

Catalog excerpts

Dualsplit system heat pumps DualSplit System with capacities from 5 up to 7 kW Features • Dualsplit MGW52C, MGW62C and MGW72C outdoor units can be coupled with 2 indoor units. • Wall type indoor unit with remote control: MGW 025E - MGW 035E • R410A refrigerant gas • Heat pump functioning with reverse cooling cycle and defrost control • Indoor unit 4 speed tangential fan: Minimum, Medium, Maximum and Turbo • Outdoor unit with 2 rotary compressors • Silent functioning • Microprocessor control • Infrared ray remote control with liquid crystal display wired control panel for checking all functions • Possibility of emergency control (Auto/Stop key) • Liquid crystal display on front panel Timer for programming hourly functioning • Functioning mode: Cooling, Heating, Dehumidification, Automatic and Fan only • Self-diagnostics function • Air outlet louvered fins with horizontal adjustment facility • Powered deflector louvers for vertical adjustment of outlet air flow direction • Air filter with easy extraction and cleaning • Refrigerant lines with flared connections • Systems with multi-line refrigerant connections, where every indoor unit is connected tot he outdoor unit via dedicated refrigerant lines • Refrigerant lines up to 10 m for each individual indoor unit, maximum level distance between the indoor and outdoor unit 5m
Open the catalog to page 1
Technical data Outdoor unit Indoor unit Cooling capacity Total input power Total absorption EER Energy efcient class Total humidity removed Heating capacity Total input power Total absorption COP Energy efcient class Air ow rate (MGW E) Sound Pressure (MGW E) Sound Pressure (MGW C) Refrigerant connections Refrigerant lines Electric power supply = 230V~ 50Hz The performance refers to the following conditions: Sound pressure measures in a semianechoic chamber at 1m from the front Cooling: Room air temperature 27 °C D.B.; 19 °C W.B External air temperature 35 °C Maximum speed Refrigerant lines...
Open the catalog to page 2All AERMEC catalogs and technical brochures
-
FCZI-D
5 Pages
-
FCZ-D
5 Pages
-
NRG
9 Pages
-
HWF
4 Pages
-
WFGI
9 Pages
-
WFGN
7 Pages
-
WFI
9 Pages
-
WFN
8 Pages
-
WRL 026 -161
5 Pages
-
Aermec Company Profile
21 Pages
-
BHP
6 Pages
-
DUALJET
10 Pages
-
AERMEC FOR WINE
20 Pages
-
Aermec Data Centre solutions
12 Pages
-
Aermec Guida Idronica
40 Pages
-
Aermec Split System VRF
92 Pages
-
ANK
8 Pages
-
ANLI
8 Pages
-
Aermec Company Profile
15 Pages
-
Variable multi flow
8 Pages
-
NSI
4 Pages
-
TA
4 Pages
-
TS
2 Pages
-
Omnia Radiant
4 Pages
-
MHM
4 Pages
-
MHW
2 Pages
-
Technical Focus
16 Pages
-
All product
404 Pages
-
Split System and VRF systems
48 Pages
-
GPUY:products guide 2012
194 Pages
Archived catalogs
-
Data sheet - Fan coils
4 Pages
-
Data sheet - Dehumidifier
2 Pages
-
Data sheet - UR
4 Pages
-
Data sheet- split system
2 Pages