カタログの抜粋

P6000 SYSTEM DESCRIPTION COMMUNICATION IN HOSPITALS AND NURSING HOMES
カタログの1ページ目を開く
CONTENTS DESCRIPTION -------------------------------------------------------------------------------------------------------------------------3 ROOM CONFIGURATIONS --------------------------------------------------------------------------------------------------------4 CALL TYPES – OPERATION 1 - Voice communication systems between the control station and the rooms, and between the nurse in a room and other rooms. Functions: setting presence, making and cancelling calls. NORMAL CALL...
カタログの2ページ目を開く
from the control point to all rooms or one room in particular. without unnecessary staff movement.
カタログの3ページ目を開く
ROOM CONFIGURATIONS where there is a nurse. This means that the diately answer the patient/resident from the the patient. It avoids the unnecessary movephysical presence of a nurse. point to all rooms or one room in particular. answer calls made from another room. This without unnecessary staff movement. nurse in the room of calls made from another
カタログの4ページ目を開く
CALL TYPES - OPERATION 1. Voice communication systems between the nurse control station and the rooms, and between the nurse in a room and other rooms. Functions: Setting presence, making of cancelling calls. Normal call Rooms with set presence -
カタログの5ページ目を開く
cancelling from any room with a nurse present where the call was made. cancelling from the room itself
カタログの6ページ目を開く
Bathroom call Rooms with set presence
カタログの7ページ目を開く
Emergency or help call Rooms with set presence Cancelling the call from where the call was made
カタログの8ページ目を開く
2. Voice communication systems between the nurse control station and the rooms. Functions: Setting presence, making of cancelling calls. Normal call Rooms with set presence
カタログの9ページ目を開く
Bathroom call
カタログの10ページ目を開く
Rooms with set presence Emergency or help call
カタログの11ページ目を開く
Rooms with set presence
カタログの12ページ目を開く
3. Systems for setting presence, making and cancelling calls (without voice communication) Normal call Rooms with set presence
カタログの13ページ目を開く
Bathroom call Rooms with set presence
カタログの14ページ目を開く
Emergency or help call Rooms with set presence
カタログの15ページ目を開く
Disconnection call
カタログの16ページ目を開く
MODULES CONTROL PH6000 - Control station Colour: Dimensions: Installation: Box with 60 mm distance between axes. Colour: White Front plate: KCP9300-01 or KCP9302-01 (double) from Sonelco. P3262 - Power supply Installation: DIN rail (9 units). Dimensions: 155 x 85 x 58 mm
カタログの17ページ目を開く
ROOMS PH6011 - Electronic room and lighting control module Installation: 4901 box from Sonelco. Dimensions: 120*62*44 mm Colour: White Front plate: KM 9200-01. Dimensions 152*80 mm PH6010 - Electronic room control module PCH6025 - Call/cancel module with display shows the source and type of call. Allows a nurse in the room to see if there is Installation: Box with 60 mm distance between axes. Colour: White Front plate: KCP9300-01 or KCP9302-01 (double) from Sonelco PCH6020 - Call/cancel module without display Installation: Box with 60 mm distance between axes. Colour: White Front plate:...
カタログの18ページ目を開く
PCH6022 - Module with microphone/speaker Installed where an intercom system is desired. The patient is allowed to respond Installation: Box with 60 mm distance between axes. Colour: White Front plate: KCP9300-01 or KCP9302-01 (double) from Sonelco PCH6021 - Intercom control module Installation: Box with 60 mm distance between axes. Colour: White Front plate: KCP9300-01 or KCP9302-01 (double) from Sonelco PCH6030 - Nurse call device with a plug to connect a “pear” button Installation: Box with 60 mm distance between axes. Colour: White Front plate: KCP9300-01 or KCP9302-01 (double) from...
カタログの19ページ目を開く
PCH6040 - Bath call cord Installation: Box with 60 mm distance between axes. Colour: White Front plate: KCP9300-01 or KCP9302-01 (double) from Sonelco PCH6050 - Call cancellation module Installation: Box with 60 mm distance between axes. Colour: White Front plate: KCP9300-01 or KCP9302-01 (double) from Sonelco
カタログの20ページ目を開く
A SYSTEM WITH GREAT BENEFITS EASY INSTALLATION - ROOM MODULES IN A UNIVERSAL BOX COMBINATION WITH ELECTRONIC MECHANISMS EASY MAINTENANCE control station and connect it. the data from the electronic room modules. EASY, TIME-SAVING OPERATION INCREASED PATIENT COMFORT
カタログの21ページ目を開く
INSTALLATION EXAMPLES The modules installed depend on the performance features required. Below are some examples with the necessary components: 1.1 Installation example: Voice communication between the control station and rooms, as well as the nurse present in a room and the rest of the rooms Setting presence, making and cancelling a call With display Control: Equipment per room Electronic room control module: Set of control elements for health personnel: Patient call devices (room with 2 beds and a bathroom):
カタログの22ページ目を開く
1.2 Installation example: Voice communication between the control station and rooms, as well as the nurse present in a room and the rest of the rooms Setting presence, making and cancelling a call Control: Equipment per room Electronic room control module: Set of control elements for health personnel: Patient call devices (room with 2 beds and a bathroom):
カタログの23ページ目を開く
2.1 Installation example: Voice communication between the control station and rooms Setting presence, making and cancelling a call With display Control: Equipment per room Electronic room control module: Set of control elements for health personnel: Patient call devices (room with 2 beds and a bathroom):
カタログの24ページ目を開く
2.2 Installation example: Voice communication between the control station and rooms Setting presence, making and cancelling a call Control: Equipment per room Electronic room control module: Set of control elements for health personnel: Patient call devices (room with 2 beds and a bathroom):
カタログの25ページ目を開く
3.1 Installation example: Setting presence, making and cancelling a call With display Control: Equipment per room Electronic room control module: Set of control elements for health personnel: Patient call devices (room with 2 beds and a bathroom):
カタログの26ページ目を開く
3.2 Installation example: Setting presence, making and cancelling a call Control: Equipment per room Electronic room control module: Set of control elements for health personnel: Patient call devices (room with 2 beds and a bathroom):
カタログの27ページ目を開く
Sistemas de comunicación y sonido, S.A.L. Pol. El Portazgo, nave 62B Autovía de Logroño, Km 2,4 50011 ZARAGOZA - Spain Tels. ++34 976 259 125 - Fax: ++34 976 373 775 Email: export@sonelco.com www.sonelco.com