DUALJET NEW FAN COIL UNIT WITH CONTROLLED OUTLET Floor installation Environmental comfort and dynamic terminals.
Open the catalog to page 1Environmental comfort and dynamic terminals. The term environmental comfort means the particular condition of well-being determined by temperature, humidity of air, sound and lighting levels found within an environment in relation to the subjective perception of each person. Studies of environmental comfort show that optimal well-being is achieved depending on the relationship established between the subjective variables and the environmental variables. Subjective variables Relative to the individual it is the activity undertaken within the environment. Environmental variables - Air temperature...
Open the catalog to page 3The problem. One of the main causes of discomfort is the perception of a non-homogenous vertical distribution of temperature in the space. This is the situation that can happen in heating, during the winter season. The vertical intake of warm air can lead to effects of stratification: the warm air, being less dense, tends to occupy the higher part of the room leaving the lower part to the colder air with a consequent reduction of perceived comfort. In recent years there is the widespread belief that the best way to overcome this stratification of air is obtained by using under floor radiant installations...
Open the catalog to page 4Description of the tests. Aermec has subjected the new DUALJET fan coil unit to rigorous tests, both inside a Real Room, to verify the distribution of heat, as well as inside a special anechoic chamber, to verify the acoustical performance. The expected results were amply confirmed by the tests undertaken. Results With the new DUALJET fan coil unit (with downward warm air discharge) the thermal gradient is highly contained in the whole heating period and it can be noted how a steady state condition is achieved in a gradual manner with the complete absence of annoying temperature fluctuations....
Open the catalog to page 5The advantages of DUALJET. The substantial absence of the stratification phenomenon reflects on the level of comfort perceived in the space in normal conditions and avoids even the unpleasant sensation, in the presence of strong thermal gradients, when getting up from seated as there is a significant homogeneity of space temperature. Besides this the new system maintains, with respect to under floor radiant systems, all the undoubted advantages of the fan coil unit: - short system start-up time - precision in setting up and in control - single system for summer conditioning and for environmental...
Open the catalog to page 6Aermec participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com H max. speed; M med. speed; L min. speed Room air temperature 20°C d.b.; Water (in/out) 70°C/60°C; Room air temperature 20°C d.b.; Water (in/out) 45°C/40°C (EUROVENT) Room air temperature 27°C d.b./19°C w.b.; Water (in/out) 7°C/12°C (EUROVENT) Sound power level: based on mesurement in compliance with Eurovent 8/2 Sound pressure level (A-weighted) measured indoors with volume V=85m4, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Open the catalog to page 7FCZ_D - FCZI_D Dimensioni per tutte le configurazioni Height (A) mm 486 486 486 486 Height (A+D with feet) mm 576 576 576 576 Weight (without feet) kg 15 17 23 22 For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
Open the catalog to page 8Total comfort. Maximum efficiency. Minimum consumption This is Aermec. Italian technology in the service of your comfort. REAL ROOM - VERIFICATION TEST OF HEAT DISTRIBUTION
Open the catalog to page 9Aermec S.p.A. Via Roma, 996 37040 Bevilacqua (VR) - Italia Tel. + 39 0442 633111 Fax +39 0442 93577 [email protected] All specifications are subject to change without prior notice. Although every effort has been made to ensure accuracy, Aermec does not assume responsibility or liability for eventual errors or omissions.
Open the catalog to page 105 Pages
5 Pages
9 Pages
4 Pages
9 Pages
7 Pages
9 Pages
8 Pages
5 Pages
21 Pages
6 Pages
20 Pages
12 Pages
40 Pages
92 Pages
8 Pages
8 Pages
15 Pages
8 Pages
2 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
16 Pages
404 Pages
48 Pages
194 Pages
4 Pages
2 Pages
4 Pages
2 Pages