Introduction
Congratulations on your new Aduro wood stove! To maximize its benefits, it is crucial to read the user manual thoroughly before installation and use. For additional information, visit the Aduro websites.
Warranty
You can extend the warranty from two to five years by registering online within five months of purchase.
General Information
  • Compliance: The Aduro 1.1 models comply with European standard EN13240 and Norwegian standard NS3058, ensuring they are approved for installation and use in Europe. They also carry the Nordic Swan Ecolabel, indicating environmentally friendly production.
  • Technical Specifications: Key specifications include a nominal output of 6.0 kW, a smoke outlet diameter of 15 cm, and a weight of 95 kg (113 kg for SK and SK Limestone models). The stove supports wood and wood briquettes with a maximum log length of 36 cm and has an efficiency of 81.2%.
  • Transportation: During transport, the stove should ideally remain upright. If laid down, remove loose parts from the combustion chamber.
Installation
  • Mounting Stone Cladding: Follow specific instructions to avoid damage when mounting stone cladding on the Aduro 1.1SK models.
  • Stove Installation: While self-installation is allowed, consulting a chimney sweep is recommended. Compliance with local regulations and standards is mandatory.
  • Placement and Distance Requirements: Distance requirements vary based on the materials surrounding the stove. Non-combustible surfaces have no minimum distance requirements, but a 5-10 cm gap is recommended for cleaning and airflow.
  • Pipe Connection: The stove is factory-fitted with a top smoke outlet. For a rear outlet, adjustments are necessary. Ensure compliance with building regulations regarding pipe installation.
Operation
  • Using the Stove: Important safety information includes keeping flammable liquids away and ensuring the door is closed during use.
  • Air Vents: The stove features primary, secondary, and tertiary air vents for combustion control. The secondary vent should remain open during operation.
  • Aduro-tronic: This automatic system optimizes combustion by regulating air intake, reducing wood consumption by up to 40%.
  • Ventilation: Adequate air supply is necessary for optimal stove performance. In tightly sealed homes, additional ventilation may be required.
  • Firing the Stove: The stove is designed for intermittent combustion, meaning each load should burn down to embers before refueling. Optimal combustion is achieved with two pieces of wood, with adjustments made for desired heat output.
Installation and Compliance
Before installing a wood stove, it is recommended to contact the local chimney sweep to ensure compliance with local building regulations and authority requirements. The stove must be inspected and approved by the chimney sweep before use. Specific legal requirements can be found in the respective state building codes and fire regulations.
Positioning and Safety Distances
The stove should be positioned according to local regulations, maintaining minimum distances from combustible materials. For example, a distance of 17 cm is required behind the stove with an insulated flue pipe, and 45 cm to the side. The floor in front of the stove must be non-combustible, extending at least 50 cm in front and 30 cm on each side of the firebox opening.
Flue Connection
The Aduro stove is prepared for top flue connection but can be adapted for rear connection. The flue pipe must have a CE certification and maintain the required distance from combustible materials.
Chimney Connection
When connecting to a masonry chimney, a rear flue outlet or a bent flue pipe should be used. The stove must be placed on a floor with sufficient load-bearing capacity.
Heating Operation
Important safety warnings include not storing flammable liquids near the stove and ensuring the ash pan is emptied only when cold. The stove should not be operated with the firebox door open.
Air Regulation
The stove features primary, secondary, and tertiary air controls. The secondary air slider should always be open during operation to ensure efficient combustion and prevent soot on the glass.
Aduro-Tronic System
This manual mechanical start-up system regulates combustion air automatically, potentially saving up to 40% of wood usage. It is important not to overload the stove to prevent damage.
First Use and Lighting
During the first use, the stove should be heated gradually to allow materials to adjust. Proper ventilation is necessary to manage smoke and odors from the curing paint.
Fuel Recommendations
The stove is suitable for wood and wood briquettes. Only dry, untreated wood with a moisture content of no more than 18% should be used, as per environmental regulations.
Installation Requirements
