BHP - 1

Air/Water split type reversible heat pump Cooling capacity 3.2 - 8.5 kW Heating capacity 4.0 - 9.5 kW A • Indoor unit available in two versions with or without DHW storage tank • New environmentally friendly refrigerant gas R32 • Production of hot water up to 60°C • Anti-legionella function • Multi-language control panel DESCRIPTION BHP is the new "split" type inverter heat pump system, more efficient than standard boiler systems as it guarantees sustainable, efficient heating, cooling and domestic hot water supply in every season. BHP is designed to meet the needs of both the new constructions market and the renovation market, replacing or working alongside conventional boilers. The system can be installed in systems with any hydronic terminal, and is already supplied with the main hydraulic components, thus facilitating final installation. The indoor unit comes in two versions: wall-mounting (without DHW storage tank but complete with a 3-way DHW-system diverting valve), to be connected to an external DHW storage tank, or with base (complete with DHW storage tank). FEATURES Main hydraulic components BHP outdoor unit — inverter compressor, — finned pack heat exchanger with copper pipes and aluminium fins, with protective Golden Fin treatment, — economiser, — electronic valve, — DC axial brushless fan, — base electric heater. BHP_W internal wall unit — plate heat exchanger, — flow switch, — inverter pump, — expansion tank, — drain valve, — safety valve, — supplementary electric heater, — 3-way valve, — DHW-system connections. — water filter, supplied (installation is compulsory). BHP_F indoor unit with base — plate heat exchanger, — flow switch, — inverter pump, — expansion tank, — drain valve, — safety valve, — supplementary electric heater, — 3-way valve, — DHW-system connections, — water filter, supplied (installation is compulsory), — DHW storage tank of 185 litres with coil and supplementary electric heater, and anti-legionella function. — tank with electronic anode. The indoor and outdoor units are connected by means of suitably sized cooling lines (supplied by the installer), and the cooling circuit uses R32 refrigerant with low GWP. Operating limits Full load operation down to -25°C (outside air temperature in winter), and up to 48°C in summer. Adjustments Adjustment via a multi-language touch-screen control panel: — Management of a 3-way diverting valve for the production of domestic hot water. — Management of a 2-way valve (not supplied) for shutting off part of the system. — Weekly and hourly programming. — Auto-restart function. — Emergency operation. — Quick hot water function, for quickly heating domestic hot water. — Weather Dependent Mode for climatic adjustment. — Quiet function for reduced noise operation, programmable with a timer.

Open the catalog to page 1
BHP - 2

— Condensation Control. — When the anti-legionella cycle is activated (it's easily set via the control panel), the whole tank is heated once a week to a temperature (max. 70°C) that weakens the bacteria responsible for the infection. ACCESSORIES DHWT300S: (230V~50Hz) DHW storage tank in enamelled steel. Single-phase power supply, tank capacity 300 litres with main and secondary coils and 3 kW back-up electric heater. Magnesium sacrificial anode. Indoor installation, as indicated in the installation manual. IC-2P: Connector for communication via Mod Bus or VMF -485LINK. Accessory compulsory...

Open the catalog to page 2
BHP - 3

BHP_F: CONNECTION TO THE FLOOR SYSTEM AND FCU HYDRAULIC COMPONENTS SUPPLIED AS STANDARD IN THE INDOOR UNIT Plate heat exchanger Flow switch Inverter pump Expansion tank Drain valve Safety valve Supplementary electric heater 3-way valve DHW-system connections HYDRAULIC COMPONENTS RECOMMENDED OUTSIDE THE UNIT (AT THE INSTALLER'S RESPONSIBILITY) Anti-vibration joints Interception taps Room thermostat 2-way valve Safety valve NOT supplied (installation is mandatory) Water filter NOT supplied (installation is mandatory) Domestic hot water High temperature line SUPPLIED HYDRAULIC COMPONENTS Water...

Open the catalog to page 3
BHP - 4

Indoor unitBHP060WBHP060WBHP100WBHP100W Performance in cooling mode 23°C / 18°C (1) (1) Data 14511; Heat exchanger water (services side) 23°C / 18°C; External air 35°C (2) Data 14511; Heat exchanger water (service side) 30°C / 35°C; Outside air 7°C D.B./6°C W.B. ENERGY DATA EU 811/2013 performance in average weather conditions - 35°C - Pdesignh < 70 kW (1) Pdesignh_kW_5_ Energy efficiency class_A+++_ EU 811/2013 performance in average weather conditions - 55°C - Pdesignh < 70 kW (2) Pdesignh_kW_5_ Energy efficiency class_A±±_ Performance as combined heat generator_ Bleeding profile_XL_...

Open the catalog to page 4
BHP - 5

WALL INDOOR UNIT Indoor unit_ Electric data_ Nominal input power (1) Electric heater_ Power of the single heater Heat exchanger, service side Type_ Unit / system input_ Mains water input_ Unit / system output_ Expansion tank_ Maximum pressure_ Sound Data_ Sound power_ Power supply_ Power supply_ type no type type type type _Plates _1_ _G1 female G1 female_ (1) The nominal input power (nominal input current) is the maximum electrical input power (maximum input current) from the system, in accordance with standards EN60335-1 and EN60335-2-40. OUTDOOR UNIT Outdoor unit Electric data Nominal...

Open the catalog to page 5
BHP - 6

OUTDOOR UNIT DIMENSIONS AND WEIGHTS BHP_F Indoor unit_ OUTDOOR UNIT DIMENSIONS AND WEIGHTS Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293577 www.aermec.com Aermec reserves the right to make any modifications deemed necessary. All data is subject to change without notice. Aermec does not assume responsibility or liability for errors or omissions.

Open the catalog to page 6

All AERMEC catalogs and technical brochures

  1. HWF

    4 Pages

  2. WFGI

    9 Pages

  3. WFGN

    7 Pages

  4. WFI

    9 Pages

  5. WFN

    8 Pages

  6. WRL 026 -161

    5 Pages

  7. DUALJET

    10 Pages

  8. ANK

    8 Pages

  9. ANLI

    8 Pages

  10. MGW

    2 Pages

  11. NSI

    4 Pages

  12. TA

    4 Pages

  13. TS

    2 Pages

  14. MHM

    4 Pages

  15. MHW

    2 Pages

  16. All product

    404 Pages

Archived catalogs