MHW - 1

DualSplit System Heat Pump Wall mounted with capacities from 5.5 to 7.2 kW Characteristics • External DualSplit unit MHW52C, MHW62C and MHW72C matched to 2 internal units. • Internal unit wall mounted type with remote control: MHW25E - MHW35E • Refrigerant R410A • Heat pump operation with refrigerant cycle reversing and defrost control • 4 speed tangential fan: - 3 selectable speeds (Minimum, Medium, Maximum) - Super high speed when operating the "Turbo" function to reach the desired temperature as quickly as possible • External unit with 2 rotary compressors • Extremely low noise operation • Microprocessor controller • Infra red remote control with back-lit liquid crystal display for controlling all functions • Emergency control capability if the batteries in the remote control are dead (AUTO key in the internal unit) • Liquid crystal front panel display showing operating mode and temperature (The display can be enabled and disabled from the remote control) • Clock in the remote control • Timer to programme operating hours (switching on and/or off) • Operating modes: Cooling, Heating, Dehumidication, Automatic and Only ventilation • Night comfort function (Sleep) • Energy saving function • Quick heating function (Turbo) • Quick cooling function (Turbo) • Personal climate function (I FEEL) which activates the internal sensor in the remote control allowing the user to have the desired climate around him • Extended ventilation programme (X-FAN) prevents the formation of mould within the internal unit • "Anti-freeze" function prevents the internal temperature from dropping below 8°C during the winter period • Intelligent pre-heat function to avoid blasts of cold air (Heating Mode) • Auto-diagnostic function • Auto-restart function after power failure • Defrost function of the external unit • External unit with connection for discharging the condensate • Washable air lter • Horizontally adjustable air discharge blades • Motorised deector blades operated from the remote control to adjust the discharge air vertically, with 8 xed positions or moving (Swing) • Refrigerant connections are type • Ease of installation and maintenance

Open the catalog to page 1
MHW - 2

Technical data External unit Internal unit Cooling capacity Power input Current input EER Energy efciency class Condensate output Heating capacity Power input Current input COP Energy efciency class Rated Power Input * Rated Current * Air ow (MHW_E) Sound pressure (MHW_E) dB(A) Sound pressure (MHW_C) Refrigerant connections Refrigerant pipes Ø liquid Ø gas mm (inch) Ø liquid mm (inch) Ø gas Power supply = 230V ~ 50Hz Sound pressure measured in a semi-anechoic chamber at 1m distance from the unit front * In accordance with EN-60335 standard Performance data in accordance with EN-14511...

Open the catalog to page 2

All AERMEC catalogs and technical brochures

  1. FCZI-D

    5 Pages

  2. FCZ-D

    5 Pages

  3. NRG

    9 Pages

  4. HWF

    4 Pages

  5. WFGI

    9 Pages

  6. WFGN

    7 Pages

  7. WFI

    9 Pages

  8. WFN

    8 Pages

  9. WRL 026 -161

    5 Pages

  10. BHP

    6 Pages

  11. DUALJET

    10 Pages

  12. ANK

    8 Pages

  13. ANLI

    8 Pages

  14. MGW

    2 Pages

  15. NSI

    4 Pages

  16. TA

    4 Pages

  17. TS

    2 Pages

  18. MHM

    4 Pages

  19. All product

    404 Pages

Archived catalogs