The wood burning stove must be placed on a non-flammable base, extending at least 30 cm in front and 15 cm on each side of the combustion chamber. The floor must have adequate load-bearing capacity, and if not, adaptations like a load-distributing plate are necessary.
Pipe Connection
The Aduro stove comes with a top-mounted flue outlet, but it can be adjusted for a rear outlet. A flue pipe with a 150 mm internal diameter is recommended. Compliance with local regulations, including CE marking, is essential.
Chimney Connection
For brick chimneys, use the rear outlet or a curved flue pipe. Ensure the flue pipe does not block the chimney opening and use a gasket to seal joints.
Lighting the Stove
Exercise caution as the stove becomes hot. Avoid using combustible fluids for lighting. Keep the door closed during use, and in case of a chimney fire, close all dampers and contact fire services.
Damper Operation
The stove has primary, secondary, and tertiary dampers. The secondary damper should remain open during use to adjust heat output and prevent soot on the glass. The primary damper aids in lighting and adding logs.
Aduro-tronic Control
This manual device regulates combustion without electricity, optimizing wood usage by up to 40%. It requires initial manual adjustment but then operates automatically.
Ventilation
Adequate fresh air is necessary for combustion. In well-insulated homes, additional ventilation may be required to prevent smoke leakage.
First Use
Initial use may produce smoke and odors due to paint hardening. Ensure good ventilation and avoid intense fires initially.
Recommended Fuels
Use dry wood with a moisture content below 18%. Avoid burning varnished wood, chipboard, or waste materials.
Chimney Requirements
Optimal draft is 10-14 Pa with a smoke exhauster, or 18-25 Pa naturally. Draft issues may require chimney adjustments or a smoke exhauster.
Chimney and Ignition: It is important to ensure that the chimney is warm to prevent smoke leaks during ignition. If the chimney is cold, use wood sticks to heat it and eliminate cold plugs.
Maintenance and Cleaning: Regular inspection and replacement of worn gaskets are necessary. Fireproof tiles in the combustion chamber should be replaced if cracks exceed 0.5 cm. Soot on the glass can be cleaned with a damp cloth dipped in cold ash or using special cleaning pads. The stove should be cleaned when cold, and the ashpan should be emptied regularly. The stove's surface can be maintained with a soft cloth and should not be cleaned with water to prevent rust.
Spare Parts and Alterations: Only original spare parts should be used, and unauthorized alterations are prohibited as they may void the stove's compliance with specifications.
Accessories: A range of accessories is available, including companion sets, firewood baskets, and cleaning pads.
Right of Complaint: A two-year right of complaint is provided under the Danish Sale of Goods Act, excluding damages from incorrect installation or use. An extended five-year warranty is available with online registration.
Certifications and Technical Data: The stove meets European and Norwegian standards and is environmentally certified. Technical specifications include a nominal output of 6.0 kW, efficiency of 81.2%, and a maximum wood length of 36 cm.
Installation: The stove can be self-installed, but guidance from a chimney sweep is recommended. Compliance with national and European regulations is required. The stove must be approved by a fire authority before use.
Operation: The stove becomes hot during use and should be handled with care. Various air vents control combustion, and proper operation ensures efficient burning and minimal emissions.
General Information
  • Compliance: The Aduro 1.1 / 1.1SK / 1.1SK Limestone stove complies with European standards EN13240 and Norwegian standard NS3058, approved for installation and use in Europe. It carries the Nordic Ecolabel, ensuring adherence to strict environmental standards.
  • Technical Specifications: The stove has a nominal power of 6.0 kW, a flue diameter of Ø15 cm, and dimensions of 101.5 x 50 x 45 cm (104.5 x 50 x 45 cm for SK and SK Limestone). It weighs 95 kg (113 kg for SK and SK Limestone) and is made of steel. It uses wood and wood briquettes as fuel, with a maximum log length of 36 cm. The efficiency is 81.2%, with an energy efficiency index of 108.7 and an A+ energy class.
  • Transport: The stove should be transported upright. If transported lying down, remove the ash pan and any loose parts.
Installation of Soapstone and White Stone
  • Stones should be installed only when the stove is in its final position. Use the provided dowels and metal supports for installation.
Wood Stove Installation
  • Placement: If placed against a non-flammable wall, no minimum distance is required, but a 5-10 cm gap is recommended for cleaning and convection air use.
