ALFA 95 FLAT | HRFL HEAT RECOVERY Counterflow plate heat recovery exchanger BASIC FEATURES ALFA 95 FLAT Highly efficient under-ceiling heat recovery unit designed for applications in commercial interiors, such as shops, offices, coffee bars, restaurants and sport facilities. – 4 sizes with air flows: 400, 700, 1500 and 2000 m3/h – Ecodesign directive 1253/2014 compliant – All sizes complies with criteria for Passive House Component certification – Sizes 700, 1500 and 2000m3/h are certified components by the Passive House Institute – Aluminium counterflow exchanger with heat recovery efficiency of up to 93 % (EN308) – Energy-efficient EC fans with low SFP and quiet operation – Compact size with low installation height – Integrated electric pre-heater (optional) – Integrated electric/water after-heater, modular C/O or DX coils concept (optional) –A irGENIO Superior control system with an option of CAV, VAV or DCV mode, other supplementary modes, antifreeze protection, BMS control via ModBUS RTU, TCP or BACnet. ALFA 95 FLAT heat recovery unit is designed to be operated in a dry indoor environment (relative humidity not exceeding 80 %) and at an ambient temperature in the range from +5 °C up to +60 °C. The unit is designed for transporting standard atmospheric air that is free of dust, grease, chemical emissions and other impurities. The transported air relative humidity must not exceed 90 %. The casing of the unit is made from sandwich panels. When unit installed in the duct system its IP rating is 20. The design of the ventilation project must be always designed by a qualified HVAC designer, engineer
Open the catalog to page 1Operational diagram Funktionsschema ALFA 95 FLAT | HRFL HEAT RECOVERY Operational diagram Operational diagram ODA Funktionsschema Fan / Ventilator Heat exchanger / Wärmetauscher Filter / Filter Regulation / die Regulation Condesate exhaust / Kondensatausscheidung Afterheater / Nachheizeinrichtung / DX / CO By-pass flap / By-pass Klappe Preheater / Vorwärmer 1 Fan / Ventilator Heat exchanger / Wärmetauscher Filter / Filter Regulation / die Regulation Condesate exhaust / Kondensatausscheidung Afterheater / Nachheizeinrichtung / DX / CO By-pass flap / By-pass Klappe Preheater / Vorwärmer...
Open the catalog to page 2ALFA 95 FLAT | HRFL HEAT RECOVERY PRIMARY PARAMETERS SFP=Unit Power input/supply airflow (kW/m3/s)
Open the catalog to page 3ALFA 95 FLAT | HRFL HEAT RECOVERY PRIMARY PARAMETERS SFP=Unit Power input/supply airflow (kW/m3/s)
Open the catalog to page 4ALFA 95 FLAT | HRFL HEAT RECOVERY Noise specifications: HRFL2-040 Sound power level per frequency band Airflow [m³/h] Sound power level per frequency band Branch HRFL2-070 Sound power level per frequency band Airflow [m³/h] Sound power level per frequency band Branch
Open the catalog to page 5ALFA 95 FLAT | HRFL HEAT RECOVERY Noise specifications: HRFL2-150 Sound power level per frequency band Airflow [m³/h] Sound power level per frequency band Branch HRFL2-200 Sound power level per frequency band Airflow [m³/h] Sound power level per frequency band Branch
Open the catalog to page 6ALFA 95 FLAT | HRFL HEAT RECOVERY Basic technical parameters of the heat recovery units: Model without electric pre-heater: Model without coil / with water heating coil / C-O coil / DX coil Type Model with electric coil (post-heater) Model with electric pre-heater: Model without coil / with water heating coil / with change-over coil Type Model with electric preheater (post-heater) Type Type Without reheating With electric reheating With water reheating
Open the catalog to page 7ALFA 95 FLAT | HRFL HEAT RECOVERY Characteristics of electric motors (1 fan only) Speed [r/min] Insulation class Characteristics of electric coil Type Characteristics of electric preheater Characteristics of water heating coil Type Water pressure loss [kPa] Connection diameter * For water temperature gradient 90/70 and inlet air temperature 15°C. Correction coefficients of the powers of the hot water coil* Air inlet temperature [°C] * To apply to the rated power in the characteristics of the LPH
Open the catalog to page 8ALFA 95 FLAT | HRFL HEAT RECOVERY Characteristics of water cooling / heating coil (C/O) Type Water pressure loss [kPa] Connection diameter *F or water temperature gradient 60/40 and inlet air temperature 15°C. Characteristics of water cooling / heating coil (C/O) Type Water pressure loss [kPa] Connection diameter *F or water temperature gradient 7/12 and inlet air temperature 25°C with 70% of relative humidity. Correction coefficients of the powers of the hot water coil (C/O)* Air inlet temperature [°C] 0 5 10 15 20 * To apply to the rated power in the characteristics of the water coil....
