Introduction
This user manual for the Aduro 3 wood burning stove provides essential guidelines for installation, operation, and maintenance to ensure optimal performance and safety.
1.0 General Information
1.1 Compliance
The Aduro 3 stove complies with EN 13240 and NS 3058 standards, approved for use in Europe, and carries the Nordic Swan Eco-label for environmental compliance.
1.2 Technical Data
Key specifications include a nominal power of 5 kW, chimney draught of 12 Pa, maximum wood combustion of 2.4 kg/hour, and a flue outlet diameter of 150 mm. The stove weighs between 88-95 kg depending on the model.
1.3 Transportation
Transport the stove upright and secure loose parts if laid flat.
1.4 Serial Number
Record the serial number for warranty and inquiries.
2.0 Installation
Consult a chimney sweep before installation and ensure compliance with local and European standards. The stove must be inspected and approved before use.
2.1 Position and Distance Requirements
Maintain specific distances from flammable materials: 20 cm from the rear, 30 cm from the sides, and 85 cm from the front. An insulated pipe can reduce the rear distance to 10 cm.
2.2 Connection to a Brick Chimney
Use a curved flue pipe for connection, ensuring proper sealing and protrusion into the chimney.
3.0 Operation
3.1 Safety Information
Handle with caution as the stove becomes hot. Avoid combustible fluids nearby and ensure the ash drawer is cool before emptying.
3.2 Recommended Fuels
Use split hardwood stored outdoors for at least a year. Avoid burning varnished or treated wood.
3.3 Lighting a Fire
Open primary and secondary air intakes, place logs and firelighters, and adjust air intake as needed.
3.4 First Use
Expect smoke and odors as paint hardens. Ensure ventilation and avoid intense fires initially.
3.5 Usage
Intended for intermittent combustion. Regulate heat with fuel size and quantity.
3.6 Secondary Damper
Keep open for efficient combustion. Adjust airflow with the Aduro Key.
3.7 Primary Damper
Open when adding logs to enhance combustion.
3.8 Aduro-tronic
A mechanical system for optimal combustion without electricity. Adjust settings based on wood size and moisture.
3.9 Ventilation
Ensure adequate fresh air supply to prevent smoke leakage and maintain combustion efficiency.
Chimney Specifications and Maintenance
The ideal chimney draught is between 0.10 to 0.14 mbar. If natural draught is insufficient, a smoke extractor or damper may be necessary. Solutions for inadequate draught include extending the fire lighting phase to warm the chimney.
Stove Maintenance and Cleaning
Regular maintenance is crucial. Replace gaskets when worn, clean soot from glass with a damp cloth and ash, and replace combustion chamber tiles when cracks exceed 0.5 cm. Empty ash regularly, leaving a layer for insulation. Clean the stove's surface with a soft cloth, avoiding solvents. Internal cleaning should occur annually or more frequently, and surface scratches can be repaired with Senotherm® paint.
Spare Parts and Alterations
Use only original spare parts and avoid unauthorized alterations to maintain compliance.
Accessories
Available accessories include companion sets, firewood buckets, and floor plates.
Product Liability and Warranty
The product liability lasts two years from purchase, covering manufacturing defects but not wear parts. An extended warranty up to five years is available through online registration within one month of purchase.
Additional Information
For further details, users are directed to visit the manufacturer's website.
See more

Catalog excerpts

Aduro 3-1

Aduro 3 User Manual Ecolabel - Sintef 110-0234 - EN 13240 www.aduro.dk Version 2

 Open the catalog to page 1
Aduro 3-2

Good luck with your new wood burning stove! In order to get the best possible pleasure and benefit from your new Aduro wood burning stove, it is important that you read this User Manual thoroughly before you install your wood burning stove and start to use it. 1.0 General 1.1 Compliance Aduro 3 complies with the EN 13240 European standards, as well as the NS 3058 Norwegian standard and is thereby approved for installation and use in Europe. The product documentation for Norway has Sintef number 110-0234 and can be downloaded from our website at www.aduro.no or from www.nbl.sintef.no. At the same...