  • Flue Connection: The flue outlet is on top but can be moved to the rear. Ensure compliance with building regulations and safety distances from flammable materials.
Operation and Safety
  • Safety Precautions: The stove remains hot during use. Do not use flammable liquids to start the fire, and keep the door closed during operation.
  • Air Control: The stove has primary, secondary, and tertiary air controls. The secondary air control should remain open during operation for optimal combustion.
  • Aduro-tronic System: This mechanical system regulates combustion automatically, saving up to 40% of wood.
Ventilation
  • Ensure adequate air supply for combustion. In airtight homes, additional ventilation may be necessary.
Specifications:
The Aduro wood stove models 1.1, 1.1SK, and 1.1SK Limestone comply with European Standard EN13240 and Norwegian Standard NS3058, ensuring they are certified for use in Europe. They also hold the Nordic Swan Eco-label, indicating adherence to strict environmental standards. The nominal power is 6.0 kW, with a smoke outlet diameter of 15 cm, available in both top and rear configurations. The dimensions vary slightly between models, with the SK and SK Limestone versions being slightly taller and heavier.
Combustion and Fuel:
Optimal combustion is achieved by regulating the heat through the amount of fuel. Smaller logs burn more intensely due to a larger surface area. The ideal temperature is reached by burning approximately 1.5 kg of wood per hour. It is recommended to use hardwood logs stored outdoors for at least a year, with moisture content not exceeding 18%. Logs should be split to about 10 cm in diameter and 36 cm in length.
First Ignition:
During initial use, smoke and odors may emanate from the stove due to the curing of heat-resistant paint. Ensure proper ventilation and avoid intense fires during the first few uses to allow the stove structure to adjust. Use dry wood of appropriate size for optimal combustion.
Lighting Procedure:
Open the primary and secondary air inlets, place a log in the combustion chamber, and use fire starters to ignite. Keep the door slightly open until the glass is too hot to touch, then close it. Adjust the air inlets as needed once the fire is established.
Chimney Requirements:
For optimal combustion, the chimney draft should be between 10 and 14 Pa with an extractor, or 18 to 25 Pa naturally. The chimney should extend 40 cm above the roof ridge to ensure proper draft. If draft issues persist, consider using a smoke extractor like the Aduro DraftOptimizer.
Maintenance:
Regular inspection and replacement of worn gaskets and vermiculites are necessary. Clean the glass with a damp cloth and cold ashes or use specialized cleaning products. The stove's surface can be cleaned with a soft brush or cloth, avoiding water and solvents. The interior and chimney should be cleaned annually by a professional.
Warranty and Claims:
A two-year warranty is provided, extendable to five years upon registration. The warranty does not cover damages from improper installation or use, nor does it cover naturally wearing parts like vermiculites and gaskets.
Accessories:
A range of accessories is available, including fire starters, cleaning sponges, and protective grilles. More information can be found on the Aduro website.
Specifications:
- Convection stove with primary, secondary, and tertiary air inlets.
- Clean glass system and ash drawer.
- Efficiency: 81.2%, Energy efficiency index: 108.7, Energy label: A+.
- Chimney draft: 12 Pa, Maximum fuel consumption: 3.4 kg/h.
- Heating area: 150 m² (optimal insulation), 100 m² (medium insulation), 60 m² (poor insulation).
Transportation:
- Ensure the stove remains upright during transport. If laid down, remove combustion chamber elements and ash drawer.
Installation of Soapstone:
- Follow instructions to avoid damage. Remove metal supports before final placement. Install stones carefully using provided pins and supports.
Wood Stove Installation:
- Consult a chimney technician for installation. Ensure compliance with local, national, and European regulations.
- Maintain safety distances from flammable materials: 17 cm behind, 12 cm with insulated outlet, 45 cm sides, 75 cm above, 30 cm corner, 100 cm to furniture.
- Use a non-flammable base if installing on flammable materials. Ensure the floor can support the stove's weight.
Connection:
- Factory-installed top smoke outlet; rear outlet requires modifications. Ensure compliance with CE regulations for pipes and outlets.
Lighting the Stove:
- Handle with care as the stove heats up. Avoid flammable liquids and ensure the ash drawer is emptied only when cold.
- Keep the door closed during use, slightly open when lighting.
Air Inlets:
- Primary air for lighting, secondary for power regulation, tertiary for burning combustion gases.
