Description: The document describes internal installation units designed for providing chilled or hot water for air conditioning in residential, commercial, or industrial applications. These units are compact, flexible, and align with the requested load through an accurate control algorithm. They are constructed from galvanized steel with polyester paint.
Versions: The units are available in standard and high-efficiency versions.
Features: The units can produce chilled water down to -8°C and operate in heat pump mode with condenser water temperatures up to 60°C. They feature dual refrigerant circuits for efficiency and continuity, screw compressors, shell and tube heat exchangers, and electronic expansion valves for improved energy efficiency.
Control: The units use a pCO5 control type with a microprocessor, keyboard, and LCD display. They support Master-Slave configuration and have a programmable timer for setting operation periods and temperature control.
Accessories: Available accessories include RS-485 interface, remote monitoring via AERNET, MULTICHILLER_EVO for managing multiple units, remote control (PRV3), and anti-vibration supports (AVX). Factory-fitted accessories include power factor correction (RIF), condenser isolating valves (IS), and an acoustic kit (AKW) for noise reduction.
Performance Specifications: The document provides detailed performance data for various unit sizes, including cooling and heating capacities, input power, efficiency ratings (EER and COP), water flow rates, and pressure drops.
Energy Data: The units have SEER ratings indicating energy efficiency, with values provided for both standard and high-efficiency versions.
Electric Data: Maximum and peak current values are provided for each unit size.
General Technical Data: The units use screw compressors with R134a refrigerant, shell and tube heat exchangers, and grooved joint hydraulic connections. Sound data and dimensions are also provided.
Dimensions: Detailed dimensions and weights for each unit size are included.
See more

Catalog excerpts

HWF-1

Heat pump reversible on the water side Cooling capacity 629,5 ÷ 1438,2 kW Heating capacity 697,7 ÷ 1576,8 kW • Optimised for high condenser temperatures for example units operating in heating mode • Maximum condenser leaving water temperature: 60°C • Electronic thermostatic as standard Units for internal installation offering chilled/hot water, designed to mit air conditioning needs in residential/commercial complexes or industrial applications. Compact and flexible, perfect alignment to the requested load thanks to an accurate control algorithm. The base, the structure and the panels are made of galvanized steel treated with polyester paint RAL 9003. ° Standard A High efficiency FEATURES Operating field Production of chilled water up to -8°C of water produced on the evaporator side, but also suitable for use in heat pump mode with condenser water temperature up to 60°C. Dual-circuit unit Unit with 2 refrigerant circuits designed to provide maximum efficiency at full load, ensuring high efficiency at partial loads also and ensuring continuity in case one of the circuits stops. They are equipped with screw compressors and system and source side shell and tube heat exchangers with R134a refrigerant. Electronic expansion valve The possibility to use electronic expansion valve, offers significant benefits, especially when the chiller is working with partial loads, increasing the energy efficiency of the unit. Standard for all sizes. The presence of a programmable timer allows functioning time periods and a possible second set-point to be set. The temperature control takes place with the integral proportional logic, based on the water output temperature. AER485P1 x n° 2: RS-485 interface for supervision systems with MODBUS protocol. AERNET: The device allows the control, the management and the remote monitoring of a Chiller with a PC, smartphone or tablet using Cloud connection. AERNET works as Master while every unit connected is configured as Slave (max. 6 unit); also, with a simple click is possible to save a log file with all the connected unit datas in the personal terminal for post analysis. MULTICHILLER_EVO: Control, switch-on and switch-off system of the single chillers where multiple units are installed in parallel, always ensuring constant flow rate to the evaporators. PRV3: Allows you to control the chiller at a distance. AVX: Spring anti-vibration supports. FACTORY FITTED ACCESSORIES RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. IS: Condenser isolating valves. Mandatory accessory for units operating in heat pump mode. Factory fitted only. AKW: Acoustic kit that lowers the noise level even further, thanks to the special coating on the panelling or on those components that produce the most noise in the unit. Available for the low noise version only. pCO5 control type Microprocessor adjustment, with keyboard and LCD display,for easy access on the unit is a menu available in several languages. Adjustment includes complete management of the alarms and their log. Possibility to control two units in a Master-Slave configuration HWF-2512-5612-HP-W_Y_EE50_03

 Open the catalog to page 1
HWF-2

ACCESSORIES COMPATIBILITY Model AER485P1 x n° 2 (1) AERNET MULTICHILLER_EVO PRV3 (1) x Indicates the quantity of accessories to match. RIF: Power factor correction Ver °,A A grey background indicates the accessory must be assembled in the factory For the size of the units with the RIF accessory we ask you to contact the headquarters. IS: isolating kit Ver ° A (1) Mandatory accessory for heating mode operation A grey background indicates the accessory must be assembled in the factory Set-up: L (1) Available only in low noise version A grey background indicates the accessory must be assembled in...

 Open the catalog to page 2
HWF-3

PERFORMANCE SPECIFICATIONS HWF - ° Size Cooling performance 12 °C / 7 °C (1) Cooling capacity Input power Cooling total input current EER Water flow rate system side Pressure drop system side Water flow rate source side Pressure drop source side Heating performance 40 °C / 45 °C (2) Heating capacity Input power Heating total input current COP Water flow rate system side Pressure drop system side Water flow rate source side Pressure drop source side (1) Date 14511:2018; Water user side 12 °C / 7 °C; Water source side 30 °C / 35 °C (2) Date 14511:2018; Water user side 40 °C / 45 °C; Water source...

 Open the catalog to page 3
HWF-4

GENERAL TECHNICAL DATA Size Compressor Type Compressor regulation Number Circuits Refrigerant System side heat exchanger Type Number Source side heat exchanger Type Number System side hydraulic connections Connections (in/out) Sizes (in/out) Source side hydraulic connections Connections (in/out) Sizes (in/out) Size Set-up: ° Sound data Sound power level Sound pressure level (10 m) Set-up: L Sound data Sound power level Sound pressure level (10 m) type Type no. no. type Size Dimensions and weights A B C Empty weight Aermec si riserva la facoltà di apportare in qualsiasi momento tutte le modifiche...

 Open the catalog to page 4

All AERMEC catalogs and technical brochures

  1. FCZI-D

    5  Pages

  2. FCZ-D

    5  Pages

  3. NRG

    9  Pages

  4. WFGI

    9  Pages

  5. WFGN

    7  Pages

  6. WFI

    9  Pages

  7. WFN

    8  Pages

  8. WRL 026 -161

    5  Pages

  9. BHP

    6  Pages

  10. DUALJET

    10  Pages

  11. AERMEC FOR WINE

    20  Pages

  12. ANK

    8  Pages

  13. ANLI

    8  Pages

  14. MGW

    2  Pages

  15. NSI

    4  Pages

  16. TA

    4  Pages

  17. TS

    2  Pages

  18. Omnia Radiant

    4  Pages

  19. MHM

    4  Pages

  20. MHW

    2  Pages

  21. Technical Focus

    16  Pages

  22. All product

    404  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.