AWN CONNECT - VENTILATION SYSTEM EXHAUST AIR SYSTEM WITH HEAT RECOVERY AND HEAT GENERATION

Open the catalog to page 1
AWN CONNECT - 2

AWN CONNECT CENTRAL VENTILATION UNIT WITH INTEGRATED EXHAUST AIR HEAT PUMP Separate fan unit and heat pump for greater flexibility Exhaust air heat pump efficient for heat generation and heat recovery The AWN Connect includes the AWN Basic (DV / RV), and a separate heat pump specifically designed for AWN: Connect WP. In combination with an air extraction module (AWN Basic) for outdoor or indoor installation, the AWN Connect system can be flexibly adapted to individual building projects. In addition, several AWN Basic can be used with a unique Connect WP. Ventilation units with exhaust air...

Open the catalog to page 2
AWN CONNECT - 3

1. Humidity-controlled external air ducts 2. Heat Exchanger + EC fan 3. Exhaust unit 4. Brine pipeline leads to Aereco heat pump Preventive fire protection elements must be installed and not shown in this schematic diagram !

Open the catalog to page 3
AWN CONNECT - 4

PRODUCT PORTFOLIO: FAN WITH HEAT RECOVERY Aereco has extended its range of products in the category of „air extraction system with heat recovery“. There are three possible models for the AWN range: An air extraction module with heat exchanger without heat pump An air extraction module with heat exchanger and a heat pump. An air extraction module with heat exchanger and an integrated heat pump For this model (formerly called AWN-RV and AWN-DV), the AWN can be connected to an external heat pump by means of brine buffer. This model includes a heat pump specially Designed to be used with an...

Open the catalog to page 4
AWN CONNECT - 5

FEATURES AWN Basic Designed for indoor and outdoor use: The air extraction module and its heat exchanger are available in RV or DV versions Flexible combination: several AWN Basic can be combined with a Connect heat pump Can be combined with existing brine / water heat pumps via brine buffer AWN Connect Flexible installation: ventilation unit with heat exchanger and heat pump can be installed separately Designed for indoor and outdoor use: The air extraction unit and its heat exchanger are available in RV or DV versions ReSource Control: intelligent control adapts the operation of the heat...

Open the catalog to page 5
AWN CONNECT - 6

Exhaust air heat recovery module (ventilation unit and heat exchanger) AWN DV-A40 Basic 101 Set up Sound power level Housing radiation LWA* at 100 / 75 / 50% nominal air flow rate Sound power level suction side LWA * at 100 / 75 / 50% nominal air volume flow Sound pressure level LpA , 3 m away from the device * at 100 / 75 / 50% nominal air volume flow Corresponding estimated living space for exchange rate 0.5 1/h, 2.5m ceiling Max. Heat extraction per year at brine inlet temperature 0 ° C, Brine flow 1 m³ / h, air flow 1833 m³ / h Heat recovery rate (brine inlet temperature 7 ° C / 0 ° C)...

Open the catalog to page 6
AWN CONNECT - 7

AWN-Top cover opened

Open the catalog to page 7
AWN CONNECT - 8

Exhaust air heat recovery module (ventilation unit and heat exchanger) AWN DV-A50 Basic 101 Set up Sound power level Housing radiation LWA* at 100 / 75 / 50% nominal air flow rate Sound power level suction side LWA * at 100 / 75 / 50% nominal air volume flow Sound pressure level LpA , 3 m away from the device * at 100 / 75 / 50% nominal air volume flow Corresponding estimated living space for exchange rate 0.5 1/h, 2.5m ceiling Max. Heat extraction per year at brine inlet temperature 0 ° C, Brine flow 1 m³ / h, air flow 1833 m³ / h Heat recovery rate (brine inlet temperature 7 ° C / 0 ° C)...