- Secondary air should remain open during combustion for clean burning and to prevent soot on the glass.
Aduro-Tronic System:
- Manual ignition system that regulates combustion automatically, saving up to 40% wood.
- Adjust the system with an Allen key for optimal performance based on installation conditions.
Ventilation:
- Ensure adequate air supply for combustion. In small houses, open a window or install a vent if necessary.
Using the Stove:
- Designed for intermittent combustion. Use dry wood of appropriate size for optimal combustion.
- First use may produce smoke and odors as the paint cures. Ensure good ventilation.
Lighting Instructions:
- Open primary and secondary air inlets. Use kindling and fire starters for initial lighting. Keep the door slightly open until the glass is hot, then close it.
Installation Requirements
The stove must be installed on a floor with sufficient load-bearing capacity. If the existing structure does not meet this requirement, appropriate measures such as using a load distribution plate should be taken. Ensure a clearance of at least 30 cm in front and 15 cm on each side of the stove.
Exhaust Connection
The Aduro 1.1 models come with a factory-installed top exhaust. For a rear exhaust setup, swap the top exhaust connector with the rear cover plate. Use a chimney with an internal diameter of 150 mm and comply with CE marking and safety distance regulations from flammable materials.
Connection to Masonry Chimney
For connection to a masonry chimney, use the rear outlet or a curved flue through the top outlet. Drill a hole in the chimney for a wall sleeve, which should be sealed with refractory cement. Ensure the sleeve does not obstruct the flue gases.
Combustion Safety
The stove heats up during use, so caution is necessary. Do not store flammable liquids nearby or use them to ignite the fire. Keep the door closed during operation, except slightly ajar during ignition. In case of a chimney fire, close all air inlets and call the fire department.
Air Regulation
The stove features primary, secondary, and tertiary air controls. Primary air is for ignition, secondary for even burning, and tertiary for exhaust gas combustion. Ensure secondary and tertiary air access during operation.
Aduro-tronic System
This patented system automatically regulates combustion without electricity. It optimizes wood usage and efficiency, potentially saving up to 40% of wood.
Ventilation
Ensure adequate air supply for combustion. In tightly sealed homes, open a window or install an air inlet to balance pressure and prevent smoke issues.
First Use and Ignition
During the first use, expect smoke and odor due to paint curing. Ensure good ventilation and avoid maximum power for the first few uses. Use dry wood with a moisture content below 18% for optimal combustion.
Chimney Requirements
A consistent draft of 10-14 Pascal is ideal, with natural conditions ranging from 18-25 Pa. Factors like external temperature and wind can affect draft. Ensure the chimney is tall enough to maintain good draft.
Chimney Draft Issues
If the chimney is too short or poorly insulated, draft issues may occur. A minimum draft of 5 Pa is recommended during ignition to ensure clean combustion.
Chimney Draft and Smoke Management
It is crucial to maintain a stable chimney draft between 18-25 Pa for optimal combustion. This should be checked when the chimney and stove are hot. In cold conditions, the draft may vary, so it is important to verify it when hot. If issues persist despite a compliant chimney, extending the ignition phase with more fire starters is recommended to heat the chimney adequately. If natural draft is insufficient, a draft optimizer like Aduro DraftOptimizer is suggested.
Wood Stove Maintenance
Regular maintenance is essential for optimal performance. Gaskets should be inspected and replaced if worn. The combustion chamber lining should be replaced if damaged beyond 0.5 cm. The glass can be cleaned with a cloth dipped in cold ashes or using Aduro Easy Clean sponges. All maintenance should be performed when the stove is cold.
Ash and Cleaning
Empty the ash drawer before it fills up, leaving a layer of ash to insulate the combustion chamber. The stove's surface, treated with heat-resistant paint, can be cleaned with a vacuum or soft cloth. Avoid using alcohol or solvents. The interior and chimney should be cleaned at least annually, more frequently if needed, by a chimney sweep or Aduro partner.
Surface Repair
Scratches or wear on the stove's surface can be repaired with heat-resistant paint available from Aduro retailers or online.
Accessories and Warranty
Aduro offers a range of accessories to enhance the user experience. A two-year warranty is provided, covering manufacturing defects but not wear and tear or damages from improper use or installation. Original spare parts are recommended for replacements.
See more

