AWN BASIC - VENTILATION SYSTEM EXHAUST AIR SYSTEM WITH HEAT RECOVERY AND HEAT GENERATION
Open the catalog to page 1AWN BASIC CENTRAL VENTILATION UNIT WITH EXHAUST HEAT EXCHANGER Air extraction unit with heat recovery To be combined with a suitable heat pump Recovery of extracted air energy for heating or domestic hot water In order to effectively dissipate heat lost in the heat exchanger, it must be cooled as much as possible with cold brine. On the other hand, the brine temperature must then be raised to a usable level in order to effectively introduce heat into the building. The AWN Basic must always be associated with a suitable heat pump. The Aereco exhaust air heat pump is particularly suitable for...
Open the catalog to page 2BRINE BUFFER 1. Humidity-controlled external air ducts 2. Heat Exchanger + EC fan 3. Exhaust unit 4. Heat Pump 5. Brine buffer Preventive fire protection elements must be installed and not shown in this schematic diagram !
Open the catalog to page 3PRODUCT PORTFOLIO: FAN WITH HEAT RECOVERY Aereco has extended its range of products in the category of „air extraction system with heat recovery“. There are three possible models for the AWN range: An air extraction module with heat exchanger without heat pump An air extraction module with heat exchanger and a heat pump. An air extraction module with heat exchanger and an integrated heat pump For this model (formerly called AWN-RV and AWN-DV), the AWN can be connected to an external heat pump by means of brine buffer. This model includes a heat pump specially Designed to be used with an...
Open the catalog to page 4FEATURES AWN Basic Designed for indoor and outdoor use: The air extraction module and its heat exchanger are available in RV or DV versions Flexible combination: several AWN Basic can be combined with a Connect heat pump Can be combined with existing brine / water heat pumps via brine buffer AWN Connect Flexible installation: ventilation unit with heat exchanger and heat pump can be installed separately Designed for indoor and outdoor use: The air extraction unit and its heat exchanger are available in RV or DV versions ReSource Control: intelligent control adapts the operation of the heat...
Open the catalog to page 5Exhaust air heat recovery module (ventilation unit and heat exchanger) AWN DV-A40 Basic 101 Set up Sound power level Housing radiation LWA* at 100 / 75 / 50% nominal air flow rate Sound power level suction side LWA * at 100 / 75 / 50% nominal air volume flow Sound pressure level LpA , 3 m away from the device * at 100 / 75 / 50% nominal air volume flow Corresponding estimated living space for exchange rate 0.5 1/h, 2.5m ceiling Max. Heat extraction per year at brine inlet temperature 0 ° C, Brine flow 1 m³ / h, air flow 1833 m³ / h Heat recovery rate (brine inlet temperature 7 ° C / 0 ° C)...
Open the catalog to page 6AWN-Top cover opened
Open the catalog to page 7Exhaust air heat recovery module (ventilation unit and heat exchanger) AWN DV-A50 Basic 101 Set up Sound power level Housing radiation LWA* at 100 / 75 / 50% nominal air flow rate Sound power level suction side LWA * at 100 / 75 / 50% nominal air volume flow Sound pressure level LpA , 3 m away from the device * at 100 / 75 / 50% nominal air volume flow Corresponding estimated living space for exchange rate 0.5 1/h, 2.5m ceiling Max. Heat extraction per year at brine inlet temperature 0 ° C, Brine flow 1 m³ / h, air flow 1833 m³ / h Heat recovery rate (brine inlet temperature 7 ° C / 0 ° C)...
Open the catalog to page 8AWN-Top cover opened
Open the catalog to page 9Exhaust air heat recovery module (ventilation unit and heat exchanger) AWN DV-A70 Basic 101 Set up Sound power level Housing radiation LWA* at 100 / 75 / 50% nominal air flow rate Sound power level suction side LWA * at 100 / 75 / 50% nominal air volume flow Sound pressure level LpA , 3 m away from the device * at 100 / 75 / 50% nominal air volume flow Corresponding estimated living space for exchange rate 0.5 1/h, 2.5m ceiling Max. Heat extraction per year at brine inlet temperature 0 ° C, Brine flow 1 m³ / h, air flow 1833 m³ / h Heat recovery rate (brine inlet temperature 7 ° C / 0 ° C)...
Open the catalog to page 10AWN-Top cover opened
Open the catalog to page 11AWN RV-A40 BASIC 100 / 101 Exhaust air heat recovery module (ventilation unit and heat exchanger) Set up Energetic data Corresponding estimated living space for exchange rate 0.5 1/h, 2.5m ceiling Sound power level Housing radiation LWA* at 100 / 75 / 50% nominal air flow rate Sound pressure level LpA , 3m away from the device * at 100 / 75 / 50% nominal air volume flow Max. Heat extraction per year at brine inlet temperature 0 ° C, Brine flow 1 m³ / h, air flow 1833 m³ / h Heat recovery rate (brine inlet temperature 7 ° C / 0 ° C) according to DIN EN 13141-7 Features Sound pressure level...
Open the catalog to page 12AWN RV-A50 BASIC 100 / 101 Exhaust air heat recovery module (ventilation unit and heat exchanger) Set up Energetic data Corresponding estimated living space for exchange rate 0.5 1/h, 2.5m ceiling Sound power level Housing radiation LWA* at 100 / 75 / 50% nominal air flow rate Sound pressure level LpA , 3m away from the device * at 100 / 75 / 50% nominal air volume flow Max. Heat extraction per year at brine inlet temperature 0 ° C, Brine flow 1 m³ / h, air flow 1833 m³ / h Heat recovery rate (brine inlet temperature 7 ° C / 0 ° C) according to DIN EN 13141-7 Features Sound pressure level...
Open the catalog to page 14FLY696_AWN_BASIC_GB – Copyright Aereco – Images: Aereco – All data and pictures in this document are non contractual and are subject to change without prior notice.
Open the catalog to page 16All Aereco Ventilation Limited catalogs and technical brochures
-
BXC-EF
2 Pages
-
BXC-EC
2 Pages
-
BXC-EG
2 Pages
-
V4A PREMIUM
2 Pages
-
V2A
2 Pages
-
BXC
2 Pages
-
GBP
2 Pages
-
G2H
2 Pages
-
S-PRE/Day-Night/T Modbus
9 Pages
-
VCZ
4 Pages
-
AWN ECO+
12 Pages
-
AWN CONNECT
20 Pages
-
EAH²
2 Pages
-
EHT
2 Pages
-
EHA²
2 Pages
-
EMM²
2 Pages
-
VCZ - VTZ Catalogue
20 Pages