Catalog excerpts
AWN ECO+ - VENTILATION SYSTEM EXHAUST AIR SYSTEM WITH HEAT RECOVERY AND HEAT GENERATION
Open the catalog to page 1AWN ECO+ CENTRAL VENTILATION UNIT WITH INTEGRATED EXHAUST AIR HEAT PUMP Compact Exhaust air heat pump for heat recovery and production. Smart, Heat pump control source oriented – ReSource Control Fully integrated ventilation unit with exhaust air heat pump for outdoor installation. The source-oriented heat pump control – ReSource Control balances the heat pump performance to the available exhaust volume air flow. Thus, the operation is almost continuous and high durations and efficiencies can be achieved. Low Energy consumption: With EC engine, EnEV requirements are be complied. Special...
Open the catalog to page 21. Humidity-controlled external air ducts 2. Heat Exchanger + EC fan + Heat Pump 3. Exhaust unit 4. Heating water pipe leads to heating system Preventive fire protection elements must be installed and not shown in this schematic diagram !
Open the catalog to page 3PRODUCT PORTFOLIO: FAN WITH HEAT RECOVERY Aereco has extended its range of products in the category of „air extraction system with heat recovery“. There are three possible models for the AWN range: An air extraction module with heat exchanger without heat pump An air extraction module with heat exchanger and a heat pump. An air extraction module with heat exchanger and an integrated heat pump For this model (formerly called AWN-RV and AWN-DV), the AWN can be connected to an external heat pump by means of brine buffer. This model includes a heat pump specially Designed to be used with an...
Open the catalog to page 4FEATURES AWN Basic Designed for indoor and outdoor use: The air extraction module and its heat exchanger are available in RV or DV versions Flexible combination: several AWN Basic can be combined with a Connect heat pump Can be combined with existing brine / water heat pumps via brine buffer AWN Connect Flexible installation: ventilation unit with heat exchanger and heat pump can be installed separately Designed for indoor and outdoor use: The air extraction unit and its heat exchanger are available in RV or DV versions ReSource Control: intelligent control adapts the operation of the heat...
Open the catalog to page 5Ventilation unit, heat exchanger and source-controlled heat pump Informations Installation Recommanded setting pressure Max. airflow for device (75%) at 130Pa Modulation range heat output (A20W35) Modulation range - exhaust air Minimum exhaust airflow required Max heating flow temperature Sound pressure level at 3m distance (75%) – Lp, A Sound power level of the device suction side (75%) – Lw, A Connection to the main station Exhaust air – pipe connection (DN) Exhaust air – connection options Integrated elastic connector for pipe Brine – Pipe connection Brine – Max. Airflow Brine –...
Open the catalog to page 6manque tableau Differential pressure switch, filter monitoring Main switch Smoke detector Compressor housing Plate-type heat exchanger Terminals Exhaust air heat pump - return Exhaust air heat pump - supply Condensate drain
Open the catalog to page 7AWN ECO+ 121 Informations Installation Recommanded setting pressure Max. airflow for device (75%) at 130Pa Modulation range heat output (A20W35) Modulation range - exhaust air Minimum exhaust airflow required Max heating flow temperature Sound pressure level at 3m distance (75%) – Lp, A Sound power level of the device suction side (75%) – Lw, A Connection to the main station Exhaust air – pipe connection (DN) Exhaust air – connection options Integrated elastic connector for pipe Brine – Pipe connection Brine – Max. Airflow Brine – Permitted antifreeze Brine – Available external delivery...
Open the catalog to page 8Differential pressure switch, filter monitoring Main switch Smoke detector Compressor housing Plate-type heat exchanger Terminals Exhaust air heat pump - return Exhaust air heat pump - supply Condensate drain
Open the catalog to page 9AWN ECO+ 131 Informations Installation Recommanded setting pressure Max. airflow for device (75%) at 130Pa Modulation range heat output (A20W35) Modulation range - exhaust air Minimum exhaust airflow required Max heating flow temperature Sound pressure level at 3m distance (75%) – Lp, A Sound power level of the device suction side (75%) – Lw, A Connection to the main station Exhaust air – pipe connection (DN) Exhaust air – connection options Integrated elastic connector for pipe Brine – Pipe connection Brine – Max. Airflow Brine – Permitted antifreeze Brine – Available external delivery...
Open the catalog to page 10Differential pressure switch, filter monitoring Main switch Smoke detector Compressor housing Plate-type heat exchanger Terminals Exhaust air heat pump - return Exhaust air heat pump - supply Condensate drain
Open the catalog to page 11FLY698_AWN_ECO+_GB – Copyright Aereco – Images: Aereco – All data and pictures in this document are non contractual and are subject to change without prior notice.
Open the catalog to page 12All Aereco Ventilation Limited catalogs and technical brochures
-
BXC-EF
2 Pages
-
BXC-EC
2 Pages
-
BXC-EG
2 Pages
-
V4A PREMIUM
2 Pages
-
V2A
2 Pages
-
BXC
2 Pages
-
GBP
2 Pages
-
G2H
2 Pages
-
S-PRE/Day-Night/T Modbus
9 Pages
-
VCZ
4 Pages
-
AWN CONNECT
20 Pages
-
AWN BASIC
16 Pages
-
EAH²
2 Pages
-
EHT
2 Pages
-
EHA²
2 Pages
-
EMM²
2 Pages
-
VCZ - VTZ Catalogue
20 Pages