Catalog excerpts

Aduro_1.1__1.1SK__1.1_Limestone-1

Aduro 1.1 / 1.1SK / 1.1SK Limestone Ecolabel - EN13240 aduro.dk / aduro.no / adurofire.de / adurofire.com adurofire.se / aduro.fr / aduro.es / aduro.it

 Open the catalog to page 1
Aduro_1.1__1.1SK__1.1_Limestone-2

Tillykke med din nye Aduro brændeovn! For at få mest mulig glæde og nytte af din nye Aduro brændeovn er det vigtigt, at du læser betjeningsvejledningen grundigt, inden brændeovnen installeres og tages i brug. Har du brug for yderligere informationer, kan du læse meget mere på www.aduro.dk / www.aduro.no. 5 års garanti – Ved gratis onlineregistrering Du har mulighed for at udvide garantien på din brændeovn fra to til fem år. Registrer den på www.aduro.dk/garanti/ / www.aduro.no/garanti/ senest fem måneder efter køb, og du får fem års gratis garanti. Produktionsnummer På brændeovnen er der angivet...

 Open the catalog to page 2
Aduro_1.1__1.1SK__1.1_Limestone-3

1.1 Godkendelser Aduro 1.1 / 1.1SK / 1.1SK Limestone opfylder den europ^iske standard EN13240 samt Norsk standard NS3058 og er dermed godkendt til montering og brug i Europa. Produktionen er samtidig underlagt ekstern kvalitetskontrol. Aduro 1.1 / 1.1SK / 1.1SK Limestone b^rer desuden det nordiske milj0m«rke Svanem^rket, som er din garanti for, at brandeovnen er blandt de mest milj0rigtige pa markedet og produceres pa en milj0m«ssig forsvarlig made. DoP (Declaration of Performance/Ydeevnedeklaration) kan downloades pa www.aduro.dk/download / www.aduro.no/download. 1.3 Hjemtransport Ved hjemtransport...

 Open the catalog to page 3
Aduro_1.1__1.1SK__1.1_Limestone-4

med overskudsemballage, så de løse dele fastholdes. Brug venligst træ fra emballeringen til første optænding. Plasticemballagen smides ud. 2. Montering af fedtsten og limestone Aduro 1.1SK / 1.1SK Limestone er beklædt med sten. For at undgå skader er det vigtigt at følge nedenstående forskrifter: Topstenen ligger på ovnen ved levering og løftes af inden placering. I udtræksskuffen ligger der 6 sider, 12 dyvler samt 6 metalbeslag, som også fjernes inden placering. Beklædningen monteres, når ovnen er placeret, hvor den skal stå. Ved montering af stenene anvendes de medfølgende dyvler samt metalbeslag....

 Open the catalog to page 4
Aduro_1.1__1.1SK__1.1_Limestone-5

SPESIELT FOR NORGE: Installasjon av nye ildsteder meldes til lokale bygningsmyndigheter. Huseier star selv ansvarlig for at alle krav til sikkerhet er ivaretatt pa en forskriftsmessig mate og er forpliktet til a fa installasjonen inspisert og sikkerheten bekreftet av en kvalifisert kontroll0r. Lokalt feiervesen ma informeres dersom installasjonen medf0rer endret feiebehov. Provningsattest Pr0vningsattesten (se side 16) er din sikkerhed for, at brandeovnen opfylder milj0krav og lovbestemmelser i henhold til Brandeovnsbekendtg0relsen, der tradte i kraft 1. juni 2008, og som sidenhen er blevet sk^rpet. Nar...

 Open the catalog to page 5
Aduro_1.1__1.1SK__1.1_Limestone-6

SPESIELT FOR NORGE: Ved plassering mot forskriftsmessig brannmur skal avstanden minimum være 5 cm bak og 22,5 cm til siden (se illustrasjon): Står brændeovnen op ad en murstensvæg eller andre ikke-brændbare materialer, er der ingen minimumskrav til afstand. Af hensyn til rengøringen og for den bedste udnyttelse af konvektionsluften anbefaler vi dog at holde cirka 5-10 cm afstand til væggen. Ønsker du at placere din brændeovn på et brændbart materiale som f.eks. trægulv eller gulvtæppe, er det nødvendigt med et ikke-brændbart underlag. Gulvpladens størrelse afhænger af brændeovnens størrelse og...

