Carisma Fly - Fly-ECM
1 / 40ページ

カタログの抜粋

Carisma Fly - Fly-ECM - 1

www.eurovent-certification.com www.certiflash.com High Wall Fan Coil Carisma Fly Carisma Fly-E

カタログの1ページ目を開く
Carisma Fly - Fly-ECM - 2

CVP Serie • Versions and Main Components • Dimension, Weight, Water content • EUROVENT certifications • Working conditions • Emissions • Water side pressure drop • Accessories • Control operations • Wall electronic controls • Electronic control accessories • Controls and units CVP-ECM Serie • Versions and Main Components • Dimension, Weight, Water content • EUROVENT certifications • Working conditions • Emissions • Models with electric heater • Water side pressure drop • Accessories • Fly ECM configuration • Controls and units T and MB versions CVP / CVP-ECM Serie • Controls and units T...

カタログの2ページ目を開く
Carisma Fly - Fly-ECM - 3

Carisma Fly CVP Serie SABIANA Fly MODELS WITHOUT ELECTRIC HEATER - All versions are available without valves, with 2 way valve or with 3 way valve fitted in the unit. There are four sizes available in the following versions: CVP without infra-red remote control and without valve CVP-2V without infra-red remote control with fitted 2 way valve CVP-3V without infra-red remote control with fitted 3 way valve CVP-T with infra-red remote control and without valve CVP-T-2V with infra-red remote control with fitted 2 way valve CVP-T-3V with infra-red remote control with fitted 3 way valve CVP-MB...

カタログの3ページ目を開く
Carisma Fly - Fly-ECM - 4

Dimension, Weight, Water content Carisma Fly COIL CONNECTIONS ON THE LEFT MOUNTING DIMENSION

カタログの4ページ目を開く
Carisma Fly - Fly-ECM - 6

Carisma Fly CVP Serie SABIANA Technical features wwweurovent-certification.com www.certiflash.com HEATING (winter operation) Entering air temperature: + 20°C Water temperature: + 50°C E.W.T. Water flow rate as for the cooling conditions The following standard rating conditions are used: COOLING (summer operation) Entering air temperature: + 27°C d.b. / + 19°C w.b. Water temperature: + 7°C E.W.T. / + 12°C L.W.T. (E) = Eurovent certified performance. MIN-MED-MAX = Standard connected speeds. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the...

カタログの6ページ目を開く
Carisma Fly - Fly-ECM - 7

Carisma Fly CVP Serie SABIANA WORKING CONDITIONS - + 70 °C .. + 6 °C contact “SABIANA” technical department ..1000 kPa (10 bars)

カタログの7ページ目を開く
Carisma Fly - Fly-ECM - 8

CVP Serie Emissions_ Carisma Fly IL CLIMA AMICO Entering air temperature: +27°C - Relative Humidity: 50% WT = Water temperature Speed Pc = Cooling Total emission MAX Ps = Cooling Sensible emission MED Legend = Fan speed = High speed = Medium speed = Low speed = Air flow pressure drop

カタログの8ページ目を開く
Carisma Fly - Fly-ECM - 9

CVP Serie Emissions_ Carisma Fly ^3 Fan speed High speed Medium speed Low speed Air flow Legend WT = Water temperature Speed Pc = Cooling Total emission MED Ps = Cooling Sensible emission MIN Dp(c) = Water side pressure drop

カタログの9ページ目を開く
Carisma Fly - Fly-ECM - 10

Fly MODELS WITH ELECTRIC HEATER All versions are available without valves, with 2 way valve or with 3 way valve fitted in the unit. There are four sizes available in the following versions: CVP-E without infra-red remote control and without valve CVP-E-2V without infra-red remote control with fitted 2 way valve CVP-E-3V without infra-red remote control with fitted 3 way valve CVP-T-E with infra-red remote control and without valve CVP-T-E-2V with infra-red remote control with fitted 2 way valve CVP-T-E-3V with infra-red remote control with fitted 3 way valve CVP-MB-E with MB electronic...

カタログの10ページ目を開く
Carisma Fly - Fly-ECM - 11

Water side pressure drop CVP Serie Carisma FlyCoil pressure drop Dp Valves pressure drop Kvs 2,5 Pressure drop for mean water temperature of 10°C; for different temperatures multiply the pressure drop figure by the K correction factors in the table.

