pages

  20. MHW

    2  Pages

  21. Technical Focus

    16  Pages

  22. All product

    404  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.