AERMEC DATA CENTRE SOLUTIONS THE COMPLE TE RANGE OF AERMEC SOLUTIONS FOR DATA CENTRES

Open the catalog to page 1
Aermec Data Centre solutions - 2

GLOBAL DATA CENTRE IP TRAFFIC WILL TRIPLE WITHIN 5 YEARS • The need for bigger online storage resources; • The new possibility to analyze a bigger amount of data (a phenomenon called “big data analysis”, applied in the analysis of complex systems such as weather forecasts or social behavior prediction); • The growing demand for cloud requirements. Cloud data centre traffic will grow with a CAGR of 35% from 2012 to 2017, at a faster rate than the traditional IP traffic, establishing a 4,5-fold growth during this period. Zettabytes / Year Global data centre IP traffic has set a constant...

Open the catalog to page 2
Aermec Data Centre solutions - 3

DATA CENTRE COOLING REQUIREMENTS Data centre cooling systems represent a significant portion of a facility’s capital expenditure and use a substantial amount of energy. ASHRAE (American Society of Heating, Refrigerating, and Air-conditioning Engineers) publishes specific guidelines for temperature and humidity control within data centres. The 3rd Edition of the Thermal Guidelines for Data Processing Environments defines a recommended operating window and four allowable ranges, designated A1 through A4. The new allowable ranges (A3 and A4) are intended to remove obstacles to new data centre...

Open the catalog to page 3
Aermec Data Centre solutions - 4

AERMEC: TECHNOLOGY YOU CAN TRUST Aermec, founded in 1961, counts amongst Europe’s longest established Air Conditioning suppliers. A true pioneer, with over 50 years of innovative customer focused solutions, Aermec is present on all continents worldwide and with Subsidiaries and Affiliates in France, Germany, Italy, the Netherlands, Poland, Russia, Spain and the UK. The Aermec Group of companies includes a total of 6 centres of excellence spanning the full air conditioning portfolio, with a turnover in excess of €305m and over 1600 employees. A total of 8 Group manufacturing locations create...

Open the catalog to page 4
Aermec Data Centre solutions - 5

Aermec’s 2MW testing facilities Aermec’s advanced labs extend to 2MW cooling capacity per single unit in what is probably Europe’s largest test facility, which will offer Eurovent certification. Specific labs within Aermec also cater for extreme temperature testing, ventilation and heat exchange measurements, noise level verification and vibration testing. Aermec furthermore utilizes a simulated data centre installation including both a data hall simulator and an ambient air simulator recreating typical ambient temperature and humidity conditions. AERMEC & DATA CENTRES Aermec’s experience...

Open the catalog to page 5
Aermec Data Centre solutions - 6

DATA CENTRE DESIGN SOLUTIONS According to the specific data centre characteristics, the geographical and thus ambient conditions in which the data centre is located, and the individual target requirements of the User, differing data centre cooling typologies can be applied. CRAC Condenser or Dry Cooler CHILLED WATER SYSTEMS DIRECT EXPANSION SYSTEMS Precision Air Conditioners featuring one or more chilled water coils (CRAH), operating in combination with one or more external water chillers. The water chiller can be in standard or freecooling configuration. In alternative to the CRAH units,...

Open the catalog to page 6
Aermec Data Centre solutions - 7

DESIGNING YOUR OPTIMISED DATA CENTRE An optimised data centre starts with a clear vision as to the overall project objectives: Aermec’s unique ACES energy simulation software supports this process by evaluating the performances of differing data centre solutions. All of these inputs are considered to generate a customized and optimized proposal. ACES furthermore cross compares the performance of multiple chillers, the PAC system, AHU and server control devices, primary and secondary pumping equipment, system lay out, etc. ACES considers variable loads and all year round operation,...

Open the catalog to page 7
Aermec Data Centre solutions - 8

THE AERMEC DATA CENTRE SOLUTIONS WATER CHILLERS Aermec water chillers offer a wide range of cooling capacities to meet the needs of small, medium and large data centres. Free-cooling technology exploits the favourable environmental conditions to supply chilled water without the use of mechanical cooling, maximizing efficiencies and energy savings. NSM_I (285 - 1204kW) Chillers with inverter screw compressors with shell & tube heat exchangers Water produced up -6°C to +15°C - Outdoor air temperature up -10°C to +50°C Standard and free-cooling configurations NSM (302 - 2100kW) Chillers with...

Open the catalog to page 8
Aermec Data Centre solutions - 9

PRECISION AIR CONDITIONERS Aermec’s wide range of Precision Air Conditioners cater for the differing data room conditioning needs. Efficient and flexible product solutions can be applied within numerous differing configurations. A wide range of options and accessories allows perfect alignment according to the needs of individual installations, providing complete and optimised control of the temperature, humidity and indoor air quality within data centres. AIR-COOLED DIRECT EXPANSION CONFIGURATIONS Cooling range 7 – 183kW Down-flow and Up-flow versions DC inverter compressors, EC fans,...

Open the catalog to page 9
Aermec Data Centre solutions - 10

AERMEC CHILLERS ENSURE LOWEST PUE’S The most evolved free-cooling technologies Free-cooling translates into cooling for free, the more this can be exploited the higher the energy savings. Aermec optimises free-cooling, a concept whereby ambient air is used for cooling when the ambient temperature is lower than the data hall air (direct free-cooling) or the chilled water (indirect free-cooling). In hydronic solutions free-cooling starts when external conditions ensure even a minimum coverage of the thermal load requirements. Thanks to the application of modulating free-cooling to maximize...

Open the catalog to page 10
Aermec Data Centre solutions - 11

Chiller + Standard Dry Cooler Chiller + Adiabatic Dry Cooler Chiller Freecooling Chiller freecooling Chiller freecooling with Integrated Adiabatic Panels Energy saving with the adiabatic dry cooler would be wider with higher water temperature in the cooling process. The Free Cooling chiller solution is always the most advantageous, maximising the energy savings in both relative (compared with the other solutions) and absolute terms. (3) Energy annual consumption includes losses of load on air side due to adiabatic panels. (1) (2) Data Refers to London (UK) for a chillers units with 500kW...

Open the catalog to page 11

All AERMEC catalogs and technical brochures

  1. HWF

    4 Pages

  2. WFGI

    9 Pages

  3. WFGN

    7 Pages

  4. WFI

    9 Pages

  5. WFN

    8 Pages

  6. WRL 026 -161

    5 Pages

  7. BHP

    6 Pages

  8. DUALJET

    10 Pages

  9. ANK

    8 Pages

  10. ANLI

    8 Pages

  11. MGW

    2 Pages

  12. NSI

    4 Pages

  13. TA

    4 Pages

  14. TS

    2 Pages

  15. MHM

    4 Pages

  16. MHW

    2 Pages

  17. All product

    404 Pages

Archived catalogs