Introduction
The Aduro 13 wood-burning stove is a user-friendly appliance compliant with European standard EN13240 and Norwegian standard NS3058. It is approved for use across Europe and carries the Nordic Swan Ecolabel, indicating its environmentally friendly production.
Warranty
The stove includes a two-year warranty, extendable to five years with online registration within five months of purchase.
Technical Specifications
The Aduro 13 features a nominal output of 5.0 kW, a smoke outlet diameter of 15 cm, and dimensions of 87 x 48 x 34.5 cm. It weighs 80 kg and is constructed from sheet iron. Designed for wood and wood briquettes, it accommodates logs up to 35 cm in length. The stove offers convection heating, multiple air supplies, a glass cleaning system, and an ash drawer. Its efficiency is 80.5%, with an energy efficiency index of 110.2 and a class of A+.
Installation
While users can install the stove themselves, consulting a chimney sweep is recommended. Compliance with local, national, and European regulations is mandatory. In Norway, installation must be reported to local authorities, and safety inspections are required.
Placement and Clearance Requirements
Clearance requirements depend on surrounding materials. Specific distances must be maintained for combustible materials, while a 5-10 cm gap is recommended for non-combustible materials for cleaning and optimal convection.
Operation and Safety
The stove becomes hot during use, necessitating caution. Flammable liquids should not be stored nearby, and the ash drawer should not be emptied while hot. The door should remain closed during operation, except during initial lighting.
Air Control
The stove features primary, secondary, and tertiary air controls. The secondary air control should remain open during operation to ensure efficient combustion and prevent soot on the glass.
Aduro-tronic System
This system automatically regulates combustion air for optimal burning, reducing wood consumption by up to 40%. It requires manual activation during lighting and refueling.
Ventilation
Adequate ventilation is necessary for optimal stove performance. In tightly sealed homes, additional air supply may be needed to prevent smoke issues.
First Use
Initial use may produce smoke and odors as the stove's paint cures. Adequate ventilation is recommended during this period.
Lighting Instructions
Proper lighting is crucial for efficient combustion. The manual provides detailed steps for lighting and maintaining the fire.
Specifications and Features
The Aduro wood-burning stove offers efficient combustion and can reduce firewood usage by up to 40%. It includes an Aduro-tronic control system for optimal air regulation during lighting and stoking.
Operating Instructions
Lighting the Stove: Initially, the primary damper should be fully open to light the fire. Once the stove is warm, the Aduro-tronic can be set to automatic. The door can be left ajar during the first few minutes of lighting.
Stoking: When adding fresh wood, the primary air is automatically regulated to ensure optimal combustion. The Aduro-tronic control is preset to close the primary air intake within 6 minutes but can be adjusted based on specific conditions.
Ventilation and Air Supply
For optimal efficiency, ensure sufficient fresh air supply to the room. In well-insulated houses, additional ventilation might be necessary to prevent smoke leakage.
Usage Recommendations
The stove is designed for intermittent combustion, allowing logs to burn down to embers before adding more. Optimal combustion is achieved with two logs and a heat output of approximately 1.5 kg per hour.
First-Time Use
Initial use may produce smoke and odors due to paint hardening. Ensure good ventilation and avoid intense fires initially to allow the stove to expand slowly.
Fuel Recommendations
Use dry wood with a moisture content not exceeding 18%. Avoid burning varnished wood, chipboard, or other waste materials.
Chimney Requirements
Optimal combustion requires a chimney draft of 10-14 Pa. Draft issues can be addressed by ensuring proper chimney height and insulation.
Maintenance and Cleaning
Regular maintenance includes checking gaskets, cleaning the glass, and ensuring the combustion chamber is in good condition. Use only original spare parts and avoid unauthorized alterations.
Accessories and Warranty
A range of accessories is available, including firewood baskets and cleaning pads. The stove comes with a two-year warranty, extendable to five years with online registration.
General Information
  • Certifications: The Aduro 13 stove complies with European standard EN13240 and Norwegian standard NS3058, making it approved for installation and use in Europe. It also holds the Nordic Swan Ecolabel, ensuring it is environmentally friendly.
  • Technical Data: The stove has a nominal output of 5.0 kW, with dimensions of 87 x 48 x 34.5 cm, and weighs 80 kg. It uses wood and wood briquettes as fuel, with a maximum wood length of 35 cm. The efficiency is 80.5%, with an energy efficiency class of A+.
  • Transport: When transporting the stove, it should ideally remain upright. If laid down, remove loose parts like the cast iron grate and fireproof stones.
Installation
  • Placement: The stove must be placed with specific distance requirements from combustible materials, such as 21 cm behind and 46 cm to the side. If placed on a combustible surface, a non-combustible base is required.