カタログの11ページ目を開く
Carisma Fly - Fly-ECM - 12

Electrical diagrams are shown on the installation, use and maintenance manual WM-3V 9066642 Manual 3 speed switch. Without thermostatic control. It can not control the valves.

カタログの12ページ目を開く
Carisma Fly - Fly-ECM - 13

CVP CVP Serie Wall electronic controls ID ON-OFF switch. Manual 3 speed switch. Manual Summer/Winter switch. Electronic room thermostat for fan control (ON-OFF). Electronic room thermostat for valve control (ON-OFF) (the fan keeps working). • It allows to control the low temperature cut-out thermostat (TMM). • It allows to control the chilled water valve (ON-OFF) and the electric heater (BEL). Dimensions: 135x86x31 mm ON-OFF switch. Manual 3 speed switch. Manual Summer/Winter switch. Electric heater activation button. Electronic room thermostat for fan control (ON-OFF). Electronic room...

カタログの13ページ目を開く
Carisma Fly - Fly-ECM - 14

Carisma Fly CVP Serie SABIANA Speed switches - CVP version - • Speed switch (slave). • It allows to control up to 8 units with only one centralized thermostat using one speed switch for each unit. • For controls: WM-T, WM-TQR and TMO-503-SV2.

カタログの14ページ目を開く
Carisma Fly - Fly-ECM - 15

NTC low temperature cut-out thermostat ID Code To be fitted between the coil fins. When connecting the control, the NTC probe cable must be separated from the power supply wires. To be used with the following controls: WM-TQR. It stops the fan when the water temperature is lower than 28°C and it starts the fan when is higher than 33°C. TMM low temperature cut-out thermostat — ID Code TMM 9053048 To be installed in contact with the hot water circuit. To be used with the following controls only: WM-T. For units working on heating only. It stops the fan when the water temperature is lower than...

カタログの15ページ目を開く
Carisma Fly - Fly-ECM - 16

Controls and units T and MB versions All the CVP units can be supplied in T version and in MB version. • The T version includes the infra-red remote control that allows the management of a single unit (the units can not be controlled in a network). • The MB version includes a wide range of controls, including the infra-red remote control (optional extra), which allows to manage one single unit or several units by using the Modbus RTU - RS 485 communication protocol. Units can be managed according to the Master/Slave logic (up to 20 units) or by supervisory controls. The system consists in a...

カタログの16ページ目を開く
Carisma Fly - Fly-ECM - 17

All versions are available without valves, with 2 way valve or with 3 way valve fitted in the unit. There are four sizes available in the following versions: CVP-ECM without infra-red remote control and without valve CVP-ECM-2V without infra-red remote control with fitted 2 way valve CVP-ECM-3V without infra-red remote control with fitted 3 way valve CVP-ECM-T with infra-red remote control and without valve CVP-ECM-T-2V with infra-red remote control with fitted 2 way valve CVP-ECM-T-3V with infra-red remote control with fitted 3 way valve CVP-ECM-MB with MB electronic board and without...

カタログの17ページ目を開く

Sabianaのすべてのカタログと技術パンフレット

  1. Atlas

    7 ページ

  2. Cool Breeze

    6 ページ

  3. PULSAR

    9 ページ

  4. Duck Strip

    11 ページ

  5. PRODUCT RANGE 2020

    446 ページ

  6. PRODUCT RANGE 2019

    436 ページ

  7. InoxSabiana 50

    5 ページ

  8. CARISMA COLLECTION

    28 ページ

  9. Duck Strip 4.1

    28 ページ

  10. Polaris

    5 ページ

  11. Product Range 2013

    316 ページ

  12. Product Range

    40 ページ

カタログアーカイブ

  1. DUCK STRIP

    12 ページ

  2. MISTRAL

    2 ページ

  3. SLIM

    4 ページ

  4. SKYSTAR

    5 ページ

  5. FUTURA FSC

    4 ページ

  6. PULSAR

    6 ページ

  7. ELEGANT

    4 ページ

  8. HELIOS

    3 ページ

  9. ATLAS

    4 ページ