video corpo cad

SMU 2
5Pages

{{requestButtons}}

Catalog excerpts

SMU 2 - 1

BASIC FEATURES – 7 types of three-way valve – With/Without short-circuit – mit/ohne Kurzschluss The SMU mixing unit is designed for controlling the heat-out- Der Mischknoten SMU ist zur Regelung der Wärmeleistung put of water-type heat exchangers. It is used especially for des Wasserwärmetauschers bestimmt. Wird besonders für die controlling standalone water-type air heaters, heaters inbuilt Regelung separater in den Belüftungsgeräten und Luft-schleiern into the ventilation units, heaters in air curtains, and so on. eingebauten Wasserwärmetauscher verwendet. The mixing unit must be installed in sheltered dry indoor areas Der Mischknoten muss in inneren, verdeckten und trockenen with the temperature of surrounding air from +5 °C to +50 °C. Räumen mit einer Umgebungstemperatur von +5 °C bis +50 °C Temperature of conveyed water shall range between 0 °C and instaliert sein. +110 °C and pressure shall not exceed 1.0 MPa. Das geförderte Wasser muss die Temperatur im Bereich 0 °C The mixing unit has been designed for the regulation of heating bis +110 °C und den Druck maximal 1,0 MPa haben. water complying with the VDI 2035. Water being regulated must Der Mischknoten ist für die Regelung des Heizwassers nach VDI not contain any solid particles (sand, mud) or chemicals because 2035 bestimmt. Das geregelte Wasser darf keine festen Partikel solid particles or chemicals might damage the mixing unit. (Sand, Schlamm) und auch keine Chemikalien beinhalten, da The mixing unit’s servo-actuator has the IP 40 protection (pro- diese den Mischknoten beschädigen könnten. tection against solid bodies greater than 1 mm not protected Die Schutzklasse des Stellantriebs ist IP 40 (Schutz gegen against water!).

Open the catalog to page 1
SMU 2 - 2

PRIMARY PARAMETERS WICHTIGSTE PARAMETER water circulates in the heat exchanger circuit. das Heizwasser läuft in dem Kreislauf des Wärmetauschers vs Shunt ball valve Kugelhahn des Kurzschlusses Regulation by mixing Regelung durch Vermischung Thermometer Throttle valve Drosselarmatur Ball valve Kugelhahn Filter Ball valve Kugelhahn not included in the delivery kein Bestandteil der Lieferung Mixing valve Mischarmatur Throttle valve size Shunt dimensions * Outter / Außengewinde ** Inner / Innengewinde Servo-actuator parameters Parameter des Servoantriebs Kvs Power supply Versorgung [V/Hz]...

Open the catalog to page 2
SMU 2 - 3

The dimensions are in mm / Abmessungen sind in mm angeführt Armature characteristics

Open the catalog to page 3
SMU 2 - 4

SMU 2 Armature characteristics Charakteristik der Armatur The k„s value indicates the flow through the valve in m3/hour, with the valve in the fully open state, at the valve pressure loss of 100 kPa. Wert kvs entspricht dem Durchfluss durch Ventil in m3/Stunde. Beim vollen Offnen und Druckverlust am Ventil 100 kPa. - The mixing unit may be installed in any position. - The mixing unit shall be connected to the heat exchanger's tubes by means of the flexible hoses. - Installation of the mixing unit shall allow a sufficient access when performing maintenance, servicing or dismounting. - For...

Open the catalog to page 4
SMU 2 - 5

REQUIRED ACCESSORIES ERFORDERLICHES ZUBEHÖR If the mixing unit is not connected directly to a device that will Sofern der Mischknoten nicht direkt zur Anlage, die deren perform the necessary control functions, it shall be controlled Steuerung sicherstellt angeschlossen ist, muss dieser mit einem separaten Regler gesteuert werden. WIRING DIAGRAMS ELEKTRISCHE SCHALTPLÄNE The recommended cross-section of the main power supply Empfohlene min. Dimensionierung der Leiter von der Hauptzu- ables is stated in the Instruction Manual. leitung der el. Energie ist in der Anleitung dargestellt. All...

Open the catalog to page 5

All 2VV s.r.o. catalogs and technical brochures

  1. AIR CURTAINS

    7 Pages

  2. SAVANA EC

    12 Pages

  3. 2VV Brochure

    19 Pages

  4. VIREX AIR

    4 Pages

  5. FINESSE EC

    14 Pages

  6. INDESSE EC

    20 Pages

  7. INDESSE GP

    18 Pages

  8. ENTRESSE

    10 Pages

  9. ALFA 95 FLAT

    19 Pages

  10. STANDESSE XP

    8 Pages

  11. STANDESSE XP

    15 Pages

  12. ALFA EC

    39 Pages

  13. INDESSE EC

    19 Pages

  14. VENESSE

    12 Pages

  15. BASIC

    7 Pages

  16. INDESSE GP

    17 Pages

  17. FINESSE

    14 Pages

  18. INDESSE GP

    5 Pages

  19. SAVANA

    11 Pages

  20. VENUS

    13 Pages

  21. WHISPER AIR

    17 Pages

  22. ALFA 95 FLAT

    18 Pages

  23. ALFA 95

    29 Pages

  24. INDESSE

    19 Pages

  25. standesse

    21 Pages

  26. ESSENSSE NEO

    20 Pages

  27. SAVANA

    2 Pages

  28. INDESSE GP

    4 Pages

  29. WHISPER AIR

    4 Pages

  30. FINESSE

    18 Pages

  31. B A S I C

    5 Pages

Archived catalogs

  1. OE-M

    6 Pages

  2. OSMU

    3 Pages

  3. TV1/1

    3 Pages

  4. ZV3

    4 Pages

  5. ROV

    3 Pages

  6. VULKAN / N

    5 Pages

  7. EOKO

    11 Pages

  8. VOK / 01

    4 Pages

  9. KRTK/A

    2 Pages

  10. RSKR/Z

    2 Pages

  11. RSKT/Z

    2 Pages

  12. ESSENSSE

    13 Pages