Open the catalog to page 8
AWN CONNECT - 9

AWN-Top cover opened

Open the catalog to page 9
AWN CONNECT - 10

Exhaust air heat recovery module (ventilation unit and heat exchanger) AWN DV-A70 Basic 101 Set up Sound power level Housing radiation LWA* at 100 / 75 / 50% nominal air flow rate Sound power level suction side LWA * at 100 / 75 / 50% nominal air volume flow Sound pressure level LpA , 3 m away from the device * at 100 / 75 / 50% nominal air volume flow Corresponding estimated living space for exchange rate 0.5 1/h, 2.5m ceiling Max. Heat extraction per year at brine inlet temperature 0 ° C, Brine flow 1 m³ / h, air flow 1833 m³ / h Heat recovery rate (brine inlet temperature 7 ° C / 0 ° C)...

Open the catalog to page 10
AWN CONNECT - 11

AWN-Top cover opened

Open the catalog to page 11
AWN CONNECT - 12

AWN RV-A40 BASIC 100 / 101 Exhaust air heat recovery module (ventilation unit and heat exchanger) Set up Energetic data Corresponding estimated living space for exchange rate 0.5 1/h, 2.5m ceiling Sound power level Housing radiation LWA* at 100 / 75 / 50% nominal air flow rate Sound pressure level LpA , 3m away from the device * at 100 / 75 / 50% nominal air volume flow Max. Heat extraction per year at brine inlet temperature 0 ° C, Brine flow 1 m³ / h, air flow 1833 m³ / h Heat recovery rate (brine inlet temperature 7 ° C / 0 ° C) according to DIN EN 13141-7 Features Sound pressure level...

Open the catalog to page 12
AWN CONNECT - 14

AWN RV-A50 BASIC 100 / 101 Exhaust air heat recovery module (ventilation unit and heat exchanger) Set up Energetic data Corresponding estimated living space for exchange rate 0.5 1/h, 2.5m ceiling Sound power level Housing radiation LWA* at 100 / 75 / 50% nominal air flow rate Sound pressure level LpA , 3m away from the device * at 100 / 75 / 50% nominal air volume flow Max. Heat extraction per year at brine inlet temperature 0 ° C, Brine flow 1 m³ / h, air flow 1833 m³ / h Heat recovery rate (brine inlet temperature 7 ° C / 0 ° C) according to DIN EN 13141-7 Features Sound pressure level...

Open the catalog to page 14
AWN CONNECT - 16

manque tableau AWN CONNECT Source controlled heat pump Set up Minimum volume exhaust air (effective) Energetic data COP (A20/W40)* Modulation range heat output (A20/W35) Sound pressuve level, housing radiation LWA Sound pressure level at in 3m distance - LpA Contact for enable signal Minimum volume of exhaust air Features Electrical data Max. current consumption Supply voltage Max. power consumption Brine circuit Feed pump Brine circuit - water volume flow Brine circuit - available ext. delivery pressure Brine circuit - water connections Surge tank Ethylene glycol Cooling circuit...

Open the catalog to page 16
AWN CONNECT - 17

AWN CONNECT Combination heat pump / ventilation unit Ventilation unit installation Air flow range (effective volume flow) Ventilator model Heat pump model All data for exhaust air of 20° C and 50% relative humidity. Dimensions

Open the catalog to page 17

All Aereco Ventilation Limited catalogs and technical brochures

  1. BXC-EF

    2 Pages

  2. BXC-EC

    2 Pages

  3. BXC-EG

    2 Pages

  4. V4A PREMIUM

    2 Pages

  5. V2A

    2 Pages

  6. BXC

    2 Pages

  7. GBP

    2 Pages

  8. G2H

    2 Pages

  9. VCZ

    4 Pages

  10. AWN ECO+

    12 Pages

  11. AWN BASIC

    16 Pages

  12. EAH²

    2 Pages

  13. EHT

    2 Pages

  14. EHA²

    2 Pages

  15. EMM²

    2 Pages