Open the catalog to page 9ALFA 95 FLAT | HRFL HEAT RECOVERY Characteristics of direct evaporator (DX) Refrigerant R32 Type Refrigerant pressure loss [kPa] Connection diameter of gas coil Connection diameter of liquid coil * For inlet air temperature 25°C with 47% of relative humidity and evaporation temperature 5°C, refrigerant R32. Refrigerant pressure loss [kPa] Connection diameter of gas coil Connection diameter of liquid coil * For inlet air temperature 25°C with 47% of relative humidity and evaporation temperature 5°C, refrigerant R410A. INSTALLATION AND ASSEMBLY ALFA FLAT units must be installed according to...
Open the catalog to page 10ALFA 95 FLAT | HRFL OUTDOOR ENVIROMENT OUTDOOR ENVIROMENT INDOOR ENVIROMENT ABAB AAAA INDOOR ENVIROMENT OUTDOOR ENVIROMENT INDOOR ENVIROMENT
Open the catalog to page 11HEAT RECOVERY ALFA 95 FLAT | HRFL WIRING DIAGRAMS SAFETY THERMOSTAT POSTHEATING SAFETY PREHEATING THERMOSTAT LF1 - FLAP INLET (output L-open), LF2 - FLAP OUTLET ( output L-open) RUN CONTACT (output - NO/NC settable) ERROR CONTACT (output NO) PREHEATER WATER PUMP (11 - Lint, 12 - Lout) EXTERNAL CONTROL ON/OFF (input NC) OUTPUT PERFORMANCE OF POSTHEATING (0-10V OR PWM) WATER PUMP (1 - Lint, 2 - Lout) HEAT PUMP CONTROL settable (output - ON/OFF) ADIABATIC MODULE (output - ON/OFF) COOL / HEAT settable (CO = NC/NO - DX = output settable) ADIABATIC MODULE ERROR (input NO) HEAT PUMP DEFROST...
Open the catalog to page 12ALFA 95 FLAT | HRFL HEAT RECOVERY AirGENIO SUPERIOR - Main control functions • Touch-screen control panel for easy control and complete overview of device operational status (recommended connecting data cable to control panel is UTP cable and it should not exceed 50m length). • Manual stepless fans control (PWM) • CAV, VAV or DCV ventilation in automatic mode • BOOST mode - intensive airflow for a pre-set time period • Freecooling mode - night ventilation (cooling) • Occupancy mode - reducing ventilation intensity according to the PIR sensor • FIRE protection mode with settable logic •...
Open the catalog to page 13All 2VV s.r.o. catalogs and technical brochures
-
TECHNICAL CATALOG 2022
619 Pages
-
AIR CURTAINS
7 Pages
-
SAVANA EC
12 Pages
-
2VV Brochure
19 Pages
-
VIREX AIR
4 Pages
-
FINESSE EC
14 Pages
-
INDESSE GP
18 Pages
-
ENTRESSE
10 Pages
-
ALFA 95 FLAT
19 Pages
-
HEAT RECOVERY UNITS
7 Pages
-
STANDESSE XP
8 Pages
-
STANDESSE XP VCST5D
15 Pages
-
ALFA EC
39 Pages
-
INDESSE EC
19 Pages
-
VENESSE
12 Pages
-
BASIC
7 Pages
-
INDESSE GP VCIN
17 Pages
-
FINESSE
14 Pages
-
E S S E N S S E NEO
13 Pages
-
INDESSE GP
5 Pages
-
SAVANA
11 Pages
-
VENUS
13 Pages
-
WHISPER AIR
17 Pages
-
ALFA 95
29 Pages
-
INDESSE
19 Pages
-
standesse
21 Pages
-
ESSENSSE NEO
20 Pages
-
SAVANA
2 Pages
-
ESSENSSE NEO EC
2 Pages
-
INDESSE GP
4 Pages
-
WHISPER AIR
4 Pages
-
V E N E S S E
9 Pages
-
FINESSE
18 Pages
-
S TA N D E S S E
16 Pages
-
B A S I C
5 Pages
Archived catalogs
-
OE-M
6 Pages
-
OSMU
3 Pages
-
SMU 2
5 Pages
-
TV1/1
3 Pages
-
ZV3
4 Pages
-
ROV
3 Pages
-
VULKAN / N
5 Pages
-
CLASSIC / CLC-P
3 Pages
-
VULKAN / VKN-P
4 Pages
-
EOKO
11 Pages
-
VOK / 01
4 Pages
-
KRTK/A
2 Pages
-
RSKR/Z
2 Pages
-
RSKT/Z
2 Pages
-
ESSENSSE
13 Pages