Catalog excerpts

These units allow to extract a certain amount of exhaust air from the room and supply an equivalent quantity of fresh air.A crossflow aluminium plate exchanger assures an efficient heat exchange between exhaust and fresh air: therefore the fresh air is pre-heated or pre-cooled according to the seasons. The supply air is filtered before entering the heat recovery exchanger that is protected with a synthetic filter also at the exhaust air side.The supply air can optionally be re-heated with a hot water coil or with an electric coil.7 sizes are available: UR E : same as standard versions and equip-ped with electric heating coil with aluminium fins and double safety thermostatՕDouble suction centrifugal fans coupleddirectly to the electric motors, equipped with adjustable speeds via an electronic control tovary the flow rateG3 class synthetic filter on the air outlet ՕAluminium plate reheater housed in the con-densate tray that is easily removed from the bottomG3 class synthetic filter on the fresh air intake ՕSelf-bearing panels made of galvanized platewith injected polyurethane insulation and thickness 20 mm.Galvanized condensate tray ՕFans can be inspected from the bottomFilters can be removed from the bottom forcleaning or replacementՕTwo versions available for horizontal andvertical installation (it is not possible to install the cooling coil accessories and silencers for the vertical installation)Electronic Regulator with Slave Applicationallowing continuous variation of rotation speed and air flow rate > UR : standard version UR W : same as standard version and equip-ped with water heating coil with copper tubes and 3 rows aluminium fins. Not to be used with chilled water >
Open the catalog to page 1
Compatibility of accessoriesHorizontal installation: UR 35UR 55UR 75UR 100UR 150UR 210UR 330 BF 35 բܔ BF 55 ✔ BF 75 ✔ BF 100 ✔ BF 150 ✔ BF 210 ✔ BF 330 ✔ FGC 1 ✔✔✔ FGC 2 ✔✔ G4 35 ✔ G4 55 ✔ G4 75 ✔ G4 100 ✔ G4 150 ✔ G4 210 ✔ G4 330 ✔ MPW 35 ✔ MPW 55 ✔ MPW 75 ✔ MPW 100 ✔ MPW 150 ✔ MPW 210 ✔ MPW 330 ✔ MPX 35 ✔ MPX 55 ✔ MPX 75 ✔ MPX 100 ✔ MPX 150 ✔ MPX 210 ✔ MPX 330 ✔ SE 1 ✔✔ SE 2 ✔ SE 3 ✔✔ SE 4 ✔ SE 5 ✔ SU 1 ✔✔ SU 2 ✔ SU 3 ✔✔ SU 4 ✔ SU 5 ✔ Vertical installation: UR 35UR 55UR 75UR 100UR 150UR 210UR 330 FGC 1 ✔✔✔ FGC 2 ✔✔ G4 35 ✔ G4 55 ✔ G4 75 ✔ G4 100 ✔ G4 150 ✔ G4 210 ✔ G4 330 ✔ SE 1 ✔✔ SE 2 ✔...
Open the catalog to page 2All AERMEC catalogs and technical brochures
-
FCZI-D
5 Pages
-
FCZ-D
5 Pages
-
NRG
9 Pages
-
HWF
4 Pages
-
WFGI
9 Pages
-
WFGN
7 Pages
-
WFI
9 Pages
-
WFN
8 Pages
-
WRL 026 -161
5 Pages
-
Aermec Company Profile
21 Pages
-
BHP
6 Pages
-
DUALJET
10 Pages
-
AERMEC FOR WINE
20 Pages
-
Aermec Data Centre solutions
12 Pages
-
Aermec Guida Idronica
40 Pages
-
Aermec Split System VRF
92 Pages
-
ANK
8 Pages
-
ANLI
8 Pages
-
Aermec Company Profile
15 Pages
-
Variable multi flow
8 Pages
-
MGW
2 Pages
-
NSI
4 Pages
-
TA
4 Pages
-
TS
2 Pages
-
Omnia Radiant
4 Pages
-
MHM
4 Pages
-
MHW
2 Pages
-
Technical Focus
16 Pages
-
All product
404 Pages
-
Split System and VRF systems
48 Pages
-
GPUY:products guide 2012
194 Pages
Archived catalogs
-
Data sheet - Fan coils
4 Pages
-
Data sheet - Dehumidifier
2 Pages
-
Data sheet- split system
2 Pages