 Open the catalog to page 6
Aduro_1.1__1.1SK__1.1_Limestone-7

3.3 Tilslutning til muret skorsten Hvis brændeovnen skal tilsluttes en muret skorsten, benyttes bagudgangen eller et buet røgrør via topafgangen. Efter opmåling laves hul i skorstenen, hvor murbøsningen placeres og mures tæt med pejsemørtel. Herefter placeres brændeovnen, og røgrøret sættes på plads. Læg en tynd pakning mellem røgrør og murbøsning for at tætne samlingerne. Røgrøret skal gå ind i murbøsningen, men må ikke gå ind og blokere for åbningen i skorstenen (se illustration nedenfor): X Læs eventuelt mere om de danske regler i ”Bygningsreglement for småhuse” udgivet af Byggestyrelsen....

 Open the catalog to page 7
Aduro_1.1__1.1SK__1.1_Limestone-8

med dette spjæld mellem 60 % og 100 % åbent. Du må aldrig lukke så langt ned for luftspjældet, at flammerne går ud. Der skal altid være synlige flammer for at opnå en ren og effektiv forbrænding. For lav lufttilførsel kan føre til dårlig forbrænding, høje emissioner samt en dårlig virkningsgrad. Rudeskyllet, der forhindrer sod på frontglasset, styres ligeledes af dette spjæld. Hvis du ønsker at betjene ovnen med laveste ydelse – dvs. omkring 3 kW – skal du lukke sekundærspjældet næsten helt 45 minutter efter indfyring. På dette tidspunkt er der kun få flammer, og ovnen kan brænde rent ved hjælp...

 Open the catalog to page 8
Aduro_1.1__1.1SK__1.1_Limestone-9

4.2.1 Sådan betjenes Aduro-tronic Ved optænding Ved første optænding af brændeovnen skal der tilføres maksimal mængde primærluft for at antænde bålet. Derfor skal primærspjældet holdes ”tvangsåbent”. Dette gøres ved at trække primærspjældet helt ud og dernæst sætte den medfølgende Aduro-nøgle i klemme (se illustration). Når ovnen er varm, og der er skabt et glødelag i bunden af brændkammeret, kan Aduro-tronic sættes i automatikposition, dvs., at Aduro-nøglen fjernes. Alternativt kan du lade lågen stå på klem de første minutter af optændingsfasen (uden nøgle). Ved indfyring Hver gang, der lægges...

 Open the catalog to page 9
Aduro_1.1__1.1SK__1.1_Limestone-10

opnås ved at lægge to stykker træ ind. Ønsker du dog en høj effekt, kan du lægge mere træ på. Den ideelle varmeydelse opnås ved at påfyre ca. 1,5 kg træ pr. time. Det er vigtigt at bruge tørt træ i den rigtige størrelse for at opnå den optimale forbrænding. 4.5 Første optænding Ovnen er pakket i emballage, som kan genbruges. Træet fra emballagen kan saves i mindre stykker og bruges ved de første optændinger. Plast skal dog bortskaffes i henhold til nationale bestemmelser vedr. bortskaffelse af affald. De første gange, brændeovnen anvendes, kan der forekomme røg og lugtgener fra brændeovnen, hvilket...

 Open the catalog to page 10

All ADURO A/S catalogs and technical brochures

  1. Aduro Hybrid

    5  Pages

  2. Aduro_15__15.1

    94  Pages

  3. Aduro_13

    88  Pages

  4. Aduro_12

    100  Pages

  5. Aduro_9

    87  Pages

  6. Catalogue

    20  Pages

Archived catalogs

  1. Aduro 9-4

    43  Pages

  2. Aduro 9-2

    42  Pages

  3. Aduro 8

    9  Pages

  4. Aduro 7

    8  Pages

  5. Aduro 3

    9  Pages

  6. Gas Grill

    6  Pages

  7. Aduro 11

    38  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.