 Open the catalog to page 2
Aduro 3-3

2.0 Installation of the wood burning stove You are welcome to install your wood burning stove yourself - but we strongly recommend that you consult your chimney sweep before you begin the installation. Your dealer can also provide you with installation advice. It is important to ensure that all local rules and regulations, including ones relating to national and European standards, are complied with when installing this device. Please note: You may not begin to use the wood burning stove until it has been inspected and approved by your local chimney sweep. 2.1 Position of the stove/distance requirements...

 Open the catalog to page 3
Aduro 3-4

between the flue pipe and the pipe sleeve to seal the joints. The flue pipe should protrude 5-10 cm into the pipe sleeve, but must not block the opening in the chimney (see the illustration below). The wood burning stove can be connected to a chimney to which other heat sources are connected. 3.0 Lighting a fire in the wood burning stove 3.1 Important safety information The wood burning stove will become warm during use and therefore it should be treated with all necessary caution. Օ Never keep easily combustible fluids such as petrol in the vicinity of the wood burning stove - and never use...

 Open the catalog to page 4
Aduro 3-5

the fire burning evenly. The secondary air intake is closed when the damper is pushed all the way to the right and open when the damper is pushed to the left. To open the primary air intake the damper should be pulled out. The illustration below shows the stove seen from the front with the dampers indicated. 2) Place a log of wood crosswise in the combustion chamber and put 2 firelighters close to the log. Light the firelighters and quickly put a new log close to the firelighters and several small logs at an angle above it. Air must be able to reach the firelighters, but the logs should be touching...

 Open the catalog to page 5
Aduro 3-6

enhanced effect, you can add more logs. The nominal heat output is reached by burning approx. 2 kg per hour. 3.6 Secondary damper The secondary damper on the door should always be open while the wood burning stove is in use. This damper allows you to adjust the wood burning stove to the chimney draft and the heat output you require. In normal circumstances, the wood burning stove should be working with this damper open between 60 % and 100 %. You should never close the air intake so far that the flames are extinguished. There should always be visible flames in order to achieve clean and efficient...

 Open the catalog to page 6
Aduro 3-7

automatic is activated by pulling the primary damper out each time fresh wood is put in the stove. The automatic closes then the primary air gradually. Regulation of the Aduro-tronic control The control is pre-set to allow primary air intake for the first 5 minutes. This setting has been used during testing at the Danish Technological Institute using 'standard' sized logs and with optimum moisture content of 17-20%. Standard size logs are approx. 30 cm long and 10 x 10 cm in thickness. A standard chimney was also used for testing. In practice, such circumstances can differ, which is why the Aduro-tronic...

 Open the catalog to page 7
Aduro 3-8

stove is used. You can change the tiles yourself. They are available as a ready-to-use set. You can also buy one-piece tiles that you can cut to the size of the worn plates yourself. Please consult your dealer. Ash Empty the ash drawer before it becomes completely full. Always leave a layer of ash on the bottom of the stove, as this insulates the combustion chamber and makes lighting a fire easier. Cleaning the wood burning stove The stove's surface is treated with a heat-resistant Senotherm® paint, which will stay at its best just by being vacuumed with a small, soft mouthpiece or dusted with...

 Open the catalog to page 8
Aduro 3-9

Glass and steel floor plates Օ Flue pipes 8.0 Product liability and warranty In accordance with the Danish Sale of Goods Act, product liability will exist for two years from the date of purchase of the wood burning stove. The dated receipt will be sufficient proof. Product liability will not cover damage caused by incorrect installation and use of the wood burning stove. Likewise, product liability will not cover loose parts and wear parts (fireproof tiles, glass, gaskets, rails, cast iron grate and control), as they are worn by ordinary use. These parts can be purchased as spare parts. 8.1 Free...

 Open the catalog to page 9

All ADURO A/S catalogs and technical brochures

  1. Aduro Hybrid

    5  Pages

  2. Aduro_15__15.1

    94  Pages

  3. Aduro_13

    88  Pages

  4. Aduro_12

    100  Pages

  5. Aduro_9

    87  Pages

  6. Catalogue

    20  Pages

Archived catalogs

  1. Aduro 9-4

    43  Pages

  2. Aduro 9-2

    42  Pages

  3. Aduro 8

    9  Pages

  4. Aduro 7

    8  Pages

  5. Gas Grill

    6  Pages

  6. Aduro 11

    38  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.