video corpo
cad

ZV3
1 /4Pages

ZV3

ZV3
1 /4Pages

Catalog excerpts

ZV3-1

The ZV-3 zone valve is designed for controlling the heat output of water-type heat exchangers. It is used especially for controlling standalone water-type air heaters, heaters inbuilt into the ventilation units, heaters in air curtains, and so on. Das Zonenventil ZV-3 ist zur Regelung der Warmeleistung des Wasserwarmetauschers bestimmt. Wird besonders fur die Regelung separater in den Belilftungsgeraten und Luftschleiern eingebauten Wasserwarmetauscher verwendet. The zone valve shall be installed in sheltered dry indoor areas with the ambient temperature of +5 °C up to +60 °C. Temperature of water being controlled shall range between 0 °C and +110 °C and pressure shall not exceed 1.0 MPa. The zone valve is designed for controlling the heating water in accordance with VDI 2035. Water being controlled shall not contain any solid particles (sand, mud) or any chemicals. The electric IP rating of the zone valve is IP 40 (protection against solid particles greater than 1 mm not protected against water!). The zone valve comprises a three-way valve and a servo drive. Das Zonenventil muss in inneren, verdeckten und trockenen Raumen mit einer Umgebungstemperatur von +5 °C bis +60 °C instaliert sein. Das geregelte Wasser muss die Temperatur im Bereich 0 °C bis + 110 °C und den Druck maximal 1,0 MPa haben. Das Zonenventil ist fur die Regelung des Heizwassers nach VDI 2035 bestimmt. Das geregelte Wasser darf keine festen Partikel (Sand, Schlamm) und auch keine Chemikalien beinhalten. Die Schutzklasse des Zonenventils mit Stellantrieb ist IP 40 (Schutz gegen groBere Partikel, als 1 mm, nicht geschtitzt gegen Wasser!) Das Zonenventil besteht aus einer Dreiwegarmatur und einem Stellantrieb. PRIMARY PARAMETERS

 Open the catalog to page 1
ZV3-2

The power cord length is 650 mm. Armature characteristics

 Open the catalog to page 2
ZV3-3

– The zone valve may be installed in any position. when performing maintenance, servicing or dismounting. – The electric cables shall not touch the surface of the zone valve. garantiert wird - mixing unit. nenventils berühren – bis in die Entfernung von 100 mm vom Mischknoten dürfen The zone valve is controlled by connecting phase to appropriate sprechende Klemme betätigt. Das Ventil schaltet zwischen zwei möglichen Strömungswegen des Heizmediums siehe Abb. thus be used for controlling the valve. Thermostat zu verwenden.

 Open the catalog to page 3
ZV3-4

REQUIRED ACCESSORIES ERFORDERLICHES ZUBEHÖR No special accessories are required to ensure a proper operation of the zone valve. OPTIONAL ACCESSORIES WÄHLBARES ZUBEHÖR Room thermostat WIRING DIAGRAMS ELEKTRISCHE SCHALTPLÄNE All wiring diagrams provided in the technical catalog are Sämtliche im technischen Katalog angeführten Schaltplä- indicative only. When assembling the product, observe ne sind nur informativ. Bei der Montage des Produktes strictly the nameplate ratings as well as directions and richten Sie sich ausschließlich nach den Schildwerten und Schaltbildern, die entweder auf dem Produkt...

 Open the catalog to page 4

All 2VV s.r.o. catalogs and technical brochures

  1. AIR CURTAINS

    7  Pages

  2. SAVANA EC

    12  Pages

  3. 2VV Brochure

    19  Pages

  4. VIREX AIR

    4  Pages

  5. FINESSE EC

    14  Pages

  6. ENTRESSE

    10  Pages

  7. ALFA 95 FLAT

    19  Pages

  8. STANDESSE XP

    8  Pages

  9. ALFA EC

    39  Pages

  10. INDESSE EC

    19  Pages

  11. VENESSE

    12  Pages

  12. BASIC

    7  Pages

  13. INDESSE GP VCIN

    17  Pages

  14. FINESSE

    14  Pages

  15. SAVANA

    11  Pages

  16. VENUS

    13  Pages

  17. WHISPER AIR

    17  Pages

  18. ALFA 95

    29  Pages

  19. INDESSE

    19  Pages

  20. standesse

    21  Pages

  21. ESSENSSE NEO

    20  Pages

  22. SAVANA

    2  Pages

  23. WHISPER AIR

    4  Pages

  24. V E N E S S E

    9  Pages

  25. FINESSE

    18  Pages

  26. B A S I C

    5  Pages

Archived catalogs

  1. ESSENSSE

    13  Pages

  2. RSKT/Z

    2  Pages

  3. EOKO

    11  Pages

  4. KRTK/A

    2  Pages

  5. RSKR/Z

    2  Pages

  6. VOK / 01

    4  Pages

  7. ROV

    3  Pages

  8. VULKAN / N

    5  Pages

  9. TV1/1

    3  Pages

  10. SMU 2

    5  Pages

  11. OSMU

    3  Pages

  12. OE-M

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.