  • Pipe Connection: Aduro 13 comes with a top smoke outlet, but can be adjusted for a rear outlet. Ensure the floor can support the stove's weight.
  • Chimney Connection: The stove can connect to a masonry chimney using the rear outlet or a bent pipe via the top connection.
Operation
  • Safety Instructions: The stove becomes hot during use, so handle with care. Never store flammable liquids nearby, and ensure the door is closed during operation.
  • Air Vents: The stove has primary, secondary, and tertiary air vents to control combustion. The secondary vent should always be open during use.
  • Aduro-tronic: This automatic function regulates combustion air for optimal burning, reducing fuel consumption by up to 40%.
  • Ventilation: Adequate air supply is crucial for optimal stove performance. In tightly sealed homes, additional ventilation may be necessary.
First Use and Maintenance
  • First Firing: Initial use may produce smoke and odor as the heat-resistant paint cures. Ensure proper ventilation during this time.
  • Lighting the Stove: Proper ignition is essential for efficient combustion. Use dry wood and follow the recommended lighting procedure.
  • Wood Selection: Use well-seasoned wood with a moisture content not exceeding 18%. Avoid burning treated or painted wood, as well as fossil fuels.
Chimney
  • Optimal combustion is achieved with a constant chimney draft.
Wood Stove Operation and Maintenance Guide
Air Valve Operation: The wood stove operates optimally with the air valve open between 60% and 100%. It should never be closed completely to ensure visible flames and efficient combustion. Insufficient air can lead to poor combustion and higher emissions. The air valve also adjusts the automatic glass cleaning system to reduce soot accumulation.
Primary Air Lever: When adding new logs, the primary air lever should be open until the fire is well established. To prevent ash from falling when opening the door, open the primary air lever for about 1 minute before opening the door.
Aduro-tronic System: This patented mechanical system regulates combustion automatically without electricity, saving up to 40% of wood. It requires initial manual adjustment but then operates automatically to optimize combustion.
Ventilation and Fresh Air Supply: Adequate air supply is crucial for optimal stove operation. In airtight homes, opening a window or installing an air vent may be necessary to prevent smoke and ensure proper combustion.
Fueling the Fire: The stove is designed for intermittent combustion, requiring refueling only after a layer of embers has formed. Optimal combustion is achieved with logs of approximately 1.5 kg per hour.
First Ignition: Initial use may produce smoke and odors due to the curing of heat-resistant paint. Ensure proper ventilation and avoid intense fires during the first few uses to allow the stove structure to adjust.
Wood Type: Use hardwood logs stored outdoors for at least a year with moisture content not exceeding 18%. Avoid burning treated wood, paper, or waste materials to prevent environmental harm and stove damage.
Chimney Requirements: Optimal draft is between 10 and 14 Pa, or 18 to 25 Pa for natural draft. Factors like external temperature and wind can affect draft, and the chimney should extend 40 cm above the roof ridge.
Maintenance: Regularly inspect and replace worn vermiculites, clean glass with a damp cloth and ashes, and ensure seals are intact. Empty the ash pan before it is full, leaving a layer of ash for insulation.
Chimney Specifications and Recommendations
The document outlines the optimal conditions for chimney draft, which should be between 10-14 Pascal (Pa) immediately after the stove exit and 18-25 Pa under natural conditions. Factors such as external temperature, wind, and nearby buildings can affect the draft. A minimum draft of 5 Pa is recommended during ignition, increasing to 18-25 Pa for optimal combustion.
Chimney Draft Issues
Problems with draft may arise if the chimney is too short, has leaks, or is poorly insulated. It is advised to check the draft both during ignition and when the system is hot. If issues persist, using more fire starters or an optimizer like Aduro DraftOptimizer is recommended.
Smoke Emission
Smoke may escape from the stove if the chimney is cold or due to changing weather conditions. It is advised to warm up the system with small wood pieces if the chimney has been unused for a long time.
Wood Stove Maintenance
Regular maintenance includes checking and replacing worn gaskets, inspecting the combustion chamber lining, and cleaning the glass with specific products. The stove should be maintained only when cold, and the ash drawer should be emptied regularly.
Cleaning and Repairs
The stove's surface, treated with heat-resistant paint, should be cleaned with a vacuum or soft cloth. The interior and chimney should be cleaned at least annually. Surface scratches can be repaired with heat-resistant paint available from authorized dealers.
Spare Parts and Unauthorized Modifications
Only original spare parts should be used, and unauthorized modifications are prohibited as they may void the stove's specifications.
Accessories
Aduro offers a range of accessories including firelighters, cleaning sponges, and various stove-related products.
Warranty and Claims
The document outlines a two-year warranty period under Danish law, excluding wear-and-tear parts and damages from improper installation or use. Proof of purchase is required for claims.
See more

