Catalog excerpts

ANLI - 1

Air-cooled - axial fans Scroll compressors - R410A Cooling capacity 29kW - Heating capacity 31kW

Open the catalog to page 1
ANLI - 2

ANLI INVERTER Greater wellbeing, lower energy consumption • Designed for use with all terminals (radiant heating panels, fan coils and radiators) and able to produce domestic hot water Manages variable water flow systems (also available with inverter-driven pump): to save more than 50% on pumping costs Reduces heating costs by up to 30% compared with traditional systems (condensing boilers) Lower weight and smaller dimensions thanks to the use of refrigerant R410A and absence of the storage tank Greater climate and acoustic comfort Traditional ON-OFF Chiller -20% Reduction in carbon dioxide...

Open the catalog to page 2
ANLI - 3

FAN COILS Living area and Sleeping area ON Traditional ON-OFF Chiller 2000 Watt Electricity consumption adjusts instantly on demand. Thanks to the inverter technology, the power needed for heating or cooling is modulated, meaning that electrical consumption is in continuous change. In this way, it becomes even easier to manage many simultaneous electrical loads, whilst avoiding exceeding the maximum electricity consumption allowed under the electricity provider’s contract. FAN COILS Living area ON Traditional ON-OFF Chiller

Open the catalog to page 3
ANLI - 4

-20°C ANNUAL SAVINGS IN ELECTRICITY CONSUMPTION COMPARED WITH TRADITIONAL ON-OFF SYSTEMS -50°C THE NOISE LEVEL REDUCTION, AT APPROX. 3 DB (A), ESPECIALLY APPRECIATED DURING NIGHT-TIME OPERATION -20% REDUCTION IN CO2 EMISSIONS (CARBON DIOXIDE C2ONTRIBUTES TO THE GREENHOUSE EFFECT) NIGHT-TIME SILENCE ANLI Inverter e ANLI LOWER BILLS Thanks to the Inverter technology, the electrical "brushless" DC motor with permanent magnets and the electronic thermostatic valve, the heat pumps and chillers of the ANLI series are able to modulate continuously the power needed for heating and cooling from 35%...

Open the catalog to page 4
ANLI - 5

+20% THE INCREASE IN SEASONAL ENERGY EFFICIENCY (ESEER-EUROPEAN SEASONAL ENERGY EFFICIENCY RATIO) COMPARED WITH NORMAL ON-OFF WATER CHILLERS -70% THE REDUCTION IN START-UP POWER DEMAND COMPARED WITH RANGES WITH ON-OFF COMPRESSORS -25% THE AVERAGE REDUCTION IN WEIGHT AND DIMENSIONS COMPARED WITH TRADITIONAL RANGES LOWER WEIGHT AND SMALLER DIMENSIONS The use of the specific high energy fluid refrigerant R410A and absence of water storage make the ANLI Inverter smaller and lighter compared to the equivalent ON-OFF series with storage. RESPECT FOR THE ENVIRONMENT Thanks to greater energy...

Open the catalog to page 5
ANLI - 6

VARIATION OF THE NOISINESS AT LOAD CHANGE Under nominal conditions the ANLI Inverter series is, on average, quieter than the ON-OFF series, but what really makes the difference is the change in the noise level in response to a change in load. While a traditional On-Off appliance always emits the same level of noise, the ANLI Inverter series gradually reduces the noise it makes as the power required decreases. This brings a significant benefit during night-time operation, when the load is naturally reduced and the need for silence is considerably greater compared with daytime hours. INVERTER...

Open the catalog to page 6
ANLI - 7

Total input power (1) kW Cooling Energy Class Eurovent Water flow rate (1) l/h Total input power (2) kW Heating Energy Class Eurovent Water flow rate (2) l/h Total input power (3) kW Cooling Energy Class Eurovent Water flow rate Pressure drop Heating capacity Total input power Heating Energy Class Eurovent Water flow rate Pressure drop Performance under average climatic conditions (Average Energy Class Eurovent Classe Efficienza Energetica Date (14511:2013) (1) Water evaporator 12°C/7°C, External air 35°C (2) Water condenser 40°C/45°C, External air 7°C b.s./6°C b.u. (3) Water evaporator...

Open the catalog to page 7
ANLI - 8

Aermec S.p.A. Via Roma 996 All specifications are subject to change without prior notice. Although 37040 Bevilacqua (VR) - Italia every effort has been made to ensure accuracy, Aermec does not assume Tel + 39 0442 633111 responsibility or liability for eventual errors or omissions.

Open the catalog to page 8

All AERMEC catalogs and technical brochures

  1. HWF

    4 Pages

  2. WFGI

    9 Pages

  3. WFGN

    7 Pages

  4. WFI

    9 Pages

  5. WFN

    8 Pages

  6. WRL 026 -161

    5 Pages

  7. BHP

    6 Pages

  8. DUALJET

    10 Pages

  9. ANK

    8 Pages

  10. MGW

    2 Pages

  11. NSI

    4 Pages

  12. TA

    4 Pages

  13. TS

    2 Pages

  14. MHM

    4 Pages

  15. MHW

    2 Pages

  16. All product

    404 Pages

Archived catalogs