Catalog excerpts

Aduro_13-1

Aduro 13 Ecolabel - EN13240 aduro.dk / aduro.no / adurofire.de / adurofire.com adurofire.se / aduro.fr / aduro.es / aduro.it

 Open the catalog to page 1
Aduro_13-2

Tillykke med din nye Aduro brændeovn! For at få mest mulig glæde og nytte af din nye Aduro brændeovn er det vigtigt, at du læser betjeningsvejledningen grundigt, inden brændeovnen installeres og tages i brug. Har du brug for yderligere informationer, kan du læse meget mere på www.aduro.dk / www.aduro.no. 5 års garanti – Ved gratis onlineregistrering Du har mulighed for at udvide garantien på din brændeovn fra to til fem år. Registrer den på www.aduro.dk/garanti/ / www.aduro.no/garanti/ senest fem måneder efter køb, og du får fem års gratis garanti. Produktionsnummer På brændeovnen er der angivet...

 Open the catalog to page 2
Aduro_13-3

1.1 Godkendelser Aduro 13 opfylder den europ^iske standard EN13240 samt Norsk standard NS3058 og er dermed godkendt til montering og brug i Europa. Produktionen er samtidig underlagt ekstern kvalitetskontrol. Aduro 13 b^rer desuden det nordiske milj0m«rke Svanem^rket, som er din garanti for, at brandeovnen er blandt de mest milj0rigtige pa markedet og produceres pa en milj0m«ssig forsvarlig made. DoP (Declaration of Performance/Ydeevnedeklaration) kan downloades pa www.aduro.dk/download / www.aduro.no/download. 1.3 Hjemtransport Ved hjemtransport af brandeovnen skal den helst sta lodret op. Hvis...

 Open the catalog to page 3
Aduro_13-4

Du ma gerne selv installere din brandeovn - vi anbefaler dog at tage din skorstensfejer med pa rad. Det er vigtigt at v^re opm^rksom pa, at alle lokale forordninger og regler, inklusive dem, der henviser til nationale og europ^iske standarder, skal overholdes ved installation af brandeovnen. Du kan ogsa s0ge rad om installation hos din forhandler. Husk, at det er dig, der har ansvaret for, at g^ldende regler overholdes. Brsndeovnen ma forst tages i brug, nar den er godkendt af den lokale skorstensfejer. SPESIELT FOR NORGE: Installasjon av nye ildsteder meldes til lokale bygningsmyndigheter. Huseier...

 Open the catalog to page 4
Aduro_13-5

SPESIELT FOR NORGE: Ved plassering mot forskriftsmessig brannmur skal avstanden minimum være 5 cm bak og 25 cm til siden (se illustrasjon): Står brændeovnen op ad en murstensvæg eller andre ikke-brændbare materialer, er der ingen minimumskrav til afstand. Af hensyn til rengøringen og for den bedste udnyttelse af konvektionsluften anbefaler vi dog at holde cirka 5-10 cm afstand til væggen. Ønsker du at placere din brændeovn på et brændbart materiale som f.eks. trægulv eller gulvtæppe, er det nødvendigt med et ikke-brændbart underlag. Gulvpladens størrelse afhænger af brændeovnens størrelse og...

 Open the catalog to page 5
Aduro_13-6

SPESIELT FOR NORGE: I Norge er det ikke et krav om at gulvplaten skal dekke 15 cm til hver side. Vi anbefaler imidlertid at gulvplaten dekker minimum 5-10 cm til siden. Brændeovnen skal installeres på et gulv med tilstrækkelig bæreevne. Hvis den eksisterende konstruktion ikke opfylder denne forudsætning, skal der foretages passende foranstaltninger (fx belastningsfordelende plade) for at opnå dette. 2.2 Rørtilslutning Aduro 13 er fra fabrikken monteret med røgafgang i toppen. Ønskes røgafgang bagud ”knækkes” de runde dækplader af øverst bag på ovnen. Røgstudsen (fra topafgangen) ombyttes med...

 Open the catalog to page 6
Aduro_13-7

3. Fyring i brændeovnen Vigtige sikkerhedsoplysninger • • • • Brændeovnen bliver varm under brug, og der skal derfor udvises fornøden forsigtighed. Opbevar aldrig letantændelige væsker som benzin i nærheden af brændeovnen. Anvend aldrig letantændelige væsker til at antænde brændet i brændeovnen. Tøm aldrig askeskuffen, når brændeovnen er varm. Der kan ligge gløder i askeskuffen i op til 24 timer efter, at ilden er gået ud. Vent derfor med at tømme askeskuffen til du er sikker på, at der ingen gløder er i asken. Lågen skal være lukket, mens brændeovnen er i brug. Kun de første minutter under optænding...

 Open the catalog to page 7
Aduro_13-8

Hvis du overfyrer brændeovnen og afbrænder mere end ca. 3,5 kg træ i timen, er der risiko for, at lakken på ovnen misfarves og senere falder af. Ovnen kan senere efterlakeres, men det er ikke omfattet af producentens garanti. Ligeledes er andre skader på ovnen, der skyldes overfyring, ikke dækket af garantien. 3.2 Aduro-tronic Den patentanmeldte automatik Aduro-tronic er en manuel betjent mekanisk opstartsanordning, der virker uden tilslutning af strøm, og som automatisk regulerer forbrændingsluften og sikrer optimal forbrænding. Du skal således kun tænke på at lægge tørt træ i ovnen og aktivere...

 Open the catalog to page 8
Aduro_13-9

3.3 Ventilation/frisklufttilførsel For at brændeovnen virker optimalt, skal der tilføres luft til forbrændingen. Derfor skal der kunne komme tilstrækkeligt med luft ind i rummet, hvor brændeovnen står. Tætte huse, kraftige emhætter og ventilationsanlæg kan skabe undertryk omkring brændeovnen, hvilket giver røggener og dårlig forbrænding. I disse tilfælde vil det være nødvendigt at åbne et vindue for at tilføre luft til forbrændingen og udligne undertrykket. Alternativt kan du anbringe en luftrist i det rum, hvor brændeovnen står. Den luftmængde, der bruges til forbrændingen, er ca. 25 m 3/h....

 Open the catalog to page 9
Aduro_13-10

3.6 Korrekt optænding i brændeovnen Optændingen er meget afgørende for en hurtig og effektiv start på forbrændingen. 1. Åbn for primærspjældet nederst under lågen og sekundærspjældet øverst bag lågen. Nedenstående illustration viser brændeovnen set fra fronten med angivelse af spjældene. 2. Læg et stykke kløvet træ på tværs i brændkammeret og placer to optændingsprodukter op ad træet. Tænd produkterne og læg hurtigt et nyt stykke kløvet træ tæt op ad produkterne samt et par små stykker træ på tværs ovenpå. Der skal kunne komme luft til optændingsprodukterne samtidig med, at træstykkerne skal...

 Open the catalog to page 10

All ADURO A/S catalogs and technical brochures

  1. Aduro Hybrid

    5  Pages

  2. Aduro_15__15.1

    94  Pages

  3. Aduro_12

    100  Pages

  4. Aduro_9

    87  Pages

  5. Catalogue

    20  Pages

Archived catalogs

  1. Aduro 9-4

    43  Pages

  2. Aduro 9-2

    42  Pages

  3. Aduro 8

    9  Pages

  4. Aduro 7

    8  Pages

  5. Aduro 3

    9  Pages

  6. Gas Grill

    6  Pages

  7. Aduro